DOI QR코드

DOI QR Code

Efficient Removal of Arsenic Using Magnetic Multi-Granule Nanoclusters

  • Lee, Seung-Ho (Interdisciplinary Program in Nanoscience and Technology, Seoul National University) ;
  • Cha, Jinmyung (Department of Chemistry, Seoul National University) ;
  • Sim, Kyunjong (Department of Chemistry, Seoul National University) ;
  • Lee, Jin-Kyu (Department of Chemistry, Seoul National University)
  • Received : 2013.12.04
  • Accepted : 2013.12.09
  • Published : 2014.02.20

Abstract

Magnetic multi-granule nanoclusters (MGNCs) were investigated as an inexpensive means to effectively remove arsenic from aqueous environment, particularly groundwater sources consumed by humans. Various size MGNCs were examined to determine both their capacity and efficiency for arsenic adsorption for different initial arsenic concentrations. The MGNCs showed highly efficient arsenic adsorption characteristics, thereby meeting the allowable safety limit of $10{\mu}g/L$ (ppb), prescribed by the World Health Organization (WHO), and confirming that 0.4 g and 0.6 g of MGNCs were sufficient to remove 0.5 mg/L and 1.0 mg/L of arsenate ($AsO_4{^{3-}}$) from water, respectively. Adsorption isotherm models for the MGNCs were used to estimate the adsorption parameters. They showed similar parameters for both the Langmuir and Sips models, confirming that the adsorption process in this work was active at a region of low arsenic concentration. The actual efficiency of arsenate removal was then tested against 1 L of artificial arsenic-contaminated groundwater with an arsenic concentration of 0.6 mg/L in the presence of competing ions. In this case, only 1.0 g of 100 nm MGNCs was sufficient to reduce the arsenic concentrations to below the WHO permissible safety limit for drinking water, without adjusting the pH or temperature, which is highly advantageous for practical field applications.

Keywords

Introduction

Arsenic is highly toxic element known for its deleterious influences on both the environment and human health. High levels of arsenic uptake by humans have led to health problems such as skin-, kidney-, lung-, liver cancer, and neuro-logical damage in the USA, China, Chile, Bangladesh, Taiwan, Mexico, Argentina, Poland, Canada, Hungary, Japan, Nepal, Vietnam, and India. The largest at-risk population to ground-water arsenic pollution is in Bangladesh, followed by the inhabitants of West Bengal in India.1-3 Because of its toxicity and carcinogenic effects on human health, the World Health Organization (WHO) reduced the allowable safety limit of arsenic in drinking water from 50 to 10 μg/L in 1993, and strictly regulated the quality of water.4 The European Union has amended all drinking water supply systems according to this updated limit. The United States Environmental Protection Agency (USEPA) has also adopted the WHO prescribed maximum level of arsenic contamination (10 μg/L) in drinking water; this has been put to effect since 2006.5

There is an urgent need to improve the prevailing water treatment technology because arsenite (AsO2 −) and arsenate (AsO4 3−) are the two predominant arsenic species found in groundwater.6 Adsorption has become an attractive and promising technology for arsenic extraction because of its simplicity, safety, ease of operation, maintenance, and handling, sludge-free operation, potential for regeneration, and possibility for the use of inexpensive adsorbent. In general, it is open considered to be the most effective treatment process for the removal of arsenic from aqueous environments at relatively low costs. Furthermore, to be effective and practical, an arsenic removal method should be easily applicable at individual sites serving households or small communities.7 Various types of iron-based nanoparticle adsorbents have been developed for arsenic removal because of their high affinity for and adsorption capacity of the anionic form of arsenic oxyacids. Some of the representative examples of these types of compounds are Fe3O4@NiO hierarchical nano-structures, 8 ordered meso-porous carbon encapsulating a wide range of metal oxide nanoparticles,9 Fe3O4 and Fe2O3 obtained through a precipitation method,10 and mechanically ball-milled Fe3O4 nanopowder.11

Many methods have been developed to increase the size of magnetite nanoparticles, which would result in a fast response to the external magnetic field particles, while keeping them stably dispersed in solution. To this end, it is sometimes mis-understood that large-sized superpara-magnetic nanoparticles having negligible remanence (residual magnetism) and coercivity (the field required to reduce magnetization to zero) at room temperature is the most effective material. However, this is not the most effective way. We recently reported that ferromagnetic materials could be made more useful when they could be dispersed in the solution by a strong inter-action between solvent molecules and surface functional groups.12 The magnetic saturation (MS) values measured at 70 kOe (300 K) were 73.9, 80.3, and 84.6 emu/g for MGNCs of 100, 200, and 400 nm, respectively. The relatively high MS value of multi-granule nanocluster (MGNC) samples at 100 nm was very close to the reported MS values for Fe3O4 nanoparticles. The zero-field cooling/field cooling (ZFC/FC) measurements clearly showed the ferromagnetic behavior of MGNCs with various diameters. Although the MGNCs used in our experiments are ferromagnetic are very stable in aqueous solution and are homogeneously dispersed because of multi-granule structure resulting an increased numbers of the surface functional groups (−OH). Therefore, it is of interest to use this new type of magnetite in MGNC for arsenic removal application.

In the present research, MGNCs were prepared in a large scale, as reported in our previous work,12 and examined for their capacity to remove the AsO43− anion from water. We find out that contaminated water could be easily remediated with magnetic MGNCs, which could effectively and practically be applied at individual sites serving households or small communities.

 

Experimental

Materials. Iron(III) chloride hexahydrate (FeCl3·6H2O, > 97%, Sigma-Aldrich), sodium arsenate dibasic heptahydrate (Na2HAsO4·7H2O, > 98%, Sigma-Aldrich), sodium acetate anhydrous (NaO2CCH3, > 98.5%, Samchun Chemicals), and ethylene glycol (HOCH2CH2OH, > 99.5%, Samchun Chemi-cals) were purchased and utilized as received. An arsenic stock solution of 100 mg/L was prepared by dissolving appropriate amount of sodium arsenate Na2HAsO4·7H2O in deionized water. Working solutions for each experiment were freshly prepared from the stock solution.

Preparation of MGNCs. MGNCs were prepared by following the procedure published in the literature.12

In a typical MGNC synthesis, FeCl3·6H2O (27 g, 0.1 mol), NaO2CCH3 (100 g, 1.2 mol) and distilled water (100 g, 5.6 mol) were completely dissolved in ethylene glycol (1.5 L) by vigorous mechanical stirring to form a yellowish-brown turbid solution. After heating the solution at 70 °C for various lengths of time, the reaction temperature was increased to the refluxing temperature to complete the reaction, leading to the formation of MGNCs. At this point, the reaction solution turned reddish-brown and then slowly became black. After being cooled down to room temperature, the black sediment was separated magnetically by attaching a strong permanent magnet to the outside of the reaction flask and then washed with ethanol and distilled water several times to eliminate any organic and inorganic byproducts. The specific surface area of magnetic MGNCs was charac-terized using the Brunauer-Emmett-Teller (BET) method by measuring the nitrogen adsorption/desorption surface area (TriStar II 3020, Micromeritics, USA operated at 77 K).

Adsorption Experiments and Analysis. MGNCs having sizes of 100, 200, and 400 nm were used for arsenic removal. Adsorption studies were conducted with aqueous solutions having arsenic concentrations of 0.5 and 1.0 mg/L, which corresponds to the range of arsenic con-centrations in contaminated groundwater. The amounts of the MGNCs used were 0.2, 0.4, 0.6, 0.8, and 1.0 g/L for each size. The solutions of arsenic mixed with MGNCs were shaken in an orbital shaker at 200 rpm, at 298 K for 24 h; the solutions occupied a total volume of 20 mL within the 30 mL glass vial. The MGNCs in the mixture were removed by magnetic decantation with a permanent magnet and the remaining water was evaluated to determine the adsorption capacity. The arsenic concentrations before and after the adsorption experiments were analyzed by means of an inductively coupled plasma-atomic emission spectrometer (ICP-AES, Shimadzu ICPS-7510).

 

Results and Discussion

Characterization of MGNCs. The MGNCs were prepared as previously reported by the simple reaction of FeCl3 and sodium acetate in ethylene glycol, which served as both the solvent and reductant. Simple refluxing in glassware at atmospheric pressure allowed us to easily monitor changes in the color of the reaction mixtures and control the sizes of the MGNCs. The sizes of the MGNC were selected to be 100, 200, and 400 nm for experiments, as shown in Figure 1, because MGNCs with these features exhibited a fast response to the applied external magnetic field after arsenic removal from the aqueous solutions.

The specific surface area of the MGNCs was estimated using the BET method as shown in Table 1. As expected the surface area decreased significantly as the size of MGNC was increased; the surface area for the 400 nm size MGNC was still larger (about 2 times) than that of the bulk (< 5 μm) magnetite powder, confirming the characteristic multi-granular shape of MGNC.

Effect of Initial Arsenic Concentration and Amount of MGNCs of Each Size. The maximum capacity of adsorption can be increased when the initial arsenic concentration is relatively high with respect to the values found in ground-water; however, we measured adsorption capacity at arsenic concentration of 0.5 and 1.0 mg/L because these values are more representative of contaminated groundwater. As shown in Figure 2(a), when the initial concentration of As(V) was 0.5 mg/L, 100 nm MGNC could remove more than 90% of the arsenic at a concentration of 0.2 g/L. At the same initial arsenic concentration and the same size of MGNC, 0.4 g/L of the MGNC (residual arsenic was actually measured as 1 μg/L) was efficient to remove arsenic to satisfy the WHO’s allowable limit of 10 μg/L. When 200 nm MGNC was used, although the adsorption efficiency appeared to be slightly decreased, the WHO’s allowable limit could still be achieved at conditions of 0.4 g/L (residual arsenic was actually mea-sured as 3 μg/L). The largest size MGNC (400 nm), used in the adsorption experiments, showed the lowest arsenic removal efficiency, as expected. At this size, 0.8 g/L MGNC was needed to satisfy the WHO limit. These trends can be explained by the differences in the surface areas of MGNCs as shown in Table 1.

Figure 1.TEM images of MGNCs prepared from the molar ratios of FeCl3:NaOAc:H2O = 0.1:1.2:5.6 in 1.5 L of ethylene glycol after heating at 70 °C for (a) 1 h, (b) 12 h, and (c) 35 h. (scale bar: 400 nm)

Table 1.BET surface areas of various size MGNCs and commercial iron oxide (<5 μm)

Figure 2.As(V) adsorption on magnetic MGNCs of different sizes (100, 200, and 400 nm); Initial arsenic concentration is (a) 0.5 and (b) 1.0 mg/L.

When the initial concentration of As(V) was increased to 1.0 mg/L, a larger amount of MGNCs was needed to remove the arsenic, and the residual arsenic concentrations were measured as 1.5 and 6 μg/L at the conditions of 0.6 g/L of 100 and 200 nm MGNCs, respectively (Fig. 2(b)). However, for 400 nm MGNC, the WHO’s limit could not be achieved even at 1.0 mg/L of the MGNC.

Adsorption Isotherm. Data for the equilibrium arsenate adsorption onto various size MGNCs, as shown in Figure 2, were fitted against the two-parameter Langmuir and Freundlich isotherm models and the three-parameter Sips isotherm model, as shown in Figures 3(a)-3(c). The Langmuir isotherm model assumes that the adsorption occurs at specific homogeneous sites within the adsorbent. This means that once an adsorbate molecule adheres to a site, no additional adsorption can occur at that site.13 We can assume that at low adsorbate concentrations, it effectively reduces to a linear isotherm, and thus obeys Henry’s law. Alternatively, at high adsorbate concentrations, it leads to a constant monolayer sorption capacity.14 The Freundlich isotherm model can be applied to nonideal sorption on heterogeneous surfaces, as well as multilayer sorption. Frequently, the fundamental thermodynamic basis is required because the Freundlich isotherm model does not reduce to Henry’s law at low concentrations.14 The Sips model, also known as the combined Langmuir-Freundlich isotherm, is a three-parameter isotherm model developed to enhance the performance of the individual two-parameter models.15 The Langmuir-Freundlich name originates from the restraining performance of the equation and the resulting model has characteristics of both the contributing models. At low adsorbate concentrations, it effectively reduces to the Freundlich isotherm, and thus does not obey Henry’s law. At high adsorbate concentrations, it predicts the monolayer sorption capacity aspect of the Langmuir isotherm.14

Figure 3.Isotherm plots based on three models for arsenic adsorption on MGNCs of different sizes; (a) 100, (b) 200, and (c) 400 nm.

The mathematical descriptions for the isotherm models are shown as follows: Langmuir (Eq. 1), Freundlich (Eq. 2), and Sips (Eq. 3)

qe is the equilibrium adsorption capacity (mg·g−1);

b is theLangmuir constant related to adsorption intensity (L·mg−1);

Qo is the Langmuir constant reflecting the theoretical maximum adsorption capacity;

Ce is the equilibrium arsenic concentration after adsorption process (mg·L−1);

KF is the Freundlich constant related to adsorption capacity;

n is the Freundlich isotherm exponent;

Qs is the saturated Sips model adsorption capacity;

as is the Sips isotherm constant; and

s is the Sips isotherm exponent.

Table 2.Isotherm equation parameters for arsenic removal by MGNCs

The estimated parameters derived from each isotherm model are summarized in Table 2, with the measured experi-mental data calculated by a non-linear optimization method. The three-parameter Sips model produced a better fit to the experimental data compared to two-parameter isotherm model, as clearly shown by the value of the correlation coefficient (R2). The correlation coefficient for the Sips isotherms models varied from 0.916 to 0.990, showing a good fit of the measured data. Conversely, for the Langmuir and Freundlich models, the parameters were obtained with a relatively low correlation coefficient: R2 = 0.978-0.821 and 0.897-0.967, respectively.

All of the models for the 100 nm MGCN generated very good correlation coefficient values (in the range of 0.928-0.981). Furthermore, the maximum arsenic adsorption capa-city derived from both the Langmuir and Sips models were rather consistent. These values (2.3-2.4 mg As(V)/g MGCNs) were higher than those of previously reported for nano-particle adsorbents such as hematite coated Fe3O4 particles (2.1 mg/g),11 commercial nanomagnetite (0.20 mg/g),16 and magnetite nanoparticles supported on Fe-hydrotalcite (1.3 mg/g).17

The Freundlich isotherm provides an “n” value that is related with adsorption intensity. A high “n” value indicates good adsorption over the entire range of concentrations studied; a low “n” value means that adsorption ability is increased at high concentrations, but is decreased at lower concentrations.16 The “n” values of the MGNCs were 4.3-6.3 for different size MGNCs, which were higher than the “n” values of previously reported nanoparticle adsorbents such as commercial nanomagnetite (1.8),16 magnetic Fe3O4@NiO hierarchical structures (2.2),8 and magnetite-reduced graphene oxide composites (2.9-3.0).18

Based on the results of the arsenic removal experiments and the adsorption isotherm model studies, the MGNCs studied in this work seem to have several advantages including: (i) quick, simple, and straight forward preparation, which can be easily scaled-up for mass production; (ii) neither pH nor temperature dependence that is usually needed during the adsorption process (yet they maintain high adsorption capacity which is beneficial for efficient field applications); and (iii) a simple magnetic separation and recovery system that takes advantage of the strong magnetic property of MGNCs.

Arsenic Removal from Artificial Arsenic-contaminated Groundwater. In order to emphasize the applicability of our new MGNC adsorbent to remove arsenate from the natural system, As(V)-contaminated groundwater was artificially prepared from distilled water spiked with arsenate and other commonly found cations and anions, as previously described in the literatures (Table 3),19,20 and the remediation process was tested. One liter of artificial contaminated groundwater spiked with arsenate (0.6 mg/L) along with the various cations and anions was treated with 1.0 g of 100 nm MGNCs in the Erlenmeyer flask, as shown in Graphical Abstract. The treated water was then separated from the MGNCs by magnetic decantation and the remaining arsenic concentration in the purified water was determined by ICP-AES. The remaining arsenic concentration was lower than 10 μg/L, implying that our MGNCs successfully adsorbed the arsenate from the artificial arsenic-contaminated groundwater to achieve the WHO prescribed safety limit of arsenic concentration in drinking water.

Table 3.Composition of artificial arsenic-contaminated groundwater

 

Conclusions

Ferromagnetic multi-granule nanoclusters which can be synthesized on a large scales with reasonably high magnetic saturation values of 74-85 emu/g and good dispersion pro-perties in water despite their relatively large size in the range of 100-400 nm, were successively employed as new ad-sorbents for removing arsenic contaminant from water. Adsorption equilibrium data were fitted to the Langmuir, Freundlich, and Sips isotherm models and the various resulting parameters were evaluated. The findings of this work are significant because they show that 1 L of artificial arsenic contaminated groundwater (0.6 mg/L of arsenate) could be effectively remediated with 1.0 g of 100 nm MGNCs, which complied with the WHO permissible arsenic limit of 10 μg/L in drinking water. From these results, we expect that mag-netic MGNCs can effectively remove arsenic from contaminated groundwater at a considerably low cost that will make it suitable for application in household- or small-scale water treatment system, after a more precise kinetic investigation of the adsorption processes is conducted.

References

  1. Mohan, D.; Pittman, C. U., Jr. J. Hazard. Mater. 2007, 142, 1. https://doi.org/10.1016/j.jhazmat.2007.01.006
  2. Nguyen, T. V.; Vigneswaran, S.; Ngo, H. H.; Kandasamy, J. J. Hazard. Mater. 2010, 182, 723. https://doi.org/10.1016/j.jhazmat.2010.06.094
  3. Brammer, H.; Ravenscroft, P. Environ. Int. 2009, 35, 647. https://doi.org/10.1016/j.envint.2008.10.004
  4. Guidelines for Drinking-water Quality, 4th ed.; World Health Organization: Geneva, 2011.
  5. Rubel, F., Jr. Removal of Arsenic from Drinking Water by Adsorptive Media; USEPA, 2003.
  6. Ronkart, S. N.; Laurent, V.; Carbonnelle, P.; Mabon, N.; Copin, A.; Barthelemy, J.-P. Chemosphere 2007, 66, 738. https://doi.org/10.1016/j.chemosphere.2006.07.056
  7. Malik, A. H.; Khan, Z. M.; Mahmood, Q.; Nasreen, S.; Bhatti, Z. A. J. Hazard. Mater. 2009, 168, 1. https://doi.org/10.1016/j.jhazmat.2009.02.031
  8. Zhang, S.; Li, J.; Wen, T.; Xu, J.; Wang, X. RSC Adv. 2013, 3, 2754. https://doi.org/10.1039/c2ra22495j
  9. Wu, Z.; Li, W.; Webley, P. A.; Zhao, D. Adv. Mater. 2012, 24, 485. https://doi.org/10.1002/adma.201103789
  10. Steven, L.; Nathan, B.; Jisoo, K.; Parsons, J. G. Microchem. J. 2012, 101.
  11. Simeonidis, K.; Gkinis, T.; Tresintsi, S.; Martinez-Boubeta, C.; Vourlias, G.; Tsiaoussis, I.; Stavropoulos, G.; Mitrakas, M.; Angelakeris, M. Chem. Eng. J. 2011, 168, 1008. https://doi.org/10.1016/j.cej.2011.01.074
  12. Cha, J.; Lee, J. S.; Yoon, S. J.; Kim, Y. K.; Lee, J.-K. RSC Adv. 2013, 3, 3631. https://doi.org/10.1039/c3ra21639j
  13. Kundu, S.; Gupta, A. K. Chem. Eng. J. 2006, 122, 93. https://doi.org/10.1016/j.cej.2006.06.002
  14. Ho, Y. S.; Porter, J. F.; McKay, G. Water, Air, Soil Pollut. 2002, 141, 1. https://doi.org/10.1023/A:1021304828010
  15. Maliyekkal, S. M.; Philip, L.; Pradeep, T. Chem. Eng. J. 2009, 153, 101. https://doi.org/10.1016/j.cej.2009.06.026
  16. Turk, T.; Alp, .; Deveci, H. J. of Environ. Eng. 2010, 136, 399. https://doi.org/10.1061/(ASCE)EE.1943-7870.0000162
  17. Turk, T.; Alp, I. J. Ind. Eng. Chem. 2013, in press http:// dx.doi.org/10.1016/j.jiec.2013.06.002
  18. Chandra, V.; Park, J.; Chun, Y.; Lee, J. W.; Hwang, I.-C.; Kim, K. S. ACS Nano 2010, 4, 3979. https://doi.org/10.1021/nn1008897
  19. Arifin, E.; Cha, J.; Lee, J. K. Bull. Korean Chem. Soc. 2013, 34, 2358. https://doi.org/10.5012/bkcs.2013.34.8.2358
  20. Hug, S. J.; Leupin, O. X.; Berg, M. Environ. Sci. Tech. 2008, 42, 6318. https://doi.org/10.1021/es7028284

Cited by

  1. Magnetic multi-granule nanoclusters: A model system that exhibits universal size effect of magnetic coercivity vol.5, pp.1, 2015, https://doi.org/10.1038/srep12135
  2. Nanoparticles vol.38, pp.8, 2017, https://doi.org/10.1002/bkcs.11187
  3. Novel Nanofluids Based on Magnetite Nanoclusters and Investigation on Their Cluster Size-Dependent Thermal Conductivity vol.122, pp.12, 2014, https://doi.org/10.1021/acs.jpcc.7b12043
  4. Magnetic hetero-structures as prospective sorbents to aid arsenic elimination from life water streams vol.32, pp.1, 2014, https://doi.org/10.1016/j.wsj.2017.05.001
  5. Mechanistic and energetic studies of superparamagnetic iron oxide nanoparticles as a cyclophosphamide anticancer drug nanocarrier: A quantum mechanical approach vol.44, pp.1, 2014, https://doi.org/10.1177/1468678319825689
  6. Preparation and Application of Iron Oxide Nanoclusters vol.5, pp.3, 2014, https://doi.org/10.3390/magnetochemistry5030045
  7. Potentially toxic elements (PTEs) in fillet tissue of common carp (Cyprinus carpio): a systematic review, meta-analysis and risk assessment study vol.40, pp.4, 2014, https://doi.org/10.1080/15569543.2020.1737826