참고문헌
- Boyer AL and Schultheiss T: Effects of dosimetric and clinical uncertainty on complication-free local tumor control. Radiother Oncol 11(1):65-71 (1988) https://doi.org/10.1016/0167-8140(88)90046-1
- Park BD, Jung SH, Park S, et al: Comparison of dose distributions calculated by anisotropic analytical algorithm and pencil beam convolution algorithm at tumors located in liver dome site. Progress in Medical Physics. 23(2):106-113 (2012)
- Robinson D: Inhomogeneity correction and the analytic anisotropic algorithm J Appl Clin Med Phys 9(2):112-122 (2008)
- Gagne IM and Zavgordoni S: Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations. J Appl Clin Med Phys 8(1):33-46 (2007)
- Tillikainen L, Helminnen H, Torsti T, et al: A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media. Phys Med Biol 53(14):3821-3839 (2008) https://doi.org/10.1088/0031-9155/53/14/008
- Vassiliev ON, Wareing TA, Davis IM, et al: Feasibility of a multigroup deterministic solution method for three-dimensional radiotherapy dose calculations.Int J Radiat Oncol Biol Phys 72(1):220-227 (2008) https://doi.org/10.1016/j.ijrobp.2008.04.057
- Vassiliev ON, Wareing TA, McGhee J, Failla G, Salehpour MR, Mourtada F: Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams. Phys Med Biol 55(3):581-598 (2010) https://doi.org/10.1088/0031-9155/55/3/002
- Gifford KA, Horton JL, Jr., Wareing TA, Failla G, Mourtada F: Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations. Phys Med Biol 51(9):2253-2265 (2006) https://doi.org/10.1088/0031-9155/51/9/010
- Han T, Mikell JK, Salehpour M, Mourtada F: Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media. Med Phys 38(5):2651-2664 (2011) https://doi.org/10.1118/1.3582690
- Bush K, Gagne IM, Zavgorodni S, Ansbacher W, Beckham W: Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations Med Phys 38(4):2208-2221 (2011) https://doi.org/10.1118/1.3567146
- Kan WK, Leung L, Yu P: Verification and dosimetric impact of Acuros XB algorithm on intensity modulated stereotactic radiotherapy for locally persistent nasopharyngeal carcinoma. Med Phys 39(8):4705-4714 (2012) https://doi.org/10.1118/1.4736819
- Fogliata A, Nicolini G, Clivio A, Vanetti E, Cozzi L. Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media. Radiation Oncology 6:82 (2011) https://doi.org/10.1186/1748-717X-6-82
- Esch AV, Tillikainen L, Pyykkonen J, et al: Testing of the analytical anisotropic algorithm for photon dose calculation. Medical Physics Med Phys 33(11):4130-4148 (2006)
- Breitman K, Rathee S, Newcomb C, et al: Experimental Validation of the Eclipse AAA Algorithm. J Appl Clin Med Phys 8(2):76-92 (2007)
- Fogliata A, Vanetti E, Albers D, et al: On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations. Phys Med Biol 52(5):1363-1385 (2007) https://doi.org/10.1088/0031-9155/52/5/011
- Han T, Mourtada F, Kisling K, et al: Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom. Med Phys 39(4):2193-2202 (2012) https://doi.org/10.1118/1.3692180
- Teh B, Mai WY, Uhl BM, et al: Intensity-modulated radiation therapy for prostate cancer with the use of a rectal balloon for prostate immobilization: acute toxicity and dose-volume analysis. Int J Radiat Oncol Biol Phys 49(3):705-712 (2001) https://doi.org/10.1016/S0360-3016(00)01428-0
- Kim JS, Chung JB, Kim IA, Eom KY: Dosimetric effects of endorectal balloons on intensity-modulated radation therapy plans for prostate cancer. J Korean Phys Soc 63(8):1637-1643 (2013) https://doi.org/10.3938/jkps.63.1637
- Stanley J, Breitman K, Dunscombe P, Spencer D, Lau H: Evaluation of stereotactic radiosurgery conformity indices for 170 target volumes in patients with brain metastases. J Appl Clin Med Phys 12(2):245-253 (2011)
- Yoon M, Park SY, Shin D, et al: A new homogeneity index based on statistical analysis of the dose-volume histogram. J Appl Clin Med Phys 8(2):9-17(2007)
- Hinnen KA, Monninkhof EM, Battermann JJ, et al: Prostate specific antigen bounce is related to overall survival in prostate brachytherapy. Int J Radiat Oncol Biol Phys 82(2):883 (2012) https://doi.org/10.1016/j.ijrobp.2010.11.049
- Leung L, Kan M, Cheng A, et al: A new dose-volume-based plan quality index for IMRT plan comparion. Radiother Oncol 85(3):407-417 (2007) https://doi.org/10.1016/j.radonc.2007.10.018
- Scorsetti M, Alongi F, Castiglioni S, et al: Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments. Radiation Oncology 6:113 (2011) https://doi.org/10.1186/1748-717X-6-113
- Purdie TG, Bissonnette JP. Franks K, et al: Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68(1):243-252 (2007) https://doi.org/10.1016/j.ijrobp.2006.12.022
- Hoogeman MS, Nuyttens JJ, Levendag PC, Heijmen BJ: Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging. Int J Radiat Oncol Biol Phys 70(2):609-0618 (2008) https://doi.org/10.1016/j.ijrobp.2007.08.066
- Vassiliev ON, Kry SF, Chang JY, et al: Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac. J Appl Clin Med Phys 10(1):14-21 (2009)
- Mancosu P, Castiglioni S, Reggiori G, et al: Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations. Radiation Oncology 7:16 (2012) https://doi.org/10.1186/1748-717X-7-16
- Fogliata A, Nicolini G, Clivio A, et al: Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc((R)) stereotactic treatments. Med Phys 38(11):6228-6237 (2011) https://doi.org/10.1118/1.3654739
- Narabayashi M, Mizowaki T, Matsuo Y, et al: Dosimetric evaluation of the impacts of different heterogeneity correction algorithms on target doses in stereotactic body radiation therapy for lung tumors. J Radiat Research 53(5):777-784 (2012) https://doi.org/10.1093/jrr/rrs026
피인용 문헌
- Comparison of VMAT‐SABR treatment plans with flattening filter (FF) and flattening filter‐free (FFF) beam for localized prostate cancer vol.16, pp.6, 2014, https://doi.org/10.1120/jacmp.v16i6.5728
- Dosimetric comparison of a 6-MV flattening-filter and a flattening-filter-free beam for lung stereotactic ablative radiotherapy treatment vol.67, pp.9, 2014, https://doi.org/10.3938/jkps.67.1672
- Dosimetric accuracy of AAA and acuros XB dose calculations within an air cavity for small fields of a 6-MV flattening filter-free beam vol.67, pp.12, 2015, https://doi.org/10.3938/jkps.67.2138
- Comparison of Dosimetric Performance among Commercial Quality Assurance Systems for Verifying Pretreatment Plans of Stereotactic Body Radiotherapy Using Flattening-Filter-Free Beams vol.31, pp.11, 2014, https://doi.org/10.3346/jkms.2016.31.11.1742