Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling

분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상

  • Park, Joo-Saeng (Department of Forest Products, Korea Forest Research Institute) ;
  • Kim, Se-Jong (Department of Forest Products, Korea Forest Research Institute) ;
  • Lee, Sang-Joon (Department of Forest Products, Korea Forest Research Institute)
  • 박주생 (국립산림과학원 재료공학과) ;
  • 김세종 (국립산림과학원 재료공학과) ;
  • 이상준 (국립산림과학원 재료공학과)
  • Received : 2013.09.27
  • Accepted : 2013.10.17
  • Published : 2013.10.25

Abstract

Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

Keywords