DOI QR코드

DOI QR Code

A New Topology of Multilevel Voltage Source Inverter to Minimize the Number of Circuit Devices and Maximize the Number of Output Voltage Levels

  • Received : 2013.01.02
  • Accepted : 2013.05.27
  • Published : 2013.11.01

Abstract

Nowadays multilevel inverters are developing generally due to reduced voltage stress on power switches and low total harmonic distortion (THD) in output voltage. However, for increasing the output voltage levels the number of circuit devices are increased and it results in increasing the cost of converter. In this paper, a novel multilevel inverter is proposed. The suggested topology uses less number of power switches and related gate drive circuits to generate the same level in output voltage with comparison to traditional cascaded multilevel inverter. With the proposed topology all levels in output voltage can be realized. As an illustration, a symmetric 13-level and asymmetric 29-level proposed inverters have been simulated and implemented. The total peak inverse (PIV) and power losses of presented inverter are calculated and compared with conventional cascaded multilevel inverter. The presented analyses show that the power losses in the suggested multilevel inverter are less than the traditional inverters. Presented simulation and experimental results demonstrate the feasibility and applicability of the proposed inverter to obtain the maximum number of levels with less number of switches.

Keywords

1. Introduction

Multilevel inverters have been attracting growing interest since introduced at early 80s [1], particularly because of the higher power rating and quality, higher efficiency, lower total harmonic distortion and lower switching losses [2] & [3]. The mentioned advantages are achieved while the multiple dc sources are used to generate the output voltage waveform [4]. In recent years, MULTILEVEL inverters are one of the most versatile and powerful components that are utilized in many industrials such as FACTS devices [5] & [6], HVDC [7] & [8], etc. Various topologies for multilevel inverters have been introduced over the past 20 years, the most popular topologies are the diode-clamped [9], flying capacitor [10] and cascaded H-bridge topologies [11]. Also, many modulation techniques such as different pulse width modulation (PWM) techniques and space-vector PWM schemes are proposed to improve the output voltage harmonic spectrum [12] & [13]. To synthesize multilevel output, voltage clamping is one of the most important concerns. The definition of clamping is to limit the switch’s terminal voltage in a proper range by using clamping devices. In the three mentioned multilevel-inverter structures, voltages are clamped by diodes, by capacitors and by separated voltage sources in the diode-clamped, the flying capacitor and the cascaded multilevel structures, respectively [14]. One property that distinguishes the cascaded H-bridge from the other multilevel structures is the capability of utilizing various dc voltages on the separate H-bridge cells. This property causes to split the power conversion amongst higher-voltage lower-frequency and lower-voltage higher-frequency inverters [15]. Increasing the number of DC voltage sources causes to increase the number of levels in output voltage waveform and thereby the inverter voltage output waveform reaches a nearly sinusoidal waveform while operating at a fundamental frequency switching scheme [16]. Also to provide a large number of output levels instead of increasing the number of DC sources, asymmetric topologies of multilevel inverters can be used [17] & [18]. Unfortunately, multilevel inverters have some drawbacks. One of their disadvantages is the great number of required components especially power switches and gate drivers. This increases the cost, complexity and size of inverter [3]. It is a good idea to suggest new multilevel-inverter topologies with higher performance by reducing the number of required components [19]. In new multi-level inverter topologies with reduction of switches total PIV will increase, e.g. semi cascaded inverter uses almost half number of switches compared with cascaded converter, but this reduction results that the PIV values is as much as 1.5 times in semi-cascaded converter compared with cascaded converter [20]. This paper proposes a novel topology based on connected several independent units. Compared to traditional cascaded inverter, the proposed topology reduces the number of switches while uses the same number of DC sources with the same values. A new developed topology associated with a suitable method to specify the value of dc voltage sources for symmetrical and asymmetrical multilevel inverter are proposed in this paper. The rest of this paper is organized as follows: In Section II the proposed topology is detailed and the different methods are defined to utilize both symmetric and asymmetric proposed inverter. Section III provides a brief review on traditional cascade multilevel inverter and compares with proposed topology. Simulation and experimental results are given in sections IV and sections V, respectively. Presented results show the feasibility and good performance of proposed topologies and also confirm the author’s accuracy.

 

2. Proposed Topology

The proposed topology includes several independent units which have been combined properly. Each unit consists of two DC sources with the same value and six switches and related gate drives. Fig. 1 shows the topology of basic unit and the related switching scheme for each unit is given as below.

Fig.1.The overall view of basic unit

Table 1.The switching principle of unit i

Fig. 2 shows the topology of proposed multilevel inverter.

The proposed topology consists of 2n-DC voltage sources with 6n-switches which is able to generate zero or positive and negative polarity voltage in all levels. As shown in Fig. 2, each switch consists of an IGBT with antiparallel diode. Both switches(Hi, ), (S1i, ) and (S2i, ) are complementary turned on the whole operation cycle.

It’s noted that, as mentioned in Fig. 2 the proposed topology employs n- basic units which makes it suitable to be used in photovoltaic systems. In photovoltaic system each cell has the DC voltage value which may differs from other cells. To generate all possible levels with equal output voltage steps, the voltage of cells must be same or a DC-DC chopper should be used in output of cells. In proposed inverter to generate all possible levels with equal steps in output voltage; generally two voltage sources in each unit have the same value while the values of DC sources of each unit can be different from another unit. Different values in DC voltages of a unit in proposed inverter effects on the THD value of output voltage.

Fig. 2.The overall view of proposed inverter

The output phase voltage is clamped by DC voltage sources. The maximum output voltage (Vo max)of proposed topology is defined by:

Where 2n is the number of DC voltage sources. The maximum number of output levels in phase voltage (m) is evaluated by:

The conduction and switching losses are two major factors of power losses in a semiconductor switch. In the suggested topology 3n-switches are turned on in different operation modes of inverter. If the on-state voltage drop of a switch points as Vd, the maximum output voltage is illustrated:

And the total peak inverse voltage (PIV) of proposed converter can be obtained as follows:

To obtain a large number of output levels, the proposed topology can be used as an asymmetric multilevel inverter, instead of increasing the number of DC- voltage sources.

For both symmetric and asymmetric operation, the mentioned Eqs. (1-3) and (4) are true. In the following, two various methods are introduced for determination of amplitude of DC voltage sources which are synthesized in the proposed topology are available. It is noticeable that in all suggested methods, each number of output voltage levels can be generated.

2.1 First method

Fig. 3 shows the symmetric topology of 13-level proposed inverter.

If the value of all DC voltage sources Vi in Fig. 3 equal to Vdc, the inverter is known as symmetric topology. The number of output voltage levels of the inverter with 2n-DC voltage sources with same values can be calculated as follows:

Also the maximum output voltage can be evaluated by:

Fig. 3.The symmetric topology of 13-level proposed inverter (V1= V2= V3)

2.2 Second method

In the proposed topology Vi can set to be Vi = Pi−1 * V1, Where p=2, 3… 2n+1. In other words p can be set to adjust the output voltage level to a desired value instead of manipulating the inverter circuit. In this case the proposed multilevel inverter is known as asymmetric topology, which increases the number of the output voltage levels without adding any DC voltage sources and switches. With notice to, Vi = Pi−1 * V1 the all levels can be produced in output voltage and the value of steps will be V1. In the proposed inverter with 2n-DC voltage and assumption Vi = Pi−1 * V1, the maximum output voltage (Vo max) and the number of output voltage levels (m) can be evaluated by (7) and (8), respectively. Table 2 compares the required power devices of proposed multilevel inverter in both methods.

Table 2.Required components of proposed multilevel inverters

 

3. Conventional Cascade Multilevel Inverters Configuration

Fig.4 shows a single-phase cascaded multilevel inverter with separated DC voltage sources.

The output voltage of cascaded multilevel inverter is synthesized by summing the output voltages of bridges. Each H-bridge generates a three-level square-wave voltage associated with four switches an d one DC voltage source. In a cascaded inverter with 2n DC voltage sources with n different values (a set of single phase cascaded inverter shown in Fig. 4) the maximum output voltage (Vo max) and the maximum number of output levels (m) can be obtained from (1) and (2), respectively. It’s evident that in a cascade multilevel inverter with 2n-DC sources, always 4n switches must be turn on in various operation modes, so the maximum output voltage can be defined as:

Where Vd is the on-state voltage drop of a switch.

Fig. 4.single-phase cascaded multilevel inverter

To attain a large number of output levels, the asymmetrical DC sources can be employed in cascaded multilevel inverter instead of increasing the number of Hbridges.

For asymmetric cascaded multilevel inverter with 2n DC sources and n-different values, the mentioned equations (1), (2) are true. The total peak inverse voltage (PIV) of switches for both symmetric and asymmetric can be evaluated in (10) and (11), respectively:

The major sufficiency of cascaded topology is the modularity of control and protection requirements of each H-bridge, but the higher amount of required switches is the major it’s disadvantage. In the proposed topology the number of circuit devices is substantially reduced. For the purpose of comparison, the suggested methods for the proposed topology described in section II are employed for conventional cascaded multilevel inverter. As illustrated before, the proposed inverter and the cascaded inverter need 2n-DC sources with n-different values. Table 3 compares the required power components of the conventional cascaded inverter for both illustrated methods in section 2.

Table 3.Required power components for conventional cascaded inverter

 

4. Comparison Study

The main goal of this paper is to present a new topology which the amount of the required components is lower than the conventional cascaded multilevel inverters.

The number of required switches and also the ratings of them are the great importance in multilevel inverter structures. It’s apparent that the number of switches in proposed topology is noticeably lower than the conventional cascaded inverter in a same output level for both methods, as illustrated in Table 2 and Table 3. Also, voltage and current ratings of the power switches play important roles on the overall cost of the system and realization of the inverter. It can be seen from Table 2 and Table 3 that the total PIV of proposed inverter is lower than the traditional cascaded multilevel inverter with same number of DC voltage sources. Also the number of on-state switches is lower in the proposed topology compared to conventional cascade and so the output voltage drop is reduced. Figs. 5 and 6 represent the results of comparing the conventional cascaded multilevel inverters and the proposed topology from different points of view. Fig. 5 shows the number of switches (IGBTs and gate drivers) versus the number of output voltage levels for symmetric mode of proposed topology and the conventional cascade inverter.

As seen in Fig. 5 the proposed topology requires less number of switches and gate driver circuits for realizing the output voltage levels. Therefore, this achievement reduces the installation area and cost of the proposed topology in comparison with the conventional cascaded inverter for realizing the same output voltage levels.

Fig. 5.The number of switches for symmetric mode of proposed topology and the conventional cascade inverter

The number of on state switches results in output voltage drop and conduction losses of converter. Therefore, it is considered as a substantial factor to compare the conventional cascaded inverter and proposed topology. As presented in Fig. 6 the number of on-state switches for proposed topology is less.

Fig. 6.The number of on-state switches versus output levels

 

5. Calculation of Power Losses

Refers to the given descriptions, the conduction and switching losses are commonly two kinds of losses that is studied in inverters. Conduction losses are due to the equivalent resistance and the on-state voltage drop of the switches. The switching losses are because of non-ideal operation of switches. The below paragraph is arranged to evaluate the losses of the proposed multilevel inverter. So as to calculating the conduction losses, firstly formulas for conduction losses of a typical power semiconductor switch is provided then they are extended to the overall proposed inverter. Each power semiconductor switch includes an IGBT and anti-parallel diode. In the following expression (12) and (13) the instantaneous conduction losses of IGBT and diode are separately formulated [21]. Pc.T(t) is for IGBT and Pc.D(t) is for diode.

VT and VD, are noted the on-state voltage of IGBT and diode respectively and β is a constant dependent to the IGBT characteristic. RT and RD indicate the equivalent resistance of the IGBT and diode, respectively. In the proposed inverter, the number of IGBT, NT(t), and diodes,ND(t), in the current path are varying with time. Because, the number of on state switches is dependent to the output voltage level and operating conditions (essentially direction of the current). In order to calculate the average of conduction power loss the equation (12) and (13) are used and a formula for conduction power loss is provided as follows:

The switching losses are formulated for a typical power semiconductor switch and then obtained formulas are developed to the overall inverter system. To evaluate switching losses, the linear approximation of the current and voltage during switching period is considered. With the assumed approximation, a formula for energy loss during the turn on period of a power semiconductor switch is provided as follows:

Where, Eon,J is the turn on loss of the Jth switch, ton is the turn on time of the mentioned switch and I is the current through the switch after turning on. To formulate the energy loss during the turn off period is only required to substitute the “on” subtitle with “of” in the last term of (15) and I with I', which I' is the current through the switch after turning off.

The switching losses are relevant with the number of switching transitions and also to the control scheme. Commonly, the average switching power loss can be evaluated with the following expression:

Where, f is the fundamental frequency, Non,J and Noff,J are the number of turning on and off the Jth switch during a half fundamental cycle. Also, Eon,Ji , is the energy loss of the Jth switch during the ith turning-on and Eoff,Ji , is the energy loss of the Jth switch during the ith turning-off. Using (14) and (17), the total losses of the overall proposed multilevel inverter is given as follows:

To validate that there is a loss reduction in the proposed multi-level inverter compared with cascaded inverter, loss amount of basic units of proposed inverter and cascade inverter, shown in Fig. 7(a) and (b), are calculated for different modulation indexes and is shown in Fig. 7(c). Both cascaded inverter and proposed inverter are simulated using BUP400D switches with the given real data in [22] and 10v DC voltage sources values and load parameters of 30ohm and 20mH.

Fig. 7.(a) Basic units of proposed inverter; (b) cascaded inverter; (c) Loss comparison for proposed inverter and cascaded inverter

As a case study for the basic unit of proposed inverter and the given data in Table 6 for modulation index equal to 0.2 the demand power is 180W and the supply power of DC sources is 192W which defines that the power loss of proposed inverter is less than 7%.

 

6. Simulation Results

To validate the good performance of the proposed multilevel inverter, a single phase 13-level proposed topology is considered, and the simulation and experimental results are obtained. The MATLAB/Simulink software has been used for simulation. The prototype of proposed topology which includes 6-DC sources and 18 switches generating staircase waveform with the maximum 84 V in output is considered. A series R−L with R=30 ohm and L=20 mH are used as a load. To extend the ability of proposed topologies as an asymmetric inverter, the asymmetrical DC sources are chosen to generate the 84v with the 29 steps in output voltage. Table 4 defines the switching principle of symmetric 13-level proposed inverter.

Table 4.Switching states 13-level proposed symmetric inverter

Fig. 8.(a) The voltage and current waveform (b) the harmonic spectra, of proposed symmetric 13-level inverter

 

7. Experimental Results

To validate the proposed multilevel inverter topology, a 13-level symmetric proposed inverter as shown in Fig. 3 is implemented. Fig. 10 shows the implemented prototype proposed inverter. The control system of proposed inverter is implemented by DSPIC30F4011 controller. To implement the proposed symmetric 9-level inverter 4 dc voltage sources and 12 IGBTs are used. Table 6 represents the implemented circuit parameters. The experimental output voltage in the no load case are shown in Fig. 11 (a). Fig. 11 (b) shows output voltage and current under load condition. Fig. 11 validates the practicability of proposed multilevel which can generate all voltage steps for a test case 13-level symmetric inverter.

Fig. 9.(a) The voltage and current waveform; (b) harmonic spectra, of proposed asymmetric 29-level inverter

Fig. 10.The implemented prototype of proposed 13-level symmetric inverter

Table 6.Value of parameters in implemented inverter

Fig. 11.(a) The voltage waveform; (b) the voltage and current waveform of 13-level proposed symmetric inverter

Fig. 12 validates the practicability of proposed multilevel which can generate all voltage steps for a test case 29-level asymmetric inverter with p=2 and V1=40, V2=80, V3=160.

The obtained experimental results validate the practicability of proposed symmetric and asymmetric multilevel inverters which can generate all voltage steps for a test case 13-level symmetric and 29-level asymmetric inverter.

Fig. 12.(a) The voltage waveform; (b) the voltage and current waveform of a 29-level proposed symmetric inverter

 

8. Conclusion

A new multilevel inverter with a reduced number of power components has been suggested to increase the number of output voltage levels. With the suggested inverter the same level in output voltage is generated with fewer numbers of switches and related gate drive circuits compared to traditional cascaded inverter. Also the number of on-state switches is lower in the proposed topology compared to conventional cascade, so the output voltage drop is reduced and conduction power loss is decreased.

The simulation and experimental results are provided to submit the good performance and applicability of proposed inverter.

References

  1. Pablo Lezana, Roberto Aceiton, "Hybrid Multi-cell Converter: Topology and Modulation", IEEE Transactions on Industrial Electronics, vol. 58, no. 9, Sep. 2011.
  2. Ebrahim Babaei, "A Cascade Multilevel Converter Topology With Reduced Number of Switches," IEEE Transactions on Power Electronics, vol. 23, no. 6, Nov. 2008.
  3. M.R. Banaei, E. Salary, "New multilevel inverter with reduction of switches and gate driver," Energy Conversion and Management, vol. 52, pp. 1129-1136, 2011. https://doi.org/10.1016/j.enconman.2010.09.007
  4. M. Calais, V.G. Agelidis, M. Meinhardt, "Multilevel converters for single phase grid connected photovoltaic systems: an overview," Elsevier J. Solar Energy, vol. 66, no. 6, pp. 325-335, 1999. https://doi.org/10.1016/S0038-092X(99)00035-3
  5. Q. Song and W. Liu, "Control of a cascade STATCOM with star configuration under unbalanced conditions," IEEE Trans. Power Electron., vol. 24, no. 1, pp.45-58, Jan. 2009. https://doi.org/10.1109/TPEL.2008.2009172
  6. B. Geethalakshmi and P. Dananjayan, "Investigation of performance of UPFC without DC link capacitor," Elect. Power Energy Res., vol. 48, no. 4, pp. 736-746, 2008.
  7. Hui Ding, Yi Zhang, Aniruddha M. Gole, Dennis A. Min Xiao Han and Xiang Ning Xiao, "Analysis of Coupling Effects on Overhead VSC-HVDC Transmission Lines From AC Lines With Shared Right of Way," IEEE Transactions on Power Delivery, vol. 25, no. 4, Oct. 2010.
  8. Shuhui Li Timothy A. Haskew and Ling Xu, "Control of HVDC Light System Using Conventional and Direct Current Vector Control Approaches," IEEE Transactions on Power Electronics, vol. 25, no. 12, Dec. 2010.
  9. Changliang Xia, Xin Gu, Tingna Shi, and Yan Yan, "Neutral-Point Potential Balancing of Three-Level Inverters in Direct-Driven Wind Energy Conversion System," IEEE Transactions on Energy Conversion, vol. 26, no. 1, Mar. 2011.
  10. J. Rodriguez, L. G. Franquelo, S. Kouro, J. I. Leon, R. C. Portillo, M. A. M. Prats, M. A. Perez, "Multilevel inverters: an enabling technology for high-power applications," Proceedings of IEEE, vol. 97, no. 11, pp. 1786-1817, Nov. 2009. https://doi.org/10.1109/JPROC.2009.2030235
  11. F.Z. Peng, J.-S. Lai, J.W. McKeever, and J. Van Coevering, "A multilevel voltage-source inverter with separate DC sources for static var generation," IEEE Trans. Ind. Appl., vol. 32, no. 5, pp. 1130-1138, Sep./Oct. 1996. https://doi.org/10.1109/28.536875
  12. Sergio Busquets-Monge, Salvador Alepuz, Joan Rocabert and Josep Bordonau, "Pulse width Modulations for the Comprehensive Capacitor Voltage Balance of n-Level Three-Leg Diode-Clamped Converters," IEEE Transactions on Power Electronics, vol. 24, no. 5, May 2009.
  13. Maryam Saeedifard, Reza Iravani, and Josep Pou, "A Space Vector Modulation Strategy for a Back-to-Back Five-Level HVDC Converter System," IEEE Transactions on Industrial Electronics, vol. 56, no. 2, Feb. 2009.
  14. Alian Chen and Xiangning He, "Research on Hybrid-Clamped Multilevel-Inverter Topologies," IEEE Transactions on Industrial Electronics, vol. 53, no. 6, Dec. 2006.
  15. Keith A. Corzine, Mike W. Wielebski, Fang Z. Peng and Jin Wang, "Control of Cascaded Multilevel Inverters," IEEE Transactions on Power Electronics, vol. 19, no. 3, May 2004.
  16. Sung Geun Song, Feel Soon Kang and Sung-Jun Park, "Cascaded Multilevel Inverter Employing Three-Phase Transformers and Single DC Input," IEEE Transactions on Industrial Electronics, vol. 56, no. 6, Jun. 2009.
  17. Ebrahim Babaei, Mohammad Sadegh Moeinian, "Asymmetric cascaded multilevel inverter with charge balance control of a low resolution symmetric subsystem," Energy Conversion and Management, vol. 51, pp. 2272-2278, 2010. https://doi.org/10.1016/j.enconman.2010.03.022
  18. Veenstra M, Rufer A. "Control of a hybrid asymmetric multilevel inverter for competitive medium-voltage industrial drives," IEEE Transactions on Industrial Applications, vol. 41, no. 2, pp. 655-664, 2005. https://doi.org/10.1109/TIA.2005.844382
  19. Lezana P, Rodriguez J. "Mixed multi-cell cascaded multilevel inverter," ISIE 2007 IEEE international symposium, June, 2007.
  20. Ebrahim Babaei, Seyed Hossein Hosseini, New cascaded multilevel inverter topology with minimum number of switches, Energy Conversion and Management, vol. 50, pp. 2761-2767, 2009. https://doi.org/10.1016/j.enconman.2009.06.032
  21. Kangarlu, M.F., Babaei, E, "A generalized cascaded multilevel inverter using series connection of submultilevel inverters ," IEEE Trans. Power Electronics, vol. 28, no. 2, pp. 625-636, Feb 2013. https://doi.org/10.1109/TPEL.2012.2203339
  22. Data sheet of IGBT 'BUP 400D', Available at: www.datasheetcatalog.com .

Cited by

  1. An Innovative Scheme of Symmetric Multilevel Voltage Source Inverter With Lower Number of Circuit Devices vol.62, pp.11, 2015, https://doi.org/10.1109/TIE.2015.2438059
  2. Comparison of Reduced Part Count Multilevel Inverters (RPC-MLIs) for Grid Interfacing 2017, https://doi.org/10.1080/03772063.2017.1367262
  3. A novel symmetric/asymmetric multilevel current source inverter topology with lower number of components and lowest power rating of switches vol.38, pp.8, 2017, https://doi.org/10.1080/01430750.2016.1222957
  4. Selective Harmonic Elimination of Cascaded Multilevel Inverter Using BAT Algorithm vol.21, 2015, https://doi.org/10.1016/j.protcy.2015.10.078
  5. Reduction of Components in New Family of Diode Clamp Multilevel Inverter Ordeal to Induction Motor vol.16, pp.1, 2016, https://doi.org/10.5573/JSTS.2016.16.1.058
  6. Hybrid Control Strategy for BCD Topology Based Modular Multilevel Inverter vol.07, pp.08, 2016, https://doi.org/10.4236/cs.2016.78126
  7. A new topology for cascaded H-bridge multilevel inverter with PI and Fuzzy control vol.117, 2017, https://doi.org/10.1016/j.egypro.2017.05.211
  8. Simulation and Analysis of Novel Extendable Multilevel Inverter Topology pp.1793-6454, 2018, https://doi.org/10.1142/S0218126619500890
  9. An Improved Symmetric H-Bridge Multilevel Converter Topology; An Attempt to Reduce Power Losses vol.27, pp.12, 2018, https://doi.org/10.1142/S0218126618501876