Acknowledgement
Supported by : National Research Foundation
References
- Al-Mayah, A., Soudki, K. and Plumtree, A. (2013), "Towards a simplified anchor system for CFRP rods", Journal of Composites for Construction. (in press)
- ASTM International (2012), "Standard Specification for Steel Strand, Uncoated Seven-Wire for Prestressed Concrete", ASTM A416, USA
- EOTA (2002), "Guideline for European Technical Approval of Post-Tensioning Kits for Prestressing of Structures (ETAG 013)", EOTA, Brussels.
- Fib (2005), "Acceptance of stay cable systems using prestressing steels", International Federation for Structural Concrete fib, Lausanne, Switzerland.
- Godfrey, H.J. (1956), "The physical properties and methods of testing prestressed concrete wire strand", PCI Journal, 1(3), 38-47.
- Hill, A.T. Jr. (2006), "Material properties of grade 300 and grade 270 prestressing strands and their impact on the design of bridges", M.S. Thesis, Virginia Polytechnic Institute and State University, Blacksburg,VA.
- ISO 15630-3 (2010), "Steel for the reinforcement and prestressing of concrete - Test methods - Part 3:prestressing steel", The International Organization for Standardization, Switzerland.
- Kim, J.K., Lee, P.G. and Lee, M.S. (2010), "Development of 2,160MPa strand and application technology",Magazine of Korea Concrete Institute, 25(1), 68-70. (in Korean)
- KS D 7002 (2011), "Uncoated stress-relieved steel wires and strands for prestressed concrete", Korean Standards Association, Seoul, Korea.
- KS D 3752 (2007), "Carbon steel for machine structural use", Korean Standards Association, Seoul, Korea.
- KS D 3867 (2007), "Low-alloy steels for machine structural use", Korean Standards Association, Seoul, Korea.
- Kwon, S.H. and Shah, S.P. (2008), "Prediction of early-age cracking of fiber-reinforced concrete due to restrained shrinkage", ACI Materials Journal, 105(4), 381-389.
- Kwon, S.H., Ferron, R.P., Akkaya, Y. and Shah, S.P. (2007), "Cracking of fiber-reinforced self-compacting concrete due to restrained shrinkage", International Journal of Concrete Structures and Materials, 1(1), 3-9. https://doi.org/10.4334/IJCSM.2007.1.1.003
- Loflin, B.J. (2008), "Bond and material properties of grade 270 and grade 300 prestressing strands", Master Degree Thesis at Virginia Polytechnic Institute and State University, Virginia, USA.
- Noh, M.H., Seong, T.R. and Kim, J.K. (2012), "Nonlinear analysis of anchor head for high strength steel strand", COSEIK Journal, 25(2), 163-174. https://doi.org/10.7734/COSEIK.2012.25.2.163
- Paik, I.Y., Shim C.S., Chung, Y.S. and Sang, H.J. (2011), "Statistical properties of material strength of concrete, re-bar and strand used in domestic construction site", Journal of the Korea Concrete Institute,23(4), 421-430. (in Korean) https://doi.org/10.4334/JKCI.2011.23.4.421
- Preston, H.K. (1985), "Testing 7-wire strand for prestressed concrete-the state of the art", PCI Journal, 30(3), 134-155. https://doi.org/10.15554/pcij.05011985.134.155
- Preston, H.K. (1990), "Handling prestressed concrete strand", PCI Journal, 35(6), 68-71. https://doi.org/10.15554/pcij.11011990.68.71
- PTI (1998), "Acceptance Standards for Post-Tensioning Systems", Post-Tensioning Institute, Phoenix, USA.
- PTI (2012), "Recommendations for Stay Cable Design, Testing, and Installation", Post-Tensioning Institute, Phoenix, USA.
- Seo, J.W., Jeong, W. and You, H. (2010), "Socket design and safety review on PPWS cable for suspension bridge", 2010 KSCE Conference Proceedings, 2517-2517. (in Korean)
- Seo, J.W., Jeong, W., Cho, E.K. and You, H. (2010), "Parametric analysis to determine optimum geometries of PPWS sockets in cable-suspension bridges", 2010 KSCE Conference Proceedings, 35-36. (in Korean)
- Setra (2009), "European Technical Approval No ETA-09/0068", Setra, Bagneux Cedex, France.
- Setra (2006), "European Technical Approval No ETA-06/0006", Setra, Bagneux Cedex, France.
- Terrasi, G.P., Affolter, C. and Barbezat, M. (2011), "Numerical optimization of a compact and reusable pretensioning anchorage system for CFRP tendons", Journal of composites for construction, 15(2), 126 -135. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000080
- Walsh, K.Q. and Kurama, Y.C. (2012), "Effects of loading conditions on the behavior of unbonded posttensioning strand-anchorage systems", PCI Journal, 76-86.
- Walsh, K.Q. (2009), "Behavior and design of unbonded post-tensioning strand/anchorage systems for seismic applications", Master Degree Thesis at University of Notre Dame, Indiana, USA.
- Wang, X.H. and Liu, X.L. (2012), "Analysis of RC beam with unbonded or exposed tensile reinforcements and defective stirrup anchorages for shear strength", Computers and Concrete, 10(1), 59-78. https://doi.org/10.12989/cac.2012.10.1.059
Cited by
- Ductility Analysis of Prestressed Concrete Members with High-Strength Strands and Code Implications vol.114, pp.2, 2017, https://doi.org/10.14359/51689435
- Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high-strength pretensioned prestressed concrete beam vol.17, pp.4, 2016, https://doi.org/10.12989/sss.2016.17.4.577
- Experimental Evaluation of Transfer Length in Pretensioned Concrete Beams Using 2,400-MPa Prestressed Strands vol.142, pp.11, 2016, https://doi.org/10.1061/(ASCE)ST.1943-541X.0001567
- Influence of steel fiber and reinforcing details on the ultimate bearing strength of the post-tensioning anchorage zone vol.59, pp.5, 2016, https://doi.org/10.12989/sem.2016.59.5.867
- Transfer length in full-scale pretensioned concrete beams with 1.4 m and 2.4 m section depths vol.171, pp.None, 2018, https://doi.org/10.1016/j.engstruct.2018.05.104
- Effect of design variables on deflected tensile performance of high-strength 7-wire steel strand for stay cable vol.188, pp.None, 2018, https://doi.org/10.1016/j.conbuildmat.2018.08.106
- Development and application of a hybrid prestressed segmental concrete girder utilizing low carbon materials vol.69, pp.4, 2013, https://doi.org/10.12989/sem.2019.69.4.371
- Testing Methodology for Tensile Strength Evaluation of PSC Strands vol.31, pp.4, 2019, https://doi.org/10.7781/kjoss.2019.31.5.361
- Prediction of Transfer Lengths Inclusive of Conventional and High-Strength Strands vol.146, pp.9, 2013, https://doi.org/10.1061/(asce)st.1943-541x.0002765