Abstract

The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.

Keywords

References

  1. Yool Park, Jong-Il Park, A study of Energy use Impacts by SHGCs of Windows in Detached House, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, pp. 189-196
  2. Joshua Apte, Dariush Arasteh, Yu Joe Huang, 2003, Future Advanced Windows for Zero-Energy Homes, ASHRAE Transactions, Vol.109, Part 2, pp.871-882
  3. Dariush Arasteh, Howdy Goudey, Joe huang, Christian Kohler, and Robin Mitchell, 2006, Performance Criteria for Residential Zero Energy Windows, ASHRAE Transactions, Vol.103, Part 1, pp. 176-185
  4. Shin, J. G., Kim, K. J., Jeong, J. W., Choi, W. K., 2011, A Study on the Energy Consumption Patterns according to Correlation of SHGC and U-value in Commercial- Residential Buildings, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 23, pp. 695-698
  5. Yoon, J. H., Hong, W. W., Hwang, W. J., Choi, W. K., A Study of Correlation Between Window Performance and Building Energy, 2011, Vol. 27. No. 12, pp. 341-348
  6. Leigh, S. B., Won, J. S., 2004, An analysis of demand for environmental controls on different residential building types, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, pp. 960-968

Cited by

  1. Heating and Cooling Energy Conservation Effects by Green Roof Systems in Relation with Building Location, Usage and Number of Floors vol.14, pp.2, 2014, https://doi.org/10.12813/kieae.2014.14.2.011
  2. Analysis on Energy Performance of Educational Facility by Composition of Double Glass vol.1119, pp.1662-8985, 2015, https://doi.org/10.4028/www.scientific.net/AMR.1119.756
  3. 창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가 vol.30, pp.4, 2018, https://doi.org/10.6110/kjacr.2018.30.4.159
  4. Daylighting performance enhancement of an apartment building by remodeling vol.19, pp.2, 2019, https://doi.org/10.12813/kieae.2019.19.2.073
  5. Energy Performance Analysis of Photochromic Window in Office Buildings According to Climate Zone vol.20, pp.6, 2013, https://doi.org/10.12813/kieae.2020.20.6.119