DOI QR코드

DOI QR Code

Performance of attachments used in implant-supported overdentures: review of trends in the literature

  • Lee, Damian J. (Department of Restorative Dentistry, University of Illinois at Chicago College of Dentistry)
  • 투고 : 2012.12.18
  • 심사 : 2013.02.03
  • 발행 : 2013.02.28

초록

The purpose of this review is to examine the performance of attachments used in implant-supported overdenture (IOD) in both clinical and in vitro settings and report the compiled findings, comparisons, and trends in the research literature. Articles published in PubMed on IOD attachment systems and performance were reviewed. Non-original articles were excluded. For each article included, the type of study, number of implants, number of attachment systems, and study outcome were recorded. Of the 283 articles found, 158 met the inclusion criteria. Ninety-four articles were clinical studies and 64 articles were in vitro studies. Studies on retention were the most common for in vitro studies, and four or more attachment systems were compared in most articles with significant differences in outcome. A clinical outcome of one attachment system was most common for clinical studies, while most studies had neutral outcomes overall. Ball attachment was the most commonly tested IOD attachment system. The trend in the literature showed that there is a large discrepancy between the study designs and outcomes between the clinical and the in vitro studies for IOD. Further clinical studies that can validate in vitro research should be encouraged to address this discrepancy between the two areas.

키워드

참고문헌

  1. Cehreli MC, Karasoy D, Kokat AM, Akca K, Eckert SE. Systematic review of prosthetic maintenance requirements for implant-supported overdentures. Int J Oral Maxillofac Implants 2010;25:163-80.
  2. Naert I, Alsaadi G, Quirynen M. Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study. Int J Prosthodont 2004;17:401-10.
  3. Fromentin O, Lassauzay C, Abi Nader S, Feine J, de Albuquerque Junior RF. Testing the retention of attachments for implant overdentures: validation of an original force measurement system. J Oral Rehabil 2010;37:54-62. https://doi.org/10.1111/j.1365-2842.2009.02020.x
  4. Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34. https://doi.org/10.1097/01.id.0000202419.21665.36
  5. Fueki K, Kimoto K, Ogawa T, Garrett NR. Effect of implant-supported or retained dentures on masticatory performance: a systematic review. J Prosthet Dent 2007;98: 470-7. https://doi.org/10.1016/S0022-3913(07)60147-4
  6. Klemetti E. Is there a certain number of implants needed to retain an overdenture? J Oral Rehabil 2008;35 Suppl 1:80-4. https://doi.org/10.1111/j.1365-2842.2007.01825.x
  7. Slot W, Raghoebar GM, Vissink A, Huddleston Slater JJ, Meijer HJ. A systematic review of implant-supported maxillary overdentures after a mean observation period of at least 1 year. J Clin Periodontol 2010;37:98-110. https://doi.org/10.1111/j.1600-051X.2009.01493.x
  8. Andreiotelli M, Att W, Strub JR. Prosthodontic complications with implant overdentures: a systematic literature review. Int J Prosthodont 2010;23:195-203.
  9. Jacob RF, Carr AB. Hierarchy of research design used to categorize the "strength of evidence" in answering clinical dental questions. J Prosthet Dent 2000;83:137-52. https://doi.org/10.1053/pr.2000.v83.apr832137
  10. Yuan JC, Shyamsunder N, Barao VA, Lee DJ, Sukotjo C. Publication bias in five dental implant journals: an observation from 2005 to 2009. Int J Oral Maxillofac Implants 2011;26:1024-32.
  11. Hasenboehler EA, Choudhry IK, Newman JT, Smith WR, Ziran BH, Stahel PF. Bias towards publishing positive results in orthopedic and general surgery: a patient safety issue? Patient Saf Surg 2007;1:4. https://doi.org/10.1186/1754-9493-1-4
  12. Verplancke K, De Waele W, De Bruyn H. Dental Implants, what should be known before starting an in vitro study. Sustain Constr Des 2011;2:360-9.
  13. Watters MP, Goodman NW. Comparison of basic methods in clinical studies and in vitro tissue and cell culture studies reported in three anaesthesia journals. Br J Anaesth 1999;82:295-8. https://doi.org/10.1093/bja/82.2.295
  14. Ding X, Liao SH, Zhu XH, Zhang XH, Zhang L. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants. Clin Implant Dent Relat Res 2009;11:279-87. https://doi.org/10.1111/j.1708-8208.2008.00124.x
  15. Alsabeeha N, Payne AG, De Silva RK, Swain MV. Mandibular single-implant overdentures: a review with surgical and prosthodontic perspectives of a novel approach. Clin Oral Implants Res 2009;20:356-65. https://doi.org/10.1111/j.1600-0501.2008.01666.x
  16. Alsabeeha NH, Swain MV, Payne AG. Clinical performance and material properties of single-implant overdenture attachment systems. Int J Prosthodont 2011;24:247-54.
  17. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. Int J Oral Maxillofac Implants 2002;17:601-2.
  18. Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, et al. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients: the York Consensus Statement. Br Dent J 2009;207:185-6. https://doi.org/10.1038/sj.bdj.2009.728
  19. Geckili O, Bilhan H, Mumcu E. Clinical and radiographic evaluation of three-implant-retained mandibular overdentures: a 3-year retrospective study. Quintessence Int 2011;42:721-8.
  20. Liu J, Pan S, Dong J, Mo Z, Fan Y, Feng H. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis. J Dent 2012 Nov 14 [Epub]. http://dx.doi.org/10.1016/j.jdent.2012.11.008.
  21. American Dental Association, Commission on Dental Accreditation. Accreditation standards for advanced specialty education programs in prosthodontics. Chicago: American Dental Association; 2008.
  22. Yuan JC, Kaste LM, Lee DJ, Harlow RF, Knoernschild KL, Campbell SD, et al. Dental student perceptions of predoctoral implant education and plans for providing implant treatment. J Dent Educ 2011;75:750-60.
  23. Lee DJ, Harlow RE, Yuan JC, Sukotjo C, Knoernschild KL, Campbell SD. Three-year clinical outcomes of implant treatments provided at a predoctoral implant program. Int J Prosthodont 2011;24:71-6.
  24. Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J Prosthodont 2012;25:392-4.
  25. Kleis WK, Kammerer PW, Hartmann S, Al-Nawas B, Wagner W. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. Clin Implant Dent Relat Res 2010;12:209-18.

피인용 문헌

  1. Rehabilitation with implant-supported overdentures in total edentulous patients: A review vol.5, pp.5, 2013, https://doi.org/10.4317/jced.50817
  2. Scientific Interests of 21st Century Clinical Oral Implant Research: Topical Trend Analysis vol.18, pp.4, 2013, https://doi.org/10.1111/cid.12371
  3. Retention Force and Wear Characteristics of three Attachment Systems after Dislodging Cycles vol.29, pp.6, 2013, https://doi.org/10.1590/0103-6440201802074
  4. Mandibular implant-supported overdenture: A systematic review and meta-analysis for optimum selection of attachment system vol.21, pp.4, 2013, https://doi.org/10.4103/jips.jips_158_21