DOI QR코드

DOI QR Code

Electro-Catalytic Oxidation of Amoxicillin by Carbon Ceramic Electrode Modified with Copper Iodide

  • Received : 2012.12.24
  • Accepted : 2013.04.15
  • Published : 2013.06.20

Abstract

Copper iodide was employed as a modifier for preparation of a new carbon ceramic electrode. For the first time, the catalytic oxidation of amoxicillin (AMX) was demonstrated by cyclic voltammetry, chronoamperometry and amperometry methods at the surface of this modified carbon ceramic electrode. The copper iodide modified sol-gel derived carbon ceramic (CIM-SGD-CC) electrode has very high catalytic ability for electrooxidation of amoxicillin. The catalytic oxidation peak current was linearly dependent on the amoxicillin concentration and the linearity range obtained was 100 to 1000 ${\mu}mol\;L^{-1}$ with a detection limit of 0.53 ${\mu}mol\;L^{-1}$. The diffusion coefficient ($D=(1.67{\pm}0.102){\times}10^{-3}\;cm^2\;s^{-1}$), and the kinetic parameter such as the electron transfer coefficient (${\alpha}$) and exchange current density ($j_0$) for the modified electrode were calculated. The advantages of the modified CCE are its good stability and reproducibility of surface renewal by simple polishing, excellent catalytic activity and simplicity of preparation.

Keywords

INTRODUCTION

Antibiotics are among the most important compounds used in medicine and have been applied in large quantities for some decades.1 The penicillins are one of the most important groups of antibiotics. Since the first penicillin became available numerous other antimicrobial agents have been produced, but penicillins are still widely used, major antibiotics and they are presently the drugs used for a number of infectious diseases.2 Two commonly used types of antibiotics are sulphonamides and β-actams. Amoxicillin (AMX), (D-α-amino-p-hydroxybenzylpenicillin trihydrate), is the only phenolic penicillin and a moderatespectrum β-lactam antibiotic used in humans and food-producing animals to treat several diseases. β-lactam antibiotics presents a structure based on a β-lactam ring responsible for the antibacterial activity and variable side chains that account for the major differences in their chemical and pharmacological properties.3 AMX is one of the more important antibiotics used in the treatment of bacterial infections and its determination.

Most of the reported methods suffer from disadvantages such as complicated procedure, time consuming, requirement of expensive instruments and low detection sensitivity. Some mentioned analytical problems could be solved using particular electrochemical methods with application of modified electrodes. In recent years many electrodes e.g.(gold, platinum and copper electrode) has been reported,4 and substances e.g (poly-4-vinyl pyridine,5 poly N-vinyl imidazole, 6 [N,N ethylene-bis(salicylideneaminato)] oxovanadium( IV), [VO (Salen)]7 and nickel–curcumin complex8 modified carbon paste electrode, ferrocenedicarboxylic acid multi wall carbon nanotubes paste electrode have been used to make chemically modified electrodes to improve the voltammetric technique. Despite this, development of simple and low cost electrodes is very interest. It is well known that the Cu based chemically modified electrodes (CMEs) have many advantages, such as the operability, commercial availability, not requiring the use of a pulsed potential waveform for stable long term detection and being oxidizable.9 Increasing interest has been focused on sol-gel derived carbon ceramic electrodes (CCEs).

This paper describes fabricated of simple and sensitive new sol-gel derived carbon ceramic electrode modified with copper iodide. In continuation, we employed the modified electrode for electrooxidation of the amoxicillin in NaOH solution and the results were discussed in details.

 

EXPERIMENTAL

Reagents and Solutions

Methyltrimethoxysilane (for synthesis) was purchased from Merck and used without any further purification. Fine powdered graphite (diameter 2–3 μm) was obtained from Merck. Amoxicillin trihydrate (C16H19N3O5·3H2O) was purchased from Sigma. Amoxicillin solutions were prepared every 2 weeks and stored in a refrigerator at 4 oC. All of the reagents used in this work were in analytical grade.

Apparatus

Electrochemical measurements were carried out in a conventional three-electrode cell powered by an electrochemical system comprising an AUTOLAB system with PGSTAT12 boards (ECO Chemie, Utrecht, and The Netherlands). The system was run on a PC using GPES 4.9 software. CIM-SGD-CC electrode as working electrode (prepared as follows) was employed for the electrochemical studies. A platinum wire was employed as counter electrode and an Ag/AgCl electrode served as the reference electrode. All experiments were performed at room temperature of 25±2 oC.

Preparation of CIM-SGD-CC Electrode

The CIM-SGD-CC electrodes were prepared according to the procedure described by the Lev and coworkers.10 At the first stage, 0.3 mL of MTMOS, 0.45 mL of methanol, and 10 μL of hydrochloric acid (11 M) were mixed and stirred for 3 min until a homogeneous gel solution appeared, then 0.3 g of carbon powder and CuI powder at a sufficient ratio (10:90) were added and the resultant mixture shaken for an additional 1 min. The hydrochloric acid acts as catalyst for the hydrolysis of the MTMOS. Then the mixture was added into Teflon tubes (with 2 mm inner diameter and 5 cm length, and the length of composite material in the tube was about 0.5 cm) and dried for at least 24 h at room temperature. Then the electrode was polished with polishing paper and rinsed with distilled water. The same procedure was used for preparation of bare carbon ceramic electrode without copper iodide. The electric contact was made with a copper wire through the back of the electrode. The electrode surface was first carefully polished with polishing paper, rinsed with doubly distilled water, and finally dried by air drying.

 

RESULTS AND DISCUSSION

Electrochemical properties of the prepared CIM-SGDCC electrode were investigated. In this study, for the activation of the electrode surface, the electrode was placed in 0.1 mol L−1 NaOH solution in the potential range of −250 to 1000 mV (vs. Ag/AgCl) at a scan rate of 50 mVs−1 (Fig. 1). There are prominent peaks at approximately −68 and 570 mV during the first cycle but in the second and next cycles, featureless voltammograms were recorded. This indicates that an irreversible electrochemical transformation of the CuI has been achieved during the cyclic voltammetry. Surface elemental analysis of this modified electrode was studied by energy dispersive X-ray (EDX) technique. Fig. 2 illustrates the elemental composition of the electrode surface respectively. Also, EDX analysis of CCE revealed one silica peak at 1.7 keV that it severe overlaps with the gold peak. This peak can be attributed to sol-gel precursor used for electrode preparation. It seems that a film of oxy copper iodide is formed at the surface of electrode during the cyclic voltammetry step, according to the following reaction:11

Figure 1.Repetitive cyclic voltammograms of CIM-SGD-CC electrode in 0.1M NaOH in the potential range of −250-1000 mV. Potential sweep rate is 50 mV s−1. (a) first cycle; (e) end cycle.

Figure 2.Energy disperse X-ray (EDX) on the surface of CIMSGD- CC electrode.

One of the objectives of the present study was to fabricate a modified electrode capable of the electrocatalytic oxidation of amoxicillin. In order to test the electrocatalytic activity of the CIM-SGD-CC electrode, the cyclic voltammograms were obtained in the presence and absence of amoxicillin at bare (Fig. 3a,b) and CIM-SGD-CC (Fig. 3c,d) electrodes. At the bare electrode, no anodic current due to the oxidation of amoxicillin is observed but for CIM-SGD-CC electrode a large anodic peak is observed. It was found that in comparison to unmodified carbon ceramic electrode, electrochemical behavior of amoxicillin was greatly improved at CIM-SGD-CC electrode, indicating that the anodic oxidation of amoxicillin could be catalyzed at CIM-SGD-CC electrode. This proves that the copper iodide bears the main role in electro-catalytic oxidation of amoxicillin. We previously proved that the presence of halides causes an increase activity in the electrocatalytic behavior of copper. The increased activity probably related to a more favorable adsorption of reactant or of intermediates leading to a higher surface concentration of electroactive molecules ready for being oxidized or it is due to the partial delocalization of the electronic density of reactant into the solid with possible consequent bond pre-dissociations which facilitates the oxidation or both.12

Figure 3.Cyclic voltammograms of bare CCE (a,b) and CIMSGD- CC electrode (c,d) in 0.1 mol L−1 NaOH solution in the absence (a,c) and presence of 600 μmol L−1 amoxicillin (b,d). Conditions: potential range −100 to 850 mV scan rate of 50 mV s−1.

Fig. 4 shows the effect of amoxicillin concentration on the cyclic voltammograms of the CIM-SGD-CC electrode. As can be seen from Fig. 4, the height of the anodic peak increases with increasing amoxicillin concentration. The characteristic shape of cyclic voltammogram in this potential region indicates that the signal is due to the oxidation of amoxicillin. The catalytic peak current is proportional to the concentration of amoxicillin in the range of 100 to 1000 μmol L−1. The linear regression equation is I (μA) =1.0137 CAmoxicillin (μmol L−1) − 3.9333 (R=0.9904). The detection limit calculated from the calibration graph was 71 μmol L−1 amoxicillin.

Figure 4.(A) Cyclic voltammograms of a copper iodide modified sol-gel electrode in the presence of various amoxicillin concentrations: (a)−(j): 100, 200, 300, 400, 500, 600, 700, 800, 900, and 1000 μmol L−1, respectively, at a scan rate of 50 mV s−1, in 0.1 mol L−1 NaOH solution. (B) Variation of anodic peak current vs. amoxicillin concentration.

The cyclic voltammograms of CIM-SGD-CC electrode were recorded in different concentrations of NaOH solution containing 400 μmol L−1 amoxicillin (not shown). It is shown that, the high catalytic peak current is achieved above a NaOH concentration of 0.1 mol L−1. So, 0.1 mol L−1 NaOH was chosen as an optimum supporting electrolyte.

In order to test the effects of scan rate on the cyclic voltammograms of CIM-SGD-CC electrode in the presence of 300 μmol L−1 amoxicillin recorded in 0.1 mol L−1 NaOH solution at different scan rates (Fig. 5A). As can be seen, the anodic peaks potential shifted to more positive potentials with increasing of potential scan rate. However the electrocatalytic oxidation current of amoxicillin linearly increased with the square root of potential scan rate (Fig.5A), which demonstrates the reaction is diffusion controlled. Also, plotting the current function against the potential sweep rate (Fig. 5B) revealed negative slope confirming the electrocatalytic nature of the process.

Figure 5.(A) Cyclic voltammograms of CIM-SGD-CC electrode in 0.1 mol L−1 NaOH containing 300 μmol L−1 of amoxicillin at various potential scan rates (from inner to outer) 5−100 mVs−1. (B) Variation of the catalytic current with the square root of sweep rate. (C) Current function vs. v for 0.1 M NaOH solution in the presence of 300 μmol L−1 amoxicillin.

To obtain some information on the rate-determining step, a Tafel plot (Fig. 6) was drawn using the data from the rising part of the current−voltage curves recorded at low scan rate for an amoxicillin concentration of 300 μmol L−1. The Tafel slope for the linear parts of the plot recorded at scan rate of 5 mVs−1 was estimated as being equal to 0.1756 V decade−1, indicating that one-electron process involved in the rate-limiting step, assuming a transfer coefficient (α) of approximately (0.34±0.02). The exchange current density (j0) evaluated from Tafel plots is (0.84±0.22) ×10−6 Acm−2.

Figure 6.Tafel plot derived from the rising part of voltammogram recorded at a scan rate 5 mV s−1.

The Tafel slope was also obtained from the linear relationship observed for Ep versus log ν (not shown) by using the following equation:13

On the basis of Eq. (1) the slope of Ep versus log ν plot is b/2, where b indicates the Tafel slope. The slope of Ep versus log ν plot is ∂Ep/∂ log ν which was found to be 97.939, so b = 195.878, which is in good agreement with the corresponding value evaluated from polarization measurements. This slope indicates that a one electron transfer process is the rate limiting step assuming a transfer coefficient of α = 0.30.

In order to evaluate the reaction kinetics, the oxidation of amoxicillin on CIM-SGD-CC electrode was investigated by chronoamperometry. Chronoamperometry, as well as cyclic voltammetry has been employed for the investigation of the processes occurring via an ErCi mechanism.14 Double steps chronoamperograms were recorded by setting the working electrode potentials to desired values and were used to measure the catalytic rate constant on the modified surface. Fig. 7A shows a series of well-defined chronoamperograms for the CIM-SGD-CC electrode in the absence and presence of different concentrations of amoxicillin at an applied potential of 0.42 V versus Ag/ AgCl. The plot of net current with respect to the mines square roots of time presents a linear dependency (Fig. 7B). This indicates that the transient current must be controlled by a diffusion process. The transient current is due to catalytic oxidation of amoxicillin, which increases as the amoxicillin concentration is raised. No significant cathodic current was observed when the electrolysis potential was stepped to 0.00 mV (vs. Ag/AgCl), indicating the irreversible nature of the oxidation of amoxicillin. By using the slopes of these lines; we can obtain the diffusion coefficients of the significant according to the Cottrell equation: 15

Figure 7.(A) Chronoamperograms of CIM-SGD-CC electrode in 0.1 M NaOH contaning different concentrations of amoxicillin: 0.0, 100, 200, 300, 400 and 500 μmol L−1, from (a) to (g), respectively. Potential steps were 0.42 and 0.0 V, respectively. Insets: Variation of chronoamperometric currents at t = 30 s vs. concentration of amoxicillin. (B) Plot of I vs. t1/2 obtained from chronoamperometric measurements CIM-SGD-CC electrode in 0.1 mol L−1 NaOH contaning different concentrations of amoxicillin: 100, 200, 300, 400 and 600 μmol L−1, from (b) to (f), respectively. (C) The relationship between the slope of the linear segments and the amoxicillin concentration. (D) Dependency of Icatal/Id on t1/2 derived from CAs of (a) and (d) in panel (A).

Where D is the diffusion coefficient, and C* is the bulk concentration. The slopes of the resulting straight lines were then plotted versus the concentration of amoxicillin (Fig. 7C), from which we calculated a diffusion coefficient of (1.67±0.102)×10−3 cm2 s−1 for amoxicillin.

The rate constants of the reactions of amoxicillin and the ensuing intermediates with the redox sites of the CIMSGD- CC electrode can be derived from the chronoamperograms according to Eq. (3):16

where Icatal is the catalytic current in the presence of amoxicillin, Id is the limiting current in the absence of amoxicillin and λ = kCt (k, C and t are the catalytic rate constant, bulk concentration of amoxicillin and the elapsed time, respectively) is the argument of the error function. For λ > 1.5, erf (λ1/2) almost equals unity and Eq. (4) reduces to:17

From the slope of the Icatal/Id vs. t1/2 plot (Fig. 7D), the value of k for 4×10−4 mol L−1 amoxicillin was calculated to be (20.9 ± 0.39)×104 cm3 mol−1 s−1.

Analytical characteristics of CIM-SGD-CC electrode for the amperometric determination of amoxicillin were estimated. Fig. 8 shows the current-time responses of the modified electrode to amoxicillin which was successively added to the electrochemical cell containing 0.1 mol L−1 NaOH under hydrodynamic conditions, while the electrode potential was kept at 0.42. As shown in the figure a well-defined response was observed during the stepwise increasing of amoxicillin concentration in the range 10−65 μmol L−1. It was observed that the sensor responds so rapidly to the substrate, as about 95% of the steady-state current appears within 20 s. The linear regression equation of calibration curve is expressed as I (μA) = 1.8103 CAMX μmol L−1+ 58.747 with a correlation coefficient of 0.9954 (n=12). The limits of detection (LOD) was evaluated by statistical treatment 3 S.D./b, where S.D. is the standard deviation of the blanks in their amperometric responses and b is the slope of the calibration curves. The sensitivity and limit of detection (LOD) were found to be 1.8103 μA/ μmol L−1 and 0.53 μmol L−1, respectively.

Figure 8.The current – time profiles recorded at the CIM-SGDCC electrode during the successive addition of amoxicillin. Inset: Typical calibration graph derived from the current – time profile.

By repetitive CV of the CIM-SGD-CC electrode for approximately 20 times in NaOH solution at a scan rate of 50 mV s−1, the peak current value decreases less than 7%, indicating good stability.

The modified electrode retained its initiate activity for more than 50 days when kept in air at ambient conditions. A decrease of 12% was observed in the current response of the electrode at the end of 50th day. In addition, repetitive recording of cyclic voltamograms in amoxicillin solution tested the reproducibility of the electrocatalytic effect of the modified CCE. It was found that the relative standard deviation (R.S.D.) of the peak currents of 300 μmol L−1 amoxicillin for six replicate determinations was 2.9%. Table 1 compared the proposed electrode for amoxicillin determination with electrodes reported in literatures. As show, the proposed electrode comparable with other electrodes such as multiwalled carbon nanotube-modified glassy carbon electrode.

Table 1.Analytical parameters of several modified electrodes for AMX determination. LOD: limit of detection; LDR: linear dynamic range; CPE: carbon paste electrode; SWV: square wave voltammetry

 

CONCLUSION

A new modified CIM-SGD-CC electrode was fabricated by sol−gel technique. The modied electrode exhibits excellent and persistent electrocatalytic behavior toward amoxicillin oxidation compared with the bare CCE. The kinetic parameters such as electron transfer coefcient and catalytic reaction rate constant were also determined using electrochemical approaches. High stability, good reproducibility, short response time, long-term stability, high sensitivity, easy surface regeneration and fabrication are the important characteristics of the proposed electrode.

References

  1. Langin, A.; Alexy, R.; Konig, A.; Kummerer, K. Chemosphere 2009, 75, 347. https://doi.org/10.1016/j.chemosphere.2008.12.032
  2. Uslu, B.; Biryol, I. J. Pharm. Biomed. Anal. 1999, 20, 591. https://doi.org/10.1016/S0731-7085(99)00059-X
  3. Rezaei, B.; Damiri, S; Electroanalysis 2009, 14, 1577.
  4. Santos, D. P.; Márcio, F.; Bergamini, M.; Zanoni, V. B. Sens. Actuators, B 2008, 133, 398. https://doi.org/10.1016/j.snb.2008.02.045
  5. Biryol, I.; Uslu, B.; Kuc, Z.; ukyavuz, S. T. P. Pharma Sci. 1998, 8, 383.
  6. Riviere, J. E.; Craigmill, A. L.; Sundlof, S. F. Handbook of Comparative Pharmacokinetics and Residues of Veterinary Antimicrobials; CRC Press: Boca Raton, FL, 1991.
  7. Bergamini, M. F.; Teixeira, M. F. S.; Dockal, E. R.; Bocchi, N.; Cavalheiro, E. T. G. J. Electrochem. Soc. 2006, 153, 94.
  8. Ojani, R.; Raoof, J. B.; Zamani, S. Bioelectrochem. 2012, 85, 44. https://doi.org/10.1016/j.bioelechem.2011.11.010
  9. Xu, Q.; Zhao, Y.; Xu, J. Z.; Zhu, J. J. Sens. Actuators, B 2006, 114, 379. https://doi.org/10.1016/j.snb.2005.06.005
  10. Tsionsky, M.; Gun, J.; Glezer, V.; Lev, O. Anal. Chem. 1994, 66, 1747. https://doi.org/10.1021/ac00082a024
  11. Karim-Nezhad, G.; Seyed Dorraji, P. Electrochim. Acta 2010, 55, 3414. https://doi.org/10.1016/j.electacta.2010.01.057
  12. Karim-Nezhad, G.; Zare Dizajdizi, B.; Seyed Dorraji, P. Catal. Commun. 2011, 12, 906. https://doi.org/10.1016/j.catcom.2011.02.009
  13. Harrison, J. A.; Khan, Z. A. J. Electroanal. Chem. 1970, 28, 131. https://doi.org/10.1016/S0022-0728(70)80288-1
  14. Bard, A. J.; Faulkner, L. R. Electrochemical Methods; Wiley: New York, 2001; p 591.
  15. Karim-Nezhad, G.; Jafarloo, R.; Seyed Dorraji, P. Electrochim. Acta 2009, 54, 5721. https://doi.org/10.1016/j.electacta.2009.05.019
  16. Hasanzadeh, M.; Karim-Nezhad, G.; Shadjou, N.; Khalilzadeh, B.; Saghatforoush, L. A.; Earshad, S.; Kazeman, I. Chin. J. Chem. 2009, 27, 638. https://doi.org/10.1002/cjoc.200990104
  17. Zheng, L.; Song, J. J. Appl. Electrochem. 2011, 41, 63. https://doi.org/10.1007/s10800-010-0207-6
  18. Shafieyan, H.; Rouhollahi, A. Anal. Bioanal. Electrochem. 2010, 2, 13.
  19. Santos, D. P.; Bergamini, M. F.; Zanoni, M. V. B. Sens. Actuators, B 2008, 133, 398. https://doi.org/10.1016/j.snb.2008.02.045

Cited by

  1. Electrochemical Determination of Amoxicillin on a Poly(Acridine Orange) Modified Glassy Carbon Electrode vol.49, pp.9, 2016, https://doi.org/10.1080/00032719.2015.1101602
  2. Electrochemical sensor for amoxicillin using Cu/poly (o-toluidine) (sodium dodecyl sulfate) modified carbon paste electrode vol.52, pp.1, 2016, https://doi.org/10.1134/S1023193516010067
  3. Development of a new modified carbon paste electrode by silver chloride: application to electrocatalytic oxidation of methanol vol.13, pp.2, 2016, https://doi.org/10.1007/s13738-015-0738-1
  4. Zn-mesoporous metal-organic framework incorporated with copper ions modified glassy carbon electrode: Electrocatalytic oxidation and determination of amoxicillin vol.164, pp.None, 2013, https://doi.org/10.1016/j.microc.2021.106011