DOI QR코드

DOI QR Code

Development of a Smartphone-based Pupillometer

  • Kim, Tae-Hoon (Department of Biomedical Engineering, College of Medical Science, Catholic University of Daegu) ;
  • Youn, Jong-In (Department of Biomedical Engineering, College of Medical Science, Catholic University of Daegu)
  • Received : 2013.02.01
  • Accepted : 2013.04.19
  • Published : 2013.06.25

Abstract

In ophthalmology, a pupillometer, a device to measure the diameter of the pupil of the eye, can provide information on the function of the autonomic nervous system. The current pupillometers on the market are either too large to be a handheld instrument, or relatively expensive. In this study, a pupillometer based on a smartphone was designed. Both white and infrared LEDs and a 3M pixel camera of a smartphone were applied for the visual stimuli to an eye and for the acquisition of the eye images, respectively. Contrary to the existing method of pupil measurement that usually observe the variation of pupil diameter, the proposed algorithm in this study was applied to calculate the constriction ratio of the pupillary area in response to pupillary light reflex. The results showed that the constriction ratio of the pupillary area were all in the normal range (above 4.0) from the sixteen healthy participants. It is believed that the approach to pupil measurement used in this study is suitable for a mobile interface, and this system can be applied to clinical research, home-use healthcare, and distributed to some areas which suffer from problems like a lack of medical support.

Keywords

References

  1. J. L. Barbur, "Learning from the pupil - studies of basic mechanisms and clinical applications," The Visual Neurosciences 1, 641-656 (2004).
  2. A. D. Santis and D. Iacovelllo, "Optimal segmentation of pupillometric images for estimating pupil shape parameters," Comput. Methods Programs Biomed. 84, 174-187 (2006). https://doi.org/10.1016/j.cmpb.2006.07.005
  3. E. Granholm, S. Morris, D. Galasko, C. Shults, E. Rogers, and B. Vukov, "Tropicamide effects on pupil size and pupillary light reflexes in Alzheimer's and Parkinson's disease," Int. J. Psychophysiol. 47, 95-115 (2003). https://doi.org/10.1016/S0167-8760(02)00122-8
  4. T. Sugiyama and T. Utsumi, "Pupillary dynamics in Parkinson's disease," Neuroophthalmology 10, 1-7 (1990). https://doi.org/10.3109/01658109008997254
  5. J. Martineau, N. Hernandez, L. Hiebel, L. Roche, A. Metzger, and F. Bonnet-Brilhault, "Can pupil size and pupil responses during visual scanning contribute to the diagnosis of autism spectrum disorder in children?," Journal of Psychiatric Research 45, 1077-1082 (2011). https://doi.org/10.1016/j.jpsychires.2011.01.008
  6. D. Pittasch, R. Lobmann, W. Behrens-Baumann, and H. Lehnert, "Pupil signs of sympathetic autonomic neuropathy in patients with type 1 diabetes," Diabetes Care 25, 1545-1550 (2002). https://doi.org/10.2337/diacare.25.9.1545
  7. B. S. B. Wachler and R. R. Krueger, "Agreement and repeatability of infrared pupillometry and comparison method," Ophthalmology 106, 319-323 (1999). https://doi.org/10.1016/S0161-6420(99)90070-2
  8. M. D. Twa, M. D. Bailey, J. Hayes, and M. Bullimore, "Estimation of pupil size by digital photography," J. Cataract Refract. Surg. 30, 381-389 (2004). https://doi.org/10.1016/S0886-3350(03)00619-9
  9. E. M. Schnitzler, M. Baumeister, and T. Kohnen, "Scotopic measurement of normal pupils - colvard versus video vision analyzer infrared pupillometer," J. Cataract Refract. Surg. 26, 859-866 (2000). https://doi.org/10.1016/S0886-3350(00)00486-7
  10. M. Pop, Y. Payette, and E. Santoriello, "Comparison of the pupil card and pupillometer in measuring pupil size," J. Cataract Refract. Surg. 28, 283-288 (2002). https://doi.org/10.1016/S0886-3350(01)01222-6
  11. H. Wilhelm and B. Wilhelm, "Clinical applications of pupillography," Journal of Neuro-ophthalmology 23, 42-49 (2003). https://doi.org/10.1097/00041327-200303000-00010
  12. C. Doukas and I. Maglogiannis, "A fast mobile face recognition system for android OS based on Eigenfaces decomposition," in Proc. Artificial Intelligence Applications and Innovations (Larnaca, Cyprus, Oct 2010), AICT 339, pp. 295-302.
  13. A. Koschan and M. Abidi, "A comparison of median filter techniques for noise removal in color images," in Proc. Seventh German Workshop on Color Image Processing (Erlangen, Germany, 2001), pp. 69-79.
  14. A. Jeffrey, Handbook of Mathematical Formulas and Integrals (Academic Press, 1995).
  15. E. Granholm, S. Morris, D. Galasko, C. Shults, E. Rogers, and B. Vukov, "Tropicamide effects on pupil size and pupillary light reflexes in Alzheimer's and Parkinson's disease," Int. J. Psychophysiol. 47, 95-115 (2003). https://doi.org/10.1016/S0167-8760(02)00122-8
  16. R. Prettyman, P. Bitsios, and E. Szabadi, "Altered pupil size and darkness and light reflexes in Alzheimer's disease," J. Neurol. Neurosurg. Psychiatry 62, 665-668 (1997). https://doi.org/10.1136/jnnp.62.6.665
  17. X. Fan, J. H. Miles, N. Takahashi, and G. Yao, "Abnormal transient pupillary light reflex in individuals with autism spectrum disorders," Journal of Autism and Developmental Disorders 39, 1499-1508 (2009). https://doi.org/10.1007/s10803-009-0767-7
  18. O. Bergamin, M. B. Zimmerman, and R. H. Kardon, "Pupil light reflex in normal and diseased eyes: diagnosis of visual dysfunction using waveform partitioning," Ophthalmology 110, 106-114 (2003). https://doi.org/10.1016/S0161-6420(02)01445-8
  19. S. F. Pilley and H. S. Thompson, "Pupillary "dilatation lag" in Horner's syndrome," Br. J. Ophthalmol. 59, 731-735 (1975). https://doi.org/10.1136/bjo.59.12.731
  20. K. Karavanaki, A. G. Davies, L. P. Hunt, M. H. Morgan, and J. D. Baum, "Pupil size in diabetes," Archives of Disease in Childhood 71, 511-515 (1994). https://doi.org/10.1136/adc.71.6.511
  21. H. J. Wyatt, "The form of the human pupil," Vision Research 35, 2021-2036 (1995). https://doi.org/10.1016/0042-6989(94)00268-Q
  22. P. Francus, F. Keimig, and M. Besonen, "An algorithm to aid varve counting and measurement from thin-sections," J. Paleolimnol. 28, 283-286 (2002). https://doi.org/10.1023/A:1021624415920
  23. M. M. Lavezzo, S. A. Schellini, C. B. Padovani, and F. E. Hirai, "Evaluation of pupillary diameter in preschool children," Neuro-ophthalmology 33, 313-317 (2009). https://doi.org/10.3109/01658100903360346
  24. X. He and P. Shi, "A new segmentation approach for iris recognition based on hand-held capture device," Pattern Recognition 40, 1326-1333 (2007). https://doi.org/10.1016/j.patcog.2006.08.009
  25. B. U. Ko, W. Y. Ryu, and W. C. Park, "Pupil size in the normal Korean population according to age and illuminance," J. Korean Ophthalmol. Soc. 52, 401-406 (2011). https://doi.org/10.3341/jkos.2011.52.4.401
  26. R. Spector, Clinical Methods, 3rd ed. (Butterworths, 1990).
  27. M. F. Pasha, S. Supramaniam, K. K. Liang, M. A. Amran, B. A. Chandra, and M. Rajeswari, "An android-based mobile medical image viewer and collaborative annotation: development issues and challenges," JDCTA 6, 208-217 (2012).

Cited by

  1. Evaluation of Mobile Phone Performance for Near-Infrared Fluorescence Imaging vol.64, pp.7, 2017, https://doi.org/10.1109/TBME.2016.2601014