DOI QR코드

DOI QR Code

Study of the ageing of hollow fibers in an industrial module for drinking water production

  • Wang, S. (Aix Marseille Universite, Laboratoire de Mecanique, Modelisation et Procedes Propres (M2P2 - UMR-CNRS 7340)) ;
  • Wyart, Y. (Aix Marseille Universite, Laboratoire de Mecanique, Modelisation et Procedes Propres (M2P2 - UMR-CNRS 7340)) ;
  • Perot, J. (SAUR) ;
  • Nauleau, F. (SAUR) ;
  • Moulin, P. (Aix Marseille Universite, Laboratoire de Mecanique, Modelisation et Procedes Propres (M2P2 - UMR-CNRS 7340))
  • 투고 : 2012.07.19
  • 심사 : 2013.01.22
  • 발행 : 2013.01.25

초록

In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).

키워드

참고문헌

  1. Choi, S., Yang, J. Suh, C. and Cho, J. (2011), "Use of fluorescent silica particles for checking the integrity of microfiltration membranes", J. Membrane Sci., 367(1-2), 306-313. https://doi.org/10.1016/j.memsci.2010.11.015
  2. DiLeo, A. and Phillips, M. (1995), "Process for evaluating solute retention characteristics of membranes", US Pate As for the previously used modules, the same observations and the same conclusions can be made regarding the evolution of the magnetic susceptibility in the feed (presence of PAC). nt 5,457,986.
  3. Daurelle, J.V., Q. Derekx, Y. Wyart, K. Glucina and P. Moulin (2011), Use of advanced CFD tool to characterize hydrodynamic of commercial UF membrane module, 8th IWA Leading Edge Amsterdam, Netherland, 8-10 Juin
  4. Fauconnier, N., Pons, J.N. Roger, J. and Bee, A. (1997), "Thiolation of maghemite nanoparticles by dimercaptosuccinic acid", J. Colloid Inter. Sci., 194(2), 427-433. https://doi.org/10.1006/jcis.1997.5125
  5. Giglia, S. and Krishnan, M. (2008), "High sensitivity binary gas integrity test for membrane filters", J. of Membrane Sci., 323(1), 60-66. https://doi.org/10.1016/j.memsci.2008.06.017
  6. Guo, H., Wyart, Y. Perot, J. Nauleau, F. and Moulin, P. (2010), "Application of magnetic nanoparticles for ultrafiltration membrane integrity monitoring at low-pressure operation", J. of Membrane Sci., 350(1-2), 172-179. https://doi.org/10.1016/j.memsci.2009.12.025
  7. Guo, H., Wyart, Y. Perot, J. Nauleau, F. and Moulin, P. (2010), "Low-pressure membrane integrity tests for drinking water treatment: A review", Water Res., 44(1), 41-57. https://doi.org/10.1016/j.watres.2009.09.032
  8. La, J.M., Glucina, K. Chamant, M. and Simonie, P. (1998), "Acoustic sensor: a novel technique for low pressure membrane integrity monitoring", Desalination, 119(1-3), 73-77. https://doi.org/10.1016/S0011-9164(98)00111-8
  9. Moulin, P. (2008) Patent Number(s): FR2901607-A1; EP1862791-A2.
  10. Suh, C., Choi, B. Lee, S. Kim, D. and Cho, J. (2011), "Application of genetic programming to develop the model for estimating membrane damage in the membrane integrity test using fluorescent nanoparticle", Desalination, 281(17), 80-87. https://doi.org/10.1016/j.desal.2011.07.045
  11. Phattaranawik, J., Fane, A.G. and Wong, F.S. (2008), "Novel membrane-based sensor for online membrane integrity monitoring", J. Membrane Sci., 323(1), 113-124. https://doi.org/10.1016/j.memsci.2008.06.008
  12. Walsh, M.E., Chaulk, M.P. and Gagnon, G.A. (2005), "Indirect integrity testing on a pilot-scale ultrafiltration membrane", J. Water Supply: Research and Technology., AQUA 54, 105-114.

피인용 문헌

  1. Analysis of performance criteria for ultrafiltration membrane integrity test using magnetic nanoparticles vol.353, 2014, https://doi.org/10.1016/j.desal.2014.09.004