참고문헌
- Choi, S., Yang, J. Suh, C. and Cho, J. (2011), "Use of fluorescent silica particles for checking the integrity of microfiltration membranes", J. Membrane Sci., 367(1-2), 306-313. https://doi.org/10.1016/j.memsci.2010.11.015
- DiLeo, A. and Phillips, M. (1995), "Process for evaluating solute retention characteristics of membranes", US Pate As for the previously used modules, the same observations and the same conclusions can be made regarding the evolution of the magnetic susceptibility in the feed (presence of PAC). nt 5,457,986.
- Daurelle, J.V., Q. Derekx, Y. Wyart, K. Glucina and P. Moulin (2011), Use of advanced CFD tool to characterize hydrodynamic of commercial UF membrane module, 8th IWA Leading Edge Amsterdam, Netherland, 8-10 Juin
- Fauconnier, N., Pons, J.N. Roger, J. and Bee, A. (1997), "Thiolation of maghemite nanoparticles by dimercaptosuccinic acid", J. Colloid Inter. Sci., 194(2), 427-433. https://doi.org/10.1006/jcis.1997.5125
- Giglia, S. and Krishnan, M. (2008), "High sensitivity binary gas integrity test for membrane filters", J. of Membrane Sci., 323(1), 60-66. https://doi.org/10.1016/j.memsci.2008.06.017
- Guo, H., Wyart, Y. Perot, J. Nauleau, F. and Moulin, P. (2010), "Application of magnetic nanoparticles for ultrafiltration membrane integrity monitoring at low-pressure operation", J. of Membrane Sci., 350(1-2), 172-179. https://doi.org/10.1016/j.memsci.2009.12.025
- Guo, H., Wyart, Y. Perot, J. Nauleau, F. and Moulin, P. (2010), "Low-pressure membrane integrity tests for drinking water treatment: A review", Water Res., 44(1), 41-57. https://doi.org/10.1016/j.watres.2009.09.032
- La, J.M., Glucina, K. Chamant, M. and Simonie, P. (1998), "Acoustic sensor: a novel technique for low pressure membrane integrity monitoring", Desalination, 119(1-3), 73-77. https://doi.org/10.1016/S0011-9164(98)00111-8
- Moulin, P. (2008) Patent Number(s): FR2901607-A1; EP1862791-A2.
- Suh, C., Choi, B. Lee, S. Kim, D. and Cho, J. (2011), "Application of genetic programming to develop the model for estimating membrane damage in the membrane integrity test using fluorescent nanoparticle", Desalination, 281(17), 80-87. https://doi.org/10.1016/j.desal.2011.07.045
- Phattaranawik, J., Fane, A.G. and Wong, F.S. (2008), "Novel membrane-based sensor for online membrane integrity monitoring", J. Membrane Sci., 323(1), 113-124. https://doi.org/10.1016/j.memsci.2008.06.008
- Walsh, M.E., Chaulk, M.P. and Gagnon, G.A. (2005), "Indirect integrity testing on a pilot-scale ultrafiltration membrane", J. Water Supply: Research and Technology., AQUA 54, 105-114.
피인용 문헌
- Analysis of performance criteria for ultrafiltration membrane integrity test using magnetic nanoparticles vol.353, 2014, https://doi.org/10.1016/j.desal.2014.09.004