References
- 최진호, 엄정섭, "해외 사례분석을 통한 Cool Roof의 도입 방안", 2010, 환경영향평가. 19(6), p. 591-605 / (Choijinho, Umjungsup, Introducing strategy of cool roofs based on comparative evaluation of foreign cases, Journal of Environmental Impact Assessment, 2010, 19(6), p. 591-605)
- Gu L, Cummings JE, Swami MV, Fairey P, Awwad S. Comparison of dust system computer models that could provide input to the thermal distribution standard method(SPC-152P), 1996, FSEC -CR-929-96.
- Akbari H, Konopacki S. Energy effects of heat-island reduction strategies in Toronto, Canada, Energy 2004, 29, pp. 191-210. https://doi.org/10.1016/j.energy.2003.09.004
- Akbari H. Cool roofs save energy, ASHRAE Transactions, 1998, 104, 1B, p. 783-788.
- Konopacki S, Akbari H. Simulated Impact of Roof Surface Solar Absorptance, Attic, and Duct Insulation on Coolingand Heating Energy Use in Single-Family New Residential Buildings, 1998, LBNL-41834, Lawrence Berkeley National Laboratory,Berkeley, CA.
- Hildebrandt E, Bos W, Moore R. Assessing the impacts of white roofs on building energy loads, ASHRAE Technical Data Bulletin, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA, 1998, 14(2), p. 28-36.
- Konopacki S, Akbari H. Measured Energy Savings and Demand Reduction from a Reflective Roof Membrane on a Large Retail Store in Austin, LBNL-47149, Lawrence Berkeley National Laboratory, Berkeley, CA,2001.
- Bohm B, Danig PO. Monitoring the energy consumption in a district heated apartment building in copenhagen, with specific interest in the thermodynamic performance, Energy and Buildings, 2004, 36(3), p. 229-236. https://doi.org/10.1016/j.enbuild.2003.11.006
- 장윤성, 엄창득, 박준호, 이전제, 박주생, 여환명, "적외선 열화상과 온도차비율법을 이용한 목조 주택의 열환경평가", 목재공학, 2010, 38(6), p. 518-525 / (Jangyunsung, Umchangdeuk, Parkjunho, Leejeonje, Parkjusaeng, Yeohwanmyung, Thermal environment evaluation of wooden house using infra-red thermal image and temperature difference ratio(TDR), The korean society of wood science technology, 2010, 38(6), p. 518-525)
- 기상청, 2012 / (KMA, 2012, Korea Meteorological Administration), http://www.kma.go.kr/
- Synnefa A, Santamouris M. Advances on technical, policy and market aspects of cool roof technology in Europe: The Cool Roofs project, Energy and Buildings, 2012, 55, p. 35-41. https://doi.org/10.1016/j.enbuild.2011.11.051
- Levinson R, Akbari H, Reilly J. Cooler tile-roofed buildings with near-infrared-reflective non-white coatings, Building and Environment, 2007, 42, p. 2591-2605. https://doi.org/10.1016/j.buildenv.2006.06.005
- 김 옥, "Cool Roof 시스템의 성능기준 및 설계지침에 관한 연구", 2010, 박사학위 논문 / (Kimok, A study on the performance standards and design guidelines of cool roof system, 2010, Thesis, Chung-ang University)
Cited by
- Performance evaluation strategy for cool roof based on pixel dependent variable in multiple spatial regressions vol.25, pp.2, 2017, https://doi.org/10.1007/s41324-017-0099-1