DOI QR코드

DOI QR Code

알칼리 용액이 수소배관으로 사용되는 Stainless steel에 미치는 영향 분석

An Analysis on Stainless Steel for Hydrogen Generator' Pipeline Interacting with Alkaline Solution

  • 변창섭 (포항공과대학교 나노기술집적센터) ;
  • 최진영 (이엠코리아주식회사 에너지사업부) ;
  • 임수곤 (이엠코리아주식회사 에너지사업부) ;
  • 황갑진 (호서대학교) ;
  • 최호상 (경일대학교) ;
  • 신훈규 (포항공과대학교 나노기술집적센터)
  • Byun, Chang-Sub (National Center for Nanomaterials Technology, Pohang University of Science and Technology) ;
  • Choi, Jin-Young (EM KOREA CO., LTD.) ;
  • Lim, Soo-Gon (EM KOREA CO., LTD.) ;
  • Hwang, Gab-Jin (Convergence Technology Research Institute, Hoseo University) ;
  • Choi, Ho-Sang (Department of Chemical Engineering, Kyungil University) ;
  • Shin, Hoon-Kyu (National Center for Nanomaterials Technology, Pohang University of Science and Technology)
  • 투고 : 2012.04.27
  • 심사 : 2012.06.22
  • 발행 : 2012.06.30

초록

This study was performed to observe the change of stainless steel pipe interacting with alkaline solution. We used STS316L and STS304 as samples which were soaked in alkaline solution. We measured the samples by use of FE-SEM, EDX, SIMS to observe the surface and depth profile of both samples. The result showed that the precipitate appeared on the surface of both samples from 5 days. but the precipitate was confirmed to be decreased as time passes. but the quantitative change of precipitates at both samples was different as time passed. The EDX showed that the precipitate is Potassium from solution of Electrolysis. The result also showed that the primary elements of stainless steel pipeline and of Alkaline Solution were changed. The change of primary elements was severe between 5 days to 16 days and was stable around 40 days at both samples. The reaction of STS316L with alkaline solution was lower than STS304. We hoped that this study would be the foundation of developing the electrode of the alkaline hydrogen generator.

키워드

참고문헌

  1. J.K Jeon, "Problem of corrosion in Hydrogen Generator", J. KIChE, Vol. 8, No 3, 1970. pp. 136-140.
  2. H.S Choi, Gab-Jin Hwang, Young-Gwan Jung, "Hydrogen Energy", A-JIN Publishing Co., Ltd, Seoul, 2005, pp. 15-102.
  3. G. W. Whitman, R. P. Russell, and V. J. Altieri, "Effect of Hydrogen-Ion Concentration on the Submerged Corrosion of Steel", Industrial and Engineering chemistry, Vol. 16, No. 7, 1924, pp. 665-670. https://doi.org/10.1021/ie50175a002
  4. Ehteram A. Noor. "Potential of aqueous extract of Hibiscus sabdariffa leaves for inhibiting the corrosion of aluminum in alkaline solution", J. Appl. Electrochem, 2009, pp. 1465-1475.
  5. S.Y Park, S.J Nam, "The effect of Drag-reducing Surfactant on Corrosion in Transportation Pipe", SAREK, Collection of dissertations in 98 Winter scholarship Meeting, pp. 370-375.
  6. Gab-Jin, H.S Choi, C.S Byun, "Study on Anion Exchange Membrane for the Alkaline Electrolysis", Trans. of the Korean Hydrogen and New Energy Society, Vol. 22, No. 2, 2011, pp. 184-190.
  7. S. Sathiyanarayanan, M. Sahre, W. Kautek, "In-Situ grazing incidence X-ray diffractometry observation of pitting corrosion of copper in chloride solutions", Corrosion Science, Vol. 41, 1999, pp. 1899-1909. https://doi.org/10.1016/S0010-938X(99)00021-9
  8. Kwan-Hyung Jo, Sun-Ii Kim, Dal-Sik Woo, "Effect of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion", Kor. J. Env. Hlth, Vol. 33, No. 1, 2007, pp. 43-48.
  9. C.W.Du, X.G.Li, P. Liang, "Effects of Microstructure on Corrosion of X70 Pipe Steel in an alkaline Soil", Journal of Materials Engineering and Performance, Vol. 18, No. 2, 2009, pp. 216-220. https://doi.org/10.1007/s11665-008-9280-y

피인용 문헌

  1. Analysis on Variation of Primary Elements of Stainless Steel Interacting with Alkali Solution vol.26, pp.7, 2013, https://doi.org/10.4313/JKEM.2013.26.7.522
  2. A Study on the Variation of Anion Exchange Membrane of Hydrogen Generator of Alkaline Electrolysis vol.26, pp.7, 2013, https://doi.org/10.4313/JKEM.2013.26.7.563