DOI QR코드

DOI QR Code

Determination of plastic hinge properties for static nonlinear analysis of FRP-strengthened circular columns in bridges

  • Amiri, Gholamreza Ghodrati (Center of Excellence for Fundamental Studies in Structural Engineering, School of Civil Engineering, Iran University of Science & Technology) ;
  • Jahromi, Azadeh Jaberi (School of Civil Engineering, Iran University of Science & Technology) ;
  • Mohebi, Benyamin (Department of Civil engineering, Faculty of Engineering, Imam Khomeini International University)
  • Received : 2010.07.07
  • Accepted : 2011.11.23
  • Published : 2012.11.25

Abstract

In the recent years, rehabilitation of structures, strengthening and increasing the ductility of them under seismic loads have become so vital that many studies has been carried out on the retrofit of steel and concrete members so far. Bridge piers are very important members concerning rehabilitation, in which the plastic hinging zone is very vulnerable. Pier is usually confined by special stirrups predicted in the design procedure; moreover, fiber-reinforced polymers (FRP) jackets are used after construction to confine the pier. FRP wrapping of the piers is one of the most effective ways of increasing moment and ductility capacity of them, which has a growing application due to its relative advantages. In many earthquake-resistant bridges, reinforced concrete columns have a major defect which could be retrofitted in different ways like using FRP. After rehabilitation, it is important to check the strengthening adequacy by dynamic nonlinear analysis and precise modeling of material properties. If the plastic hinge properties are simplified for the strengthened members, as the simplified properties which FEMA 356 proposes for non-strengthened members, static nonlinear analysis could be performed more easily. Current paper involves this matter and it is intended to determine the plastic hinge properties for static nonlinear analysis of the FRP-strengthened circular columns.

Keywords

References

  1. AASHTO (2002), Standard specification for highway bridges, 17th Edition, American Association of State Highway and Transportation Officials, Washington D.C.
  2. ANSYS Standard Users Manual Help, Ver.11 and ANSYS Structural Nonlinearities Manual.
  3. ACI Committee 440 (1996), State-of-the-art report on FRP for concrete structures(ACI 440R-96), Manual of Concrete Practice, American Concrete Institute, Farmington with Hills, Michigan, 68.
  4. ACI Committee 440 (2000), Guide for the design and construction of externally bounded FRP systems for strengthening concrete structures, ACI Code, Reported by ACI Committee 440.
  5. ATC40 (1997), Seismic evaluation and retrofit of concrete buildings.
  6. Bank, L.C. (2006), Composites for construction, structural design with FRP materials, John Wiley and Sons Inc, Hobokel, New Jersey, Canada.
  7. Challal, O., Hassan, M. and Shahawy, M. (2003), "Confinement model for axially loaded short rectangular columns strengthened with fiber reinforced polymer wrapping", ACI Struct. J., 100(2), 215-221.
  8. Chen, W.F. (1994), Constitutive equations for engineering materials, Elsevier Science, 2(1), 1096.
  9. Fam, A.Z. and Rizkalla, S.H. (2001), "Confinement model for axially loaded concrete confined by circular fiber reinforced polymer tubes", ACI Struct. J., 98(4), 451-461.
  10. Fardis, M.N. and Khalili, H. (1981), "Concrete encased in fiberglass reinforced plastic", ACI J., 76(6), 440-446.
  11. FEMA 356 (2000), NEHRP Recommended provisions for the seismic rehabilitation of buildings.
  12. FEMA 440 (2005), NEHRP Recommended provisions for the improvement of nonlinear static seismic analysis procedures.
  13. FHWA (1995), Seismic retrofit manual for highway bridges, Publication No. FHWA/RD-052, McLean, VA.
  14. Hoshikuma, J., Kawashima, K., Nagaya, K. and Taylor, W. (1997), "Stress-strain model for confined reinforced concrete in bridge piers", J. Struct. Eng.-ASCE, 123(5), 624-633. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:5(624)
  15. Inel, M. and Ozmen, H.B. (2006), "Effect of plastic hinge properties in nonlinear analysis of reinforced concrete buildings", Eng. Struct., 28(11), 1494-1502. https://doi.org/10.1016/j.engstruct.2006.01.017
  16. Karbhari, V.M. and Gao, Y. (1997), "Composite jacketed concrete under uniaxial compression _Verification of simple design equations", J. Mater. Civil Eng., 9(4), 185-193. https://doi.org/10.1061/(ASCE)0899-1561(1997)9:4(185)
  17. Lee, J. and Fenves, G.L. (1998), "Plastic-damage model for cyclic loading of concrete structures", J. Eng. Mech., 124(8), 892-900. https://doi.org/10.1061/(ASCE)0733-9399(1998)124:8(892)
  18. Li, Y.F., Lin, C.T. and Sung, Y.Y. (2003), "A constitutive model for concrete confined with carbon fiber reinforced plastics", Mech. Mater., 35(3-6), 603-619. https://doi.org/10.1016/S0167-6636(02)00288-0
  19. Li, Y.F. and Fang, T.S. (2004), "A constitutive model for concrete confined by steel reinforcement and carbon fiber reinforced plastic sheet", Struct. Eng. Mech., 18(1), 21-40. https://doi.org/10.12989/sem.2004.18.1.021
  20. Li, Y.F. and Sung, Y.Y. (2004), "A study on the sheer-failure of circular sectioned bridge column retrofitted by using CFRP jacketing", J. Reinf. Plast. Comp., 23(8), 811-830. https://doi.org/10.1177/0731684404032865
  21. Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng.-ASCE, 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  22. Mirmiran, A., Zagers, K. and Yuan, W. (2000), "Nonlinear finite element modeling of concrete confined by fiber composites", Finite Elem. Anal. Des., 35(1), 79-96. https://doi.org/10.1016/S0168-874X(99)00056-6
  23. Mirmiran, A. and Shahawy, M. (1997), "Behavior of concrete columns confined by fiber composites", J. Struct. Eng.-ASCE, 123(5), 583-590. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:5(583)
  24. Perera, R. (2006), "A numerical model to study the seismic retrofit of RC columns with advances Composite Jacketing", Compos. Part B.-Eng., 37(4-5), 337-345. https://doi.org/10.1016/j.compositesb.2005.11.001
  25. Saatcioglu, M. and Razvi, S. (1992), "Strength and ductility of confined concrete", J. Struct. Div.-ASCE, 118(6), 1590-1607. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:6(1590)
  26. Saafi, M., Toutanji, H. and Li, Z. (1999), "Behavior of concrete columns confined with reinforced polymer tubes", ACI Mater. J., 96(4), 500-509.
  27. Samaan, M., Mirmiran, A. and Shahawy, M. (1998), "Model of concrete confined by fiber composites", J. Struct. Eng.-ASCE, 124(9), 1025-1031. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:9(1025)
  28. Sarrazin, J. (2004), A Comparative analysis of seismic retrofit techniques for reinforced concrete bridge columns, PHD Thesis, University of Ottawa, Canada.
  29. Shahawy, M., Mirmiran, A. and Beitelman, T. (2000), "Tests and modeling of carbon wrapped concrete columns", Compos. Part B.-Eng., 31(6-7), 471-480. https://doi.org/10.1016/S1359-8368(00)00021-4
  30. Sheikh, S.A. and Uzumeri, S.M. (1980), "AnalytIcal model for concrete confinement in tied columns", J. Struct. Div.-ASCE, 108(12), 2073-2722.
  31. Syngros, C., Mylonakis, G. and Gazetas, G. (2004), "Geotechnical effects in the collapse of Fukae (Hanshin Expressway) Bridge, Kobe, 1995", Yegian, M.K., and Kavazanjian, E., - Editors, July 27-31, 2004 Los Angeles, California, USA, Geotechnical Engineering for Transportation Projects (GPS No. 126) 2004 ASC.
  32. Toutanji, H. (1999), "Stress-strain characteristics of concrete columns externally confined with advances fiber Composite sheets", ACI Mater. J., 96(3), 397-404.
  33. Vistaps, M. Karbhari (2004), "Fiber reinforced composite bridge system - transition from the laboratory to the field", Compos. Struct., 66(1-4), 5-16. https://doi.org/10.1016/j.compstruct.2004.04.026
  34. Wakabayashi, M. (1986), Design of earthquake-resistant buildings, McGraw Hill: New York.
  35. Xiao, Y. and Wu, H. (2000), "Compressive behavior of concrete confined by carbon fiber Composite jackets", J. Mater. Civil Eng., 12(2), 139-146. https://doi.org/10.1061/(ASCE)0899-1561(2000)12:2(139)
  36. Youssef, M.N. (2003), Stress-strain model for concrete confined by FRP composites, PHD Thesis, University of California, Irvine.

Cited by

  1. Transverse reinforcement for confinement at plastic hinge of circular composite hollow RC columns vol.17, pp.3, 2016, https://doi.org/10.12989/cac.2016.17.3.387
  2. Plastic hinge characteristics of RC rectangular columns with Fiber Reinforced Polymer (FRP) vol.18, pp.6, 2016, https://doi.org/10.12989/cac.2016.18.6.853
  3. Plastic hinge characteristics of RC rectangular columns with Fiber Reinforced Polymer (FRP) vol.18, pp.4, 2012, https://doi.org/10.12989/cac.2016.18.4.853
  4. Structural analysis of a prestressed segmented girder using contact elements in ANSYS vol.20, pp.3, 2017, https://doi.org/10.12989/cac.2017.20.3.319
  5. Numerical simulation of the constructive steps of a cable-stayed bridge using ANSYS vol.69, pp.3, 2012, https://doi.org/10.12989/sem.2019.69.3.269