DOI QR코드

DOI QR Code

Lateral confining action of mortar-filled sleeve reinforcement splice

  • Kim, Hyong-Kee (Department of Architectural Engineering, Kangwon National University) ;
  • Lee, Sang-Ho (Department of Architectural Engineering, Hanzhong University)
  • Received : 2010.12.22
  • Accepted : 2012.01.10
  • Published : 2012.02.10

Abstract

Of the various methods of splicing reinforcing bar in reinforced concrete structure, mortar-filled sleeve reinforcement splice offers diverse benefits, not only in terms of structural performance but also for the construction process. Consequently, after the mortar-filled sleeve splices have been developed in recent years, research and development on these splices has been actively carried out, in order to evaluate its macro structural performance, such as its strength and stiffness, with the aim of enabling this system to be applied to construction in the field as early as possible. However, to make a proper evaluation on the overall structural performance of the mortar-filled sleeve reinforcing bar splice, it is of critical importance to understand the lateral confining action of the sleeve, which is known to affect the bond strength between the embedded bar and mortar in the sleeve. Accordingly, in this study, an experiment of monotonic loading and cyclic loading was conducted with a full-sized mortar-filled sleeve splice attaching strain gauges on the sleeve surface with experimental variables such as development length of bar, etc. Based on the test results, the effect of the lateral confining action of the sleeve was analyzed and considered in terms of the bond strength between the bar and mortar in this splice.

Keywords

References

  1. Ahn, B.K., Kim, H.K. and Park, B.M. (2003) "Confining effect of mortar grouted splice sleeve on reinforcing bar", J. Korea Concrete Institute, 15(1), 102-109. (in Korean) https://doi.org/10.4334/JKCI.2003.15.1.102
  2. Ase, M. et al. (1996) "Study for practical application of grout filled connectors for high strength reinforcing bars (No. 1 performance of the grout filled connector with SD490 reinforcing bars)", Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, C-2, Structures IV, 743-744. (in Japanese)
  3. Bing, L., Park, B. and Tanaka, H. (2001) "Stress-strain behavior of high-strength concrete confined by ultra-highand normal-strength transverse reinforcements", ACI Struct. J., 98(3), 395-406.
  4. Choi, Y.H., Kim, K.S. and Choi, S.M. (2008) "Simplified P-M interaction curve for square steel tube filled with high-strength concrete", Thin Wall. Struct., 46(2008), 506-515. https://doi.org/10.1016/j.tws.2007.10.008
  5. Cusson, D. and Paultre, P. (1994) "High-strength concrete columns confined by rectangular ties", J. Struct. Eng., ASCE, 120(3), 783-804. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:3(783)
  6. Cusson, D. and Paultre, P. (1995) "Stress-strain model for confined high-strength concrete", J. Struct. Eng., ASCE, 121(3), 468-477 https://doi.org/10.1061/(ASCE)0733-9445(1995)121:3(468)
  7. Einea, A., Yamane, T. and Tadros, M.K. (1995) "Grout-filled pipe splices for precast concrete construction", PCI J., 40(1), 82-93.
  8. Kilpatrick, A.E. and Rangan, B.V. (1999) "Tests on high-strength concrete-filled steel tubular columns", ACI Struct. J., 96(2), 268-274.
  9. Kim, H.K. (2008) "Structural performance of steel pipe splice for SD500 high-strength reinforcing bar under cyclic loading", Architect. Res., 10(1), 13-23.
  10. Kim, H.K. (2008) "Confining effect of mortar-filled steel pipe splice", Architect. Res., 10(2), 27-35.
  11. Liang, Q.Q. (2009) "Strength and ductility of high strength concrete-filled steel tubular beam-columns", J. Constr. Steel Res., 65, 687-698. https://doi.org/10.1016/j.jcsr.2008.08.005
  12. Liu, D. (2006) "Behaviour of eccentrically loaded high-strength rectangular concrete-filled steel tubular columns", J. Constr. Steel Res., 62, 839-846. https://doi.org/10.1016/j.jcsr.2005.11.020
  13. Liu, D. and Gho, W.L. (2005) "Axial load behaviour of high-strength rectangular concrete-filled steel tubular stub columns", Thin Wal. Struct., 43, 1131-1142. https://doi.org/10.1016/j.tws.2005.03.007
  14. Lue, D.M., Liu, J.L. and Yen, T. (2007) "Experimental study on rectangular CFT columns with high-strength concrete", J. Constr. Steel Res., 63, 37-44. https://doi.org/10.1016/j.jcsr.2006.03.007
  15. Mander, J.B., Priestley, J.N. and Park, R. (1988) "Theoretical stress-strain model for confined concrete", J. Struct. Eng., ASCE, 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  16. Mirmiran, A. and Shahawy, M. (1997) "Behavior of concrete columns confined by fiber composites", J. Struct. Eng., ASCE, 123(5), 583-590. https://doi.org/10.1061/(ASCE)0733-9445(1997)123:5(583)
  17. Orangun, C.O., Jirsa, J.O. and Breen, J.E. (1977) "A reevaluation of test data on development length and splices", ACI J., 74(3), 114-122.
  18. Park, J.W., Hong, Y.K. and Choi, S.M. (2010) "Behaviors of concrete filled square steel tubes confined by carbon fiber sheets (CFS) under compression and cyclic loads", Steel Compos. Struct., 10(2), 187-205. https://doi.org/10.12989/scs.2010.10.2.187
  19. Razvi, S.R. and Saatcioglu, M. (1999) "Confinement model for high-strength concrete", J. Struct. Eng., ASCE, 125(3), 281-289. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:3(281)
  20. Saadatmanesh, H., Ehsani, M.R. and Li, M.W. (1994) "Strength and ductility of concrete columns externally reinforced with fiber composite straps", ACI Struct. J., 91(4), 434-447.
  21. Saatcioglu, M. and Razvi, S.R. (1992) "Strength and ductility of confined concrete", J. Struct. Eng., ASCE, 118(6), 1590-1607. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:6(1590)
  22. Saatcioglu, M. and Razvi, S.R. (1998) "High-strength concrete columns with square sections under concentric compression", J. Struct. Eng., ASCE, 124(12), 1438-1447. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:12(1438)
  23. Soroushian, P., Choi, K.B., Park, G.H. and Aslani, F. (1991) "Bond of deformed bars to concrete: effects of confinement and strength of concrete", ACI Mater. J., 88(3), 227-232.
  24. Tao, Z., Han, L.H. and Wang, L.L. (2007) "Compressive and flexural behaviour of CFRP-repaired concrete-filled steel tubes after exposure to fire", J. Constr. Steel Res., 63, 1116-1126. https://doi.org/10.1016/j.jcsr.2006.09.007
  25. Untrauer, R.E. and Henry, R.L. (1965) "Influence of normal pressure on bond strength", ACI J., 62(5), 577-585
  26. Xiao, Y., He, W. and Choi, K.K. (2005) "Confined concrete-filled tubular columns", J. Struct. Eng., ASCE, 131(3), 488-497. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:3(488)

Cited by

  1. Mechanical Performance and Stress–Strain Relationships for Grouted Splices Under Tensile and Cyclic Loadings vol.10, pp.4, 2016, https://doi.org/10.1007/s40069-016-0156-5