DOI QR코드

DOI QR Code

Development of Force Sensors for Rectangular-Type Finger-Rehabilitation Robot Instruments and Their Characteristic Test

직교형 손가락 재활로봇기구를 위한 힘센서 개발 및 특성실험

  • Kim, Gab-Soon (Department of Control & Instrumentation Engineering, ERI, Gyeongsang National Unversity)
  • 김갑순 (경상대학교 제어계측공학과)
  • Received : 2011.11.25
  • Accepted : 2012.01.04
  • Published : 2012.03.31

Abstract

Stroke patients must do the rehabilitation exercise to recover their fingers' function using a rehabilitation robot. But the rehabilitation robots mostly have not the force sensors to control the applied force to each finger. Thus, in this paper, the development of a force sensor for thumb rehabilitation robot and four two-axis force sensors for four-finger rehabilitation robot were developed. The force sensor and four two-axis force sensors could be used to measure the applied force to each finger, and the forces could be used to control the applied forces to each sensor in rehabilitation exercise using in the rehabilitation robot. The developed sensors have non-linearlity error of less than 0.05 %, repeatability error of less than 0.03 %, and the interference error of two-axis force sensor is less than 0.2 %.

Keywords

References

  1. E.B. Brokaw, R.J. Holley, and P.S. Lum, "Hand spring operated movement enhancer(HandSOME) device for hand rehabilitation after stroke", Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE, pp. 5867-5870, 2010.
  2. Y. Ren, H.S. Park, and L.Q. Zhang, "Developing a whole-arm exoskeleton robot with hand opening and closing mechanism for upper limb stroke rehabilitation", Rehabilitation Robotics, 2009. ICORR 2009. IEEE International Conference on, pp. 761-765, 2009.
  3. L. Connelly, Y. Jia, M.L. Toro, M.E. Stoykov, R.V. Kenyon, and D.G. Kamper "A pneumatic glove and immersive virtual reality environment for hand rehabilitative training after stroke", Neural Systems and Rehabilitation Engineering, IEEE Transactions on, vol. 18, no. 5, pp. 551-559, 2010. https://doi.org/10.1109/TNSRE.2010.2047588
  4. M. Bouzit, G. Burdea, G. Popescu, and R. Boian, "The rutgers master II - New design force-feedback glove", IEEE/ASME Transactions on Mechatronics, vol. 7, no. 2, JUNE 2002.
  5. J.H. Kim, D.I. Kang, H.H. Shin, and Y.K. Park, "Design and analysis of a column type multicomponent force/moment sensor", Measurement: J. Int. Meas. Confederation, vol. 33, pp. 213-219, 2003. https://doi.org/10.1016/S0263-2241(02)00044-1
  6. K. Nagai, Y. Ito, M. Yazaki, K. Higuchi, and S. Abe, "Development of a small six-component force/torque sensor based on the double-cross structure", Journal of the Robotics Society of Japan, vol. 22, no. 3, pp. 361-369, 2004. https://doi.org/10.7210/jrsj.22.361
  7. G.S. Kim and H.J. Shin, "Development of intelligent robot's hand with three-axis finger force sensors for intelligent robot", Journal of Institute of Control, Robotics and Systems, vol. 15, no. 3, pp. 300-305, 2009. https://doi.org/10.5302/J.ICROS.2009.15.3.300
  8. Hyeon-Min Kim, Hi-Suk Shin, Joungwon Yoon, and Gab-Soon Kim, "Development of two-finger force measuring system to measure two-finger gripping force and its characteristic evaluation", Journal of Sensor Science and Technology, vol. 20, no. 3, pp. 172-177, 2011. https://doi.org/10.5369/JSST.2011.20.3.172
  9. Hyeon-Min Kim and Gab-Soon Kim, "Development of finger-force measuring system with three-axis force sensor for measuring a sphericalobject grasping force", J. Kor. Sensors Soc., vol. 19, no. 3, pp. 238- 245, 2010.
  10. ATI Industrial Automation, "Multi-axis forcre/ torque sensor", ATI Industrial Automation, pp.4-45, 2005.
  11. Bl Autotec, "BL sensor, multi-axis force/torque sensor(BL-FTS-E020)", BL AUTOTEC, pp. 5-50, 2003.
  12. G.S. Kim and J.W. Yoon, "Development of calibration system for multi-axis force/moment sensor and its uncertainty evaluation", KSPE, vol. 24, no. 10, pp. 91-98, 2007.