Abstract

The contact tip is higher the wear of resistance and the longer life are demanded to GMA welding process. In this study, four different contact tips with three different compositions by two wires were evaluated their wear resistance by measuring in every one hour the area of enlarged hole at the exit side during actual wleding. Experimental results clearly showed that the Cr-containing tips strengthened by precipitation hardening have much better resistance to wear than those made by work hardening. In addition, flux cored wire is excellent abrasion resistance test results showed. Based on these results, the domestic industry, the life of the contact tip to know will be used as basic data.

Keywords

References

  1. Kim, H. J., Kim, N. H., Kim, H. S., and Koh, J. H., 2003, "Reliability of Contact Tip for Gas Metal Arc Welding," Journal of KWS, Vol. 21, No. 7, pp. 9-17.
  2. Kim, N. H., Kim, H. J., Ryoo, H. S., and Koh, J. H., 2004, "Variation of Microstructure and Hardness of Contact Tips during GMA Welding," Journal of KWS, Vol 22, No. 1, pp. 43-49.
  3. Rudy, J. F., Brown, D. C., and Groth, W. G., 1996,"Study of Current Contact Tubes for Gas Metal Arc Welding," Welding Research Supplement, Vol. 8, pp. 374-378.
  4. Yamada, T., and Tanaka, O., 1987, "Fluctuation of the Wire Feeding Rate in Gas Metal Arc Welding," Welding Journal, Vol. 9, pp. 35-42.
  5. Degtyarev, V. G., Novikov, M. P., and Voropal, N. M., 1991, "Improving the Working Condition of the Electrode Wire-contact Tip Pair," Paton Welding Journal, Vol. 3, No 4, pp. 290-294.
  6. Quinn, T. P., Madigan, R. B., Mornis, M. A., and Siewert, T. A., 1995, "Contact Tube Wear Detection in Gas Metal Arc Welding," Welding Journal, Vol. 74, No. 4, pp. 115-121.
  7. DeNale, R., and Lukens, W. E., 1986, "Increasing Contact Tube Life during Titanium Gas Metal Arc Welding," Welding Journal, Vol. 65, pp. 28.
  8. Villafuerte, J., 1999, "Understanding Contact Tip Longevity for Gas Metal Arc Welding," Welding Journal, Vol. 78, No. 12, pp. 29-17.
  9. Villafuerte, J., 2000, "Improving Contact-tube Performance through Cryogenics," Welding Journal, Vol. 79, pp. 45.
  10. Massalski(ed.), T. B., 1986, "Binary Alloy Phase Diagram," ASM International, Vol. 1, pp. 819.

Cited by

  1. Evaluation of Gas Metal Arc Welding Characteristics according to Contact Tip Materials vol.32, pp.6, 2014, https://doi.org/10.5781/JWJ.2014.32.6.35