DOI QR코드

DOI QR Code

LED와 CMOS 이미지 센서 기반 간 기능 분석용 소형 광학장치

A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis

  • 김철 (고려대 공대 마이크로나노시스템) ;
  • 임창진 (고려대 공대 마이크로나노시스템) ;
  • 남명현 (고려대 의과대학 안암병원) ;
  • 김동식 (고려대 의과대학 안암병원) ;
  • 서성규 (고려대 공대 전자및정보공학과) ;
  • 박정호 (고려대 공대 전기전자전파공학과)
  • 투고 : 2012.01.19
  • 심사 : 2012.01.27
  • 발행 : 2012.02.01

초록

This paper presents a portable and compact optical device which can conveniently be used to perform a functional analysis of human liver function. The proposed system employed red/green LEDs, as a light source, and CMOS image sensor, which is commonly used in cellular phones. With this system, several blood serum samples have been evaluated for liver functional analysis by measuring light absorption level through the blood serum samples depending on aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin concentration. The light absorption through the blood serum samples containing AST, ALT, or total bilirubin can provide their concentrations. The green light absorption is more sensitive to the concentration of AST or ALT, and the red light absorption is more sensitive to the total bilirubuin concentration. Additional calibration steps were performed by using a MATLAB program in order to eliminate the light scattering effects from the extraneous particles existing in each blood serum sample. From the blind test, three standard light intensity curves through each enzyme have been obtained and the enzyme concentration values have been compared to those obtained from a commercially available biochemistry analyzer (Toshiba 200 FR). The average percent difference in the obtained concentrations from two systems for AST, ALT, and total bilirubin concentration came out to be 7.79%, 7.98%. and 7.56%, respectively, with the adjusted coefficient of determination (R2) higher than 0.98. This system can possibly lead to a low-cost and simple system that can be used as a point-of-care (POC) system in a condition without advanced equipments.

키워드

참고문헌

  1. 김일순, "한국인 5대 사망원인질환의 현황과 추이," 대한의학협회지, vol. 32(2), pp. 132-145, 1995.
  2. 전제윤, "알코올성 간질환," 대한의학협회지, vol. 36(6), pp. 719-724, 1993.
  3. 박정일, 정치경, 윤임중, 이승한, "건강한 성인 남자 사무직 근로자들에 있어서 알코올섭취와 몇 가지 간기능 검사들과의 관계," 대한산업의학지, vol. 1(1), pp. 127-139, 1989.
  4. O. Mudanyali, D. Tseng, C. Oh, S. O. Isikman, I. Sencan, W. Bishara, C. Oztoprak, S. Seo, B. Khademhosseini, and A. Ozcan, "Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications," Lab on a Chip, vol. 10, pp. 1417-1428, 2010. https://doi.org/10.1039/c000453g
  5. 연종은, "간기능 검사의 원리와 이해," 소화기연관학회 춘계학술대회, pp. 327-336, 2005.
  6. T. Su, S. Seo, A. Erlinger, D. Tseng, and A. Ozcan, "Towards Wireless Health: Lensless On-Chip Cytometry," Optics and Photonics News, vol. 19, pp. 24, 2008.
  7. S. Seo, T.-W. Su, A. Erlinger, and A. Ozcan, "Multi-color LUCAS: Lensfree On-chip Cytometry Using Tunable Monochromatic Illumination and Digital Noise Reduction " Cellular and Molecular Bioengineering, vol. 1, pp. 146-156, 2008. https://doi.org/10.1007/s12195-008-0018-6
  8. T. W. Su, S. Seo, A. Erlinger, and A. Ozcan, "High-throughput lensfree imaging and characterization of a heterogeneous cell solution on a chip," Biotechnology and bioengineering, vol. 102, pp. 856-868, 2009. https://doi.org/10.1002/bit.22116
  9. D.-S. Kim, J-H. Choi, M.-H. Nam, J.-W. Yang, J. J. Pak, and S. Seo, "LED and CMOS image sensor based hemoglobin concentration measurement," Sensors and Actuators B, vol. 157, pp. 103-109, 2011. https://doi.org/10.1016/j.snb.2011.03.032
  10. D. Tseng, O. Mudanyali, C. Oztoprak, S. O. Isikman, I. Sencan, O. Yaglidere, and A. Ozcan, "Lensfree microscopy on a cellphone," Lab on a Chip, vol. 10, pp. 1787-1792, 2010. https://doi.org/10.1039/c003477k
  11. A. Ozcan, "Smart technology for global access to healthcare," SPIE newsroom, vol. 2, p. 1-2, 2010.
  12. M. Kaplan, "SEvaluation of hepatobillary diseases," Internal Medicine, edited by J. H. Stein, Boston, Little Brown, p.554, 1990.
  13. Bioclinical system,"AST, ALT, total bilirubin 측정 매뉴얼", Available at http://www.cyberbcs.co.kr
  14. HARVATEK, Available: http://www.harvatek-intl.com.
  15. S. Reitman and S. Frankel, "A colorimetric method for the determination of serum glutamic oxalacetic and glutamic pyruvic transaminases," American journal of clinical pathology, vol. 28, p. 56, 1957. https://doi.org/10.1093/ajcp/28.1.56
  16. R. Thompson, "Modification of Michaelsson's method for the measurement of plasma total bilirubin," Journal of Clinical Pathology, vol. 22, p. 439-441, 1969. https://doi.org/10.1136/jcp.22.4.439
  17. D. S. Kim, J. H. Choi, M. H. Nam, J. W. Yang, J. J. Pak, and S. Seo, "LED and CMOS image sensor based hemoglobin concentration measurement technique," Sensors and Actuators B: Chemical, vol. 157, pp. 103-109,2011. https://doi.org/10.1016/j.snb.2011.03.032
  18. S. R. C. J.D.J. Ingle, Spectrochemical Analysis, Prentice Hall, 1988.