Abstract
Due to the concept of "full-strength capacity connection," the pushover analysis method became an issue in designing steel connections. It is difficult to apply practically, however, because engineers are unfamiliar with such method. Moreover, there have been insufficient representative studies on them because most of the past pertinent studies were performed based on high-rise and/or virtual structures. As such, for this study, an actual(now in process) steel structure, a medium-low-rise industrial building, was selected. To perform pushover analysis, it was suggested that lateral load patterns be used in a simple and clear manner for three- and two-dimensional analysis models. A new hinge property was also suggested to prevent erroneous connection design results that can occur in the design process. The suggested load patterns showed almost the same results regardless of the model that was used, from which the obtained load patterns were different. This result implies the validity of the suggested load patterns. As for the suggested hinge property, the structural analysis yielded sound and reasonable results, which confirmed the validity of the proposed hinge property.
강구조 접합부 설계에 '전강도 접합' 개념이 도입됨에 따라 비선형 정적 해석의 결과를 이용한 설계가 주목을 받고 있다. 그러나 현재 실무에 적용하기에는 생소한 개념이어서 어려움이 있다. 또한 대부분의 기존 연구가 가상의 고층 구조물에 대한 내용 이어서 실제 대다수 설계가 이루어지는 중 저층 산업용 구조물에 대한 연구는 부족하다. 이에 본 연구에서는 실제 진행 중인 중 저층 산업용 구조물의 비선형 정적 해석을 위한 간단 명료한 하중 패턴을 3차원 해석 모델에 대해 제시하여 해석을 수행하였고, 실무에서의 유용성을 위해 2차원 해석 모델에 대한 보다 간단한 하중 패턴을 제시하였다. 또한 해석 결과를 이용하여 접합부를 설계하는 과정에서 나타날 수 있는 문제점에 대해 비선형 정적 해석에 사용하는 힌지 특성을 간단한 유추를 통해 새롭게 제시하였다. 제시된 하중 패턴은 서로 다른 방법으로 구하였으나 동일한 결과를 보여 상호 신뢰성을 입증하였으며, 제시된 힌지 특성을 적용한 구조물의 해석 결과로부터 합리적인 결과를 얻어 그 타당성을 검증하였다.