Abstract
This paper presents the characteristics behavior of dike structure and foundation ground through the shaking table model test. The vibration loadings of design earthquake acceleration of 0.154g was applied to this laboratory model test regarding on dike structure and foundation ground under the structure. The model was formulated with 1/100 design of representative cross section for evaluating the effectiveness of vibration. Based on the test results, we can analysis the behavior of lateral displacement and settlement characteristics of structure under the earthquake loading. The pore water pressure was also monitored in the upper, middle and lower layers of ground. Finally, the actual displacements and pore water pressure of the structure can be predicted by using the results of the laboratory shaking table test.
본 연구에서는 방수제 구조물 및 하부지반에 대하여 1/100 축소모형의 비율을 갖는 토조를 제작, 설계지진 가속도 0.154g의 진동하중 적용시 진동대 모형실험을 통하여 구조물의 거동특성과 내진 안정성을 평가하였다. 실제 시공순서를 재현하여 완성 후 진동대 모형토조 하부에 설정된 지진하중을 발생시켜 지진에 의한 하부지반과 방수제 구조물의 상호작용을 분석하였다. 즉, 구조물의 수평 및 수직 변위, 구조물 하부지반에 작용하는 간극수압 변화, 하부지반 및 방수제 구조물의 최대가속도 변화량 측정 등 계측결과를 비교 분석하여 내진 안정성을 판단하였다.