DOI QR코드

DOI QR Code

Analysis on Air Quality Characteristics through Air Quality Monitoring Stations in urban Background and High Altitude in 2005~2006 in Seoul

서울시의 2005~2006년 도시배경 및 상층측정망의 대기질 특성 분석

  • Yoo, Seung-Sung (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Jeon, Jae-Sik (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Jung, Kweon (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Shin, Eun-Sang (Department of Environment Health, Dongnam Health College) ;
  • Jung, Bu-Jeon (Department of Advanced Technology Fusion, Konkuk University) ;
  • Ryu, Ri-Na (Department of Advanced Technology Fusion, Konkuk University) ;
  • Woo, Jung-Hun (Department of Advanced Technology Fusion, Konkuk University) ;
  • Sunwoo, Young (Department of Advanced Technology Fusion, Konkuk University)
  • 유승성 (서울시보건환경연구원 대기부) ;
  • 전재식 (서울시보건환경연구원 대기부) ;
  • 정권 (서울시보건환경연구원 대기부) ;
  • 신은상 (동남보건대학 환경보건과) ;
  • 정부전 (건국대학교 신기술융합학과) ;
  • 류리나 (건국대학교 신기술융합학과) ;
  • 우정헌 (건국대학교 신기술융합학과) ;
  • 선우영 (건국대학교 신기술융합학과)
  • Received : 2010.08.20
  • Accepted : 2011.02.11
  • Published : 2011.02.28

Abstract

The results of comparing $PM_{10}$ concentration between 'Namsan' and 'Yongsan-gu' air quality monitoring stations show similar values with averaged concentration in the whole Seoul. The correlation factors in both sites were 0.865, 0.828 in 2005, 2006, respectively. For 'Bukhansan' and 'Gangbuk-gu' air quality monitoring stations, different from the results mentioned above, they showed clear differences as altitude changes. PM10 concentration in 'Bukhansan' monitoring stations was 10 ${\mu}g/m^3$ lower than 'Gangbuk-gu' monitoring station which is located near the ground. Also, averaged PM10 concentration in 'Bukhansan' and 'Gangbuk-gu' monitoring stations was lower than that in the whole Seoul. When comparing $NO_2$ concentration between 'Namsan' and 'Yongsan-gu' monitoring stations, $NO_2$ concentration in 'Namsan' monitoring station was lower than 'Yongsan-gu' monitoring station. For $NO_2$ concentration in 'Bukhansan', 'Gangbuk-gu' and 'the whole Seoul', there were the same pattern in 'Gangbuk-gu' and the 'the whole Seoul' and low values in 'Bukhansan' monitoring station. The correlation factors of $NO_2$ concentration in 'Bukhansan' and 'Gangbukgu' was 0.525, 0.549 in 2005, 2006, respectively, which stands for low correlationship.

Keywords

References

  1. 김신도, 2004, 우리나라 미세먼지 현황 및 문제점, 한국대기환경학회 추계학술대회 논문집.
  2. 김용표, 2006, 서울의 미세먼지에 의한 대기오염, 한국대기환경학회지, 22(5), 535-553.
  3. 김운수, 2004, 서울시 미세먼지 배출량 조사.분석 및 관리방안 연구, 서울시정개발연구원.
  4. 김철희, 박일수, 이석조, 김정수, 진형아, 성한규, 2004, 지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향, 한국대기환경학회 지, 20(2), 215-224.
  5. 박광석, 2006, 수도권 대기환경관리 기본계획, 한국대기환경학회 2006 춘계학술대회논문집, pp. 37-42.
  6. 박일수, 이석조, 김종춘, 김상균, 이동원, 유 철, 이재범, 송형도, 이정영, 김지현, 2005, 수도권지역에서 오염원별 대기오염농도 기여도 평가, 한국대기환경학회지, 21(5), 495-505.
  7. 서울특별시, 2006, 수도권 대기환경개선 기본계획 추진을 위한 서울특별시 시행계획, 서울특별시.
  8. 유은철, 박옥현, 2006, 부산지역의 다양한 환경적 요인의 변화에 따른 대기오염 측정망평가, 한국대기환경학 회지, 22(4), 405-420.
  9. 조경두, 2001, 지역대기질의 체감오염도 개선을 위한 시책 연구, 인천발전연구원.
  10. 환경부, 2004, 측정망 설치.운영 실태평가 및 기본계획 조정을 위한 연구.
  11. 환경부, 2005, 수도권 대기환경관리 기본계획, 환경부.
  12. 환경부, 2006, 대기오염측정망 설치.운영 지침.
  13. H. Choi, Y. H. Zhang, and K. H. Kim, 2008, Sudden high concentration of TSP affected by atmospheric boundary layer in Seoul metropolitan area during dust storm period, Environment International, (In press).
  14. Larsen, R. I., 1973, An air quality data analysis system for interrelating effects, standards and need source reductions, Journal of Air Pollutants and Control Assessment, 23, 933-940. https://doi.org/10.1080/00022470.1973.10469861