DOI QR코드

DOI QR Code

Prediction of Energy Expenditure by Using a Tri-axial Accelerometer

단일 3축 가속도센서를 사용한 보행 시 대사에너지 예측

  • Lee, Hee-Young (Department of Biomedical Engineering & Institute of Medical Engineering, Graduate School of Yonsei University) ;
  • Kim, Seung-Hyeon (Department of Biomedical Engineering & Institute of Medical Engineering, Graduate School of Yonsei University) ;
  • Lee, Dong-Yeop (Department of Biomedical Engineering & Institute of Medical Engineering, Graduate School of Yonsei University) ;
  • Park, Sun-Woo (Department of Biomedical Engineering & Institute of Medical Engineering, Graduate School of Yonsei University) ;
  • Kim, Young-Ho (Department of Biomedical Engineering & Institute of Medical Engineering, College of Health Sciences, Yonsei University)
  • 이희영 (연세대학교 대학원 의공학과, 연세의료공학연구원) ;
  • 김승현 (연세대학교 대학원 의공학과, 연세의료공학연구원) ;
  • 이동엽 (연세대학교 대학원 의공학과, 연세의료공학연구원) ;
  • 박선우 (연세대학교 대학원 의공학과, 연세의료공학연구원) ;
  • 김영호 (연세대학교 보건과학대학 의공학과, 연세의료공학연구원)
  • Received : 2011.02.15
  • Accepted : 2011.06.21
  • Published : 2011.06.30

Abstract

The purpose of this study was to compare metabolic energy expenditure with the computed kinetic energy for different speeds of walking and running over the treadmill and to find the relevance for individual and group equation by performing a statistical analysis, Bland-Altman plot. Seven male subjects participated, and they were required to walk and run on the treadmill with the gas analyzer and triaxial accelerometer. Walking speeds were 3.0, 4.0, 5.0 and 6.0 km/h and running speeds were 7.0, 8.0 and 9.0 km/h respectively. Kinetic energy was calculated by the integration of acceleration data and compared with the metabolic energy measured by a gas analyzer. Correlation coefficients showed relatively good between the measured metabolic energy and the calculated kinetic energy. In addition, a dramatic increase in kinetic energy was also observed at the transition speed of walking and running, and two standard deviations in Bland-Altman plot, derived from the difference between measured and predicted values, were 1.14, 2.53, 2.93, 1.80, 2.80, 0.60 and 2.48 respectively. It was showed that there is no difference for methods of how to predict the kinetic energy expenditure for individual and group even though people had each different physical characteristic.

Keywords

References

  1. Anderssen, S. A., & Hjermann, I.(2000). Physical activity - a crucial factor in the prevention of cardiovascular diseases. Tidsskr Nor Laegeforen, 120(26), 3168-3172.
  2. Bland, J. M., & Altman, D. G.(1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lamcet, 1(8476), 307-310.
  3. Chen, K. Y., & Sun, M.(1997). Improving energy expenditure estimation by using a triaxial accelerometer. Journal of Applied Physiology, 83, 2112-2122.
  4. Choi, J. H., Lee, J., Hwang, H. T., Kim, J. P., Park, J. C., & Shin, K.(2005). Estimation of Activity Energy Expenditure: Accelerometer Approach. 27th Annual International Conference of the IEEE. Shanghai, China.
  5. Crouter, S. E., Clowers, K. G., & Bassett, D. R.(2006). A novel method for using accelerometer data to predict energy expenditure. Journal of Applied Physiology, 100, 1324-1331.
  6. Kang, D. W., Choi, J. S., Mun, K. R., Tack, G. R.(2008). Estimation of energy expenditure of walking and running based on triaxial accelerometer and physical information. Korean Journal of Sport Biomechanics, 18(4), 109-114. https://doi.org/10.5103/KJSB.2008.18.4.109
  7. Kang, D. W., Choi, J. S., Mun, K. R., Bang Y. H., Tack, G. R.(2009). A study on the estimation accuracy of energy expediture by different attaching position of accelerometer. Korean Journal of Sport Biomechanics, 19(1), 179-186. https://doi.org/10.5103/KJSB.2009.19.1.179
  8. Kim, H. J., Park, J. H., Kang, S. J.(2006). Comparison Between Movement Accelerometers and Activity Log by Record for Free-Living Physical Activity. Korean Society for Measurement and Evaluation in Physical Education and Sports Science, 8(1), 67-80.
  9. Leenders, N. Y., Nelson, T. E., Sherman, W. M.(2002). Ability of different physical activity monitors to detect movement during treadmill walking. International Journal of Sports Medicine, 24, 43-50.
  10. Marco Traballesi, Paolo Porcacchia, Tiziano Averna, Stefano Brunelli.(2008). Energy cost of walking measurements in subjects with lower lomb amputations : A comparison study between floor and treadmill test. Gait & Posture, 26, 70-75.
  11. Meiner, D. R., Pugh L. G.(1968). The relationship of oxygen intake and velocity of walking and running in competition walkers. Journal of Physiology, 197, 717-721. https://doi.org/10.1113/jphysiol.1968.sp008584
  12. National Health Insurance Corporation(2008), Research about obesity index
  13. Nilsson, A., Brage, S., Anderssen, S. A., Sardinha, L. B., Wedderkopp, N., Anderssen, L. B., & Ekelund, U.(2008). Comparison of equations for predicting energy expenditure from accelerometer counts in children. Scandinavian Journal of Medicine in Sports, 18, 643-650. https://doi.org/10.1111/j.1600-0838.2007.00694.x
  14. Song, Y. M., Ku, H. J., Lee, M. C., Lee, S. B.(2005). Methods of Estimation of Physical Activity and Energy Expenditure. Journal of Coaching Development, 7(3), 159-168.