DOI QR코드

DOI QR Code

Generalized load cycles for dynamic wind uplift evaluation of rigid membrane roofing systems

  • Baskaran, A. (National Research Council of Canada) ;
  • Murty, B. (Department of Civil Engineering, University of Ottawa) ;
  • Tanaka, H. (Department of Civil Engineering, University of Ottawa)
  • Received : 2010.03.09
  • Accepted : 2011.01.11
  • Published : 2011.09.25

Abstract

Roof is an integral part of building envelope. It protects occupants from environmental forces such as wind, rain, snow and others. Among those environmental forces, wind is a major factor that can cause structural roof damages. Roof due to wind actions can exhibit either flexible or rigid system responses. At present, a dynamic test procedure available is CSA A123.21-04 for the wind uplift resistance evaluation of flexible membrane-roofing systems and there is no dynamic test procedure available in North America for wind uplift resistance evaluation of rigid membrane-roofing system. In order to incorporate rigid membrane-roofing systems into the CSA A123.21-04 testing procedure, this paper presents the development of a load cycle. For this process, the present study compared the wind performance of rigid systems with the flexible systems. Analysis of the pressure time histories data using probability distribution function and power spectral density verified that these two roofs types exhibit different system responses under wind forces. Rain flow counting method was applied on the wind tunnel time histories data. Calculated wind load cycles were compared with the existing load cycle of CSA A123.21-04. With the input from the roof manufacturers and roofing associations, the developed load cycles had been generalized and extended to evaluate the ultimate wind uplift resistance capacity of rigid roofs. This new knowledge is integrated into the new edition of CSA A123.21-10 so that the standard can be used to evaluate wind uplift resistance capacity of membrane roofing systems.

Keywords

References

  1. Amzallag, C., Gerey, J.P., Robert, J.L. and Bahuaudl, J. (1994), "Standardization of the rain flow counting method for fatigue analysis", Int. J. Fatigue, 16(4), 287-293. https://doi.org/10.1016/0142-1123(94)90343-3
  2. ASTM E1049 (2005), "Standard practices for cycle counting in fatigue analysis", ASTM International Conshohocken, PA.
  3. ASCE 7 (2010), "Minimum design loads for buildings and other structures", American Society of Civil Engineer (ASCE), Reston, VA.
  4. Baskaran, A. (1986), Wind load on flat roofs with parapet , MEng. thesis, (Building), Centre for Building Studies, Concordia University, Montreal,QC.
  5. Baskaran, A, Savage, M.G., Alfawakhiri, F and Cooper, K (1996), Pressure distribution data measured during the october 1995 wind tunnel tests on a mechanically attached EPDM single ply roofing systems, Internal Report LTR A004, Institute for Aerospace Research (IAR), NRCC, 1-203, Ottawa, ON, Canada.
  6. Baskaran, A., Chen, Y and Savage, M (1997), "Development of a wind load cycle for testing commercial building envelopes", Proceedings of the Struct. Congress XV, ASCE, Portland, Oregon.
  7. Baskaran, A., Chen, Y. and Vilaipornsawai, A (1999), "A new dynamic wind load cycle to evaluate flexible membrane roofs", J. Test. Eval., 27(4), 249-265. https://doi.org/10.1520/JTE12223J
  8. Banks, D., Meroney, R.N., Sarkar P.P., Zhao and Z., Wu, F. (2000), "Flow visualization of conical vortices on flat roofs with simultaneous surface pressure measurement" , J. Wind Eng. Ind. Aerod., 84(1), 65-85. https://doi.org/10.1016/S0167-6105(99)00044-6
  9. CSA A123.21-04. (2004), Standard test method for the dynamic wind uplift resistance of mechanically attached membrane-roofing systems, Canadian Standards Association (CSA), Toronto, ON.
  10. Chen, Y. and Baskaran, B.A. (1997), Development of load sequence using pressure records measured from Wind tunnel studies for mechanically attached single-ply PVC and EPDM roofs , Internal report No. IR743, Institute for Research in Construction, NRCC, Ottawa, ON.
  11. Compaq Visual FORTRAN Version 6.6 (2001), Compaq Computer Corporation.
  12. Downing, S.D. and Socie, D.F (1982), "Simple rainflow counting algorithms", Int. J. Fatigue, 4(1), 31-40. https://doi.org/10.1016/0142-1123(82)90018-4
  13. Glinka, G. and Kam, J.C.P. (1987), "Rainflow counting algorithm for very long stress histories", Int. J. Fatigue, 9(4), 223-228. https://doi.org/10.1016/0142-1123(87)90025-9
  14. Jancauskas, E.D.J., Mahendran, M. and Walker, G.R., (1994), "Computer simulation of the fatigue behavior of roof cladding during the passage of a tropical cyclone", J. Wind Eng. Ind. Aerod., 51(2), 215-227. https://doi.org/10.1016/0167-6105(94)90005-1
  15. Lawson, T.V. (1980), "Wind effect on buildings", J. Appl. Sci., 1, 1-318.
  16. Laaly H.O. (1992), "The science and technology of traditional and modern roofing systems", Laaly Scientific Publisher, 9037, Monte Mar Drive, Los Angeles, CA. , 90035-4235.
  17. Mathwork inc (2004), "Matlab, the language of technical computing", version 7.0.1., Math Software Co., USA.
  18. Murty, B. (2010), Wind uplift performance evaluation of adhesive applied roofing systems, Ph.D. Thesis, Department of Civil Engineering, University of Ottawa, Ottawa, Canada, 2009 (in press).
  19. National Research Council Canada (2010), National building code of canada user's guide-structural commentaries, NRCC, Ottawa, Canada
  20. Rychlik, I (1987), "A new definition of the rain flow cycle counting method", Int. J. Fatigue, 9(2), 119-121. https://doi.org/10.1016/0142-1123(87)90054-5
  21. Savage, M.G., Baskaran, A., Cooper, K.R and Lei, W. (1996), Pressure distribution data measured during the November 1994 wind tunnel tests on a mechanically attached, PVC single-ply roofing system , IAR Report LTR-A-003, NRCC, Ottawa,ON.
  22. Simiu, E and Scanlan, R.H (1986), Wind Effects on Structures: An introduction to wind engineering, John Willey & Sons, NY.
  23. Stathopoulos, T., Marathe, R. and Wu, H (1999), "Mean wind pressures on flat roof corners affected by parapets:field and wind tunnel studies", Eng. Struct., 21(7), 629-638. https://doi.org/10.1016/S0141-0296(98)00011-X
  24. Stathopoulos, T (2008), Pressure time histories from rigid wind tunnel models, Technical Report, Centre for Building Studies, Concordia University. Montreal, QC.
  25. Smith, T.L (2009), "Wind safety of the building envelope, whole building design guide (WBDG)", National Institute of Building Science, Washington, DC.
  26. Uematsu, Y., Watanabe, K., Sasaki, A., Yamada, M. and Hongo, T. (1999), "Wind-induced dynamic response and resultant load estimation of a circular flat roof, closed-type wind tunnel at Kajima Technical Research Institute", J. Wind Eng. Ind. Aerod., 83(1-3), 251-261. https://doi.org/10.1016/S0167-6105(99)00076-8
  27. Xu, Y.L., Mehta, K.C. and Reardon, G.F (1995), "Fatigue of metal roof cladding subject to wind loading, part i: fatigue-related characteristics of roof pressures", Proceedings of the 9th ICWE, New Delhi. India.

Cited by

  1. Numerical Analysis of Wind-Induced Response of a Wrinkled Membrane vol.20, pp.5, 2011, https://doi.org/10.1142/s021945542050056x