원자력 발전소 RCB 내 중요배관의 KEPIC 코드에 의한 내진 안전성 설계

A Seismic Stability Design by the KEPIC Code of Main Pipe in Reactor Containment Building of a Nuclear Power Plant

  • 이형복 (안동과학대학 자동차에너지계열) ;
  • 이진규 ((주)삼의공영, 플랜트 설계부) ;
  • 강태인 ((주)삼의공영, 플랜트 설계부)
  • Yi, Hyeong-Bok (Section of Automobile & Energy, Andong Science College) ;
  • Lee, Jin-Kyu (Dept. of Plant Engineering, SAMY Industrial Co., LTD.) ;
  • Kang, Tae-In (Dept. of Plant Engineering, SAMY Industrial Co., LTD.)
  • 투고 : 2010.10.12
  • 심사 : 2011.01.06
  • 발행 : 2011.02.01

초록

In piping design of nuclear power plant facilities, the load stress according to self-weight is important for design values in test run(shutdown and starting). But sometimes it needs more studies, such as seismic analysis of an earthquake of power plant area and fatigue life and stress of thermal expansion and anchor displacement in operating run. In this paper, seismic evaluations were performed to nuclear piping system of Shin-Kori NO. 3&4 being built in Pusan lately. Results of seismic analysis are evaluated on basis of KEPIC MN code. The structural integrity on RCB piping system was proved.

키워드

참고문헌

  1. Chopra, A. K., "Dynamic of structures, theory and application to earthquake," Prentice Hall, 1995.
  2. ASCE Standard 4-98, "Seismic analysis of safetyrelated nuclear structure and commentary on standard for seismic analysis of safe-related nuclear structures," 1986.
  3. Kim, Y. W., Bae, Y. C. and Lee, Y. S., "Countermeasure on high vibration of branch pipe with pressure pulsation transmitted from main steam header," Trans. of the Korean Society for Noise Vibration Engineering, Vol. 15, No. 8, pp. 988 - 995, 2005. https://doi.org/10.5050/KSNVN.2005.15.8.988
  4. Jhung, M. J. and Choi, Y. H., "Surge line stress due to thermal stratification," Nuclear Engineering and Technology, Vol. 40, No. 3, pp. 239 - 250, 2008. https://doi.org/10.5516/NET.2008.40.3.239
  5. Huh, N. S., Lee, C. H., Kim, Y. J., Seok, C. S. and Pyo, C. R., "Development of a simplified design method for LBB application to nuclear piping," Journal of KIIS , Vol. 14, No. 2, pp. 32-41, 1999.
  6. Yu, Y. J. and Kim, Y. J., "Effect of nozzle on LBB evaluation for small diameter nuclear piping," Trans. of KSME A, Vol. 20, No. 6, pp. 1872-1881 ,1996.
  7. Yun, S. C., Kim, I. Y. and Hwang, I. K., "A review of OBE elimination on evaluation of the code pipe stress and postulation of pipe brake locations," Transmitted of the 17th International Journal Conference on Structural Mechanics in Reactor Technology (SMiRT), Paper No. K 15-5, 2003.
  8. KEPIC 1995 Edition.
  9. KEPIC 2000 Edition.
  10. U.S. Nuclear Regulatory Commission, "Combining Modal Responses and Spatial Components in Seismic Response Analysis," Regulatory Guide 1.92, 1992.
  11. U.S. Nuclear Regulatory Commission, "Quality Group Classifications and Standards for Water, Steam, and Radioactive Waste Containing Components of Nuclear Power Plants," Regulatory Guide 1.26, Revision 3, 1976.
  12. U.S. Nuclear Regulatory Commission, "Seismic Design Classification," Regulatory Guide 1.29, 1992.
  13. U.S. Nuclear Regulatory Commission, "Design Limits and Loading Combinations for Seismic Category I Fluid System Components," Regulatory Guide 1.48, 1973.
  14. KEPCO E&C, "Lesson Plan for Training Personnel in Piping Analysis," 2003.
  15. Sargent & Lundy, "User's Manual Integrated Piping Analysis System, PIPSYS," EMD-TP-1, Volume I, 2001.