DOI QR코드

DOI QR Code

Counterfeit Detection Using Characterization of Safety Feature on Banknote with Full-field Optical Coherence Tomography

  • Choi, Woo-June (School of Information and Communications, Gwangju Institute of Science and Technology (GIST)) ;
  • Min, Gi-Hyeon (School of Information and Communications, Gwangju Institute of Science and Technology (GIST)) ;
  • Lee, Byeong-Ha (School of Information and Communications, Gwangju Institute of Science and Technology (GIST)) ;
  • Eom, Jong-Hyun (Graduate-program of Medical System Engineering, Gwangju Institute of Science and Technology (GIST)) ;
  • Kim, Ju-Wan (Graduate-program of Medical System Engineering, Gwangju Institute of Science and Technology (GIST))
  • 투고 : 2010.10.20
  • 심사 : 2010.11.15
  • 발행 : 2010.12.25

초록

We report an application of full-field optical coherence tomography (FF-OCT) for identifying counterfeit bank notes. The depth-resolved imaging capability of FF-OCT was used for tomographic identification of superficially-identical objects. By retrieving the internal structures of the security feature (cash hologram) of an original banknote, we could demonstrate the feasibility of FF-OCT to identify counterfeit money. The FF-OCT images showed that the hologram consisted of micron scale multi-coated layers including an air gap. Therefore, it is expected that FF-OCT has potential as a new non-invasive tool to discern imitation of currency, and it would find applications in a wide field of counterfeit sciences.

키워드

참고문헌

  1. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and J. G. Fujimoto, “Optical coherence tomography,” Science 254, 1178-1181 (1991). https://doi.org/10.1126/science.1957169
  2. S. A. Boppart, B. E. Bouma, C. Pitris, J. F. Southern, M. E. Brezinski, and J. G. Fujimoto, “In vivo cellular optical coherence tomography imaging,” Nat. Med. 4, 861-865 (1998). https://doi.org/10.1038/nm0798-861
  3. A. M. Zysk, F. T. Nguyen, A. L. Oldenburg, D. L. Marks, and S. A. Boppart, “Optical coherence tomography: a review of clinical development from bench to bedside,” J. Biomed. Opt. 12, 051403 (2007). https://doi.org/10.1117/1.2793736
  4. A. Dubois, K. Grieve, G. Moneron, R. Lecaque, L. Vabre, and C. Boccara, “Ultrahigh-resolution full-field optical coherence tomography,” Appl. Opt. 43, 2874-2883 (2004). https://doi.org/10.1364/AO.43.002874
  5. M. Akiba, N. Maeda, K. Yumikake, T. Soma, and K. Nishida, “Ultrahigh-resolution imaging of human donor cornea using full-field optical coherence tomography,” J. Biomed. Opt. 12, 041202 (2007). https://doi.org/10.1117/1.2764461
  6. E. S. Choi, W. J. Choi, S. Y. Ryu, B. H. Lee, J.-H. Lee, H.-S. Bom, and B. I. Lee, “Feasibility of full-field optical coherence microscopy in ultra-structural imaging of human colon tissues,” J. Korean Phys. Soc. 57, 79-83 (2010). https://doi.org/10.3938/jkps.57.79
  7. W. J. Choi, D. I. Jeon, S.-G. Ahn, J.-H. Yoon, S. Kim, and B. H. Lee, “Full-field optical coherence microscopy for identifying live cancer cells by quantitative measurement of refractive index distribution,” Opt. Express 18, 23285-23295 (2010). https://doi.org/10.1364/OE.18.023285
  8. L. Vabre, V. Loriette, A. Dubois, J. Moreau, and A. C. Boccara, “Imagery of local defects in multilayer components by short coherence length interferometry,” Opt. Lett. 27, 1899-1901 (2002). https://doi.org/10.1364/OL.27.001899
  9. D. S. Mehta, T. Anna, and C. Shakher, “Scientific and engineering applications of full-field swept-source optical coherence tomography,” J. Opt. Soc. Korea 13, 341-348 (2009). https://doi.org/10.3807/JOSK.2009.13.3.341
  10. The Use and Counterfeiting of United States Currency Abroad, Part 3, United States Treasury Department (2006).
  11. http://www.eubusiness.com/news-eu/ecb-bank-money.27a/
  12. W. J. Choi, J. Na, S. Y. Ryu, and B. H. Lee, “Realization of 3-D topographic and tomographic images with ultrahighresolution full-field optical coherence tomography,” J. Opt. Soc. Korea 11, 18-25 (2007). https://doi.org/10.3807/JOSK.2007.11.1.018
  13. A. Dubois, “Phase-map measurements by interferometry with sinusoidal phase modulation and four integrating buckets,” Appl. Opt. 18, 1972-1979 (2001).

피인용 문헌

  1. Characterization of wet pad surface in chemical mechanical polishing (CMP) process with full-field optical coherence tomography (FF-OCT) vol.19, pp.14, 2011, https://doi.org/10.1364/OE.19.013343
  2. Using the fibre structure of paper to determine authenticity of the documents: Analysis of transmitted light images of stamps and banknotes vol.244, 2014, https://doi.org/10.1016/j.forsciint.2014.09.002
  3. Optical identification based on time domain optical coherence tomography vol.54, pp.25, 2015, https://doi.org/10.1364/AO.54.007514
  4. Quantitative assessment of touch-screen panel by nondestructive inspection with three-dimensional real-time display optical coherence tomography vol.68, 2015, https://doi.org/10.1016/j.optlaseng.2014.12.013
  5. Characterization of automotive paint by optical coherence tomography vol.266, 2016, https://doi.org/10.1016/j.forsciint.2016.06.007
  6. Fast Industrial Inspection of Optical Thin Film Using Optical Coherence Tomography vol.16, pp.12, 2016, https://doi.org/10.3390/s16101598
  7. Non-Destructive Inspection Methods for LEDs Using Real-Time Displaying Optical Coherence Tomography vol.12, pp.12, 2012, https://doi.org/10.3390/s120810395