Abstract
Angular Deviation(AD) on transparency applied to TA-50 Aircraft deteriorates armament system's accuracy because it makes a difference in between actual and theoretical targets. In order to increase accuracy, therefore, TA-50 Aircraft measures AD on transparency and provide the measured values for the integrated mission display computer as a type of AD coefficients. This makes AD revised so that pilots can accurately see the actual target on their head-up display. In order to implement such mechanism into a real field, we develop a new device and system automatically measuring AD for the first time. We also deal with basic concept including AD induction formula as well as operating systems. As a consequence of testing the accuracy and precision for verifying reliability of the system, we got satisfactory results. In specific, the accuracy was within the resultant criterion of 1%. The precision was also satisfied with respect to the whole criteria. The system developed through this research is qualified as a military standard equipment for transparency of the canopy.
TA-50 항공기에 적용되는 투명체의 편각은 실제목표와 투명체를 통해 조종사가 인식하는 목표와 차이를 유발시켜, 부정확한 조준 및 이로 인한 무장계통의 정확도를 저하시킨다. 이러한 문제를 해결하기 위해 TA-50 항공기에서는 원드실드 투명체의 편각을 실측하여 편각 계수 형태로 항공기의 통합임무시현컴퓨터에 입력, 각도 편차를 보정하여 전방상향 시현기에서 목표물에 정확히 조준되도록 한다. 이러한 작동원리를 실전에 적용하기 위해 본 연구에서는 편각 자동측정장비를 국내 최초 독자적으로 개발하였다. 또한 편각 유도공식 산출 등 개발개념 및 운영 체계와 장비의 신뢰성 검증을 위한 정확성 및 정밀성에 대한 내용을 다룬다. 본 연구를 통해 개발한 장비의 정확성은 최종 판정기준인 1% 미만으로 매우 적합하였으며, 정밀성 또한 최종 판정기준을 모두 만족하여 매우 적합하다는 결과를 얻었다. 본 연구를 통해 개발된 편각 자동측정장비는 우수한 품질로 입증되어 캐노피 투명체의 국방규격에 등재되어 사용되고 있다.