참고문헌
- Adell R, Lekholm U, Rockler B. A 15-year study of osseo-integrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416. https://doi.org/10.1016/S0300-9785(81)80077-4
- Phillips KM, Nicholls JI, Ma T et al. The accuracy of three implant impression technique. A three dimensional analysis. Int J Oral Maxillofac Implants 1994;9:533-40.
- Naconecy MM, Teixeira ER Shikai RS. Evaluation of the accuracy of 3 transfer techniques for implantsupported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19:192-8.
- Tolman DE, Laney WR. Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 1992;7:477-84.
- Jemt T, Rubenstein JE, Carlsson L et al. Measuring fit at the implant prosthodontic interface. J Prosthet Dent 1996;75:314-25. https://doi.org/10.1016/S0022-3913(96)90491-6
- Becker W, Becker BE, Newman MG et al. Clinical and microbiologic findings that may contribute to dental implant failure. Int J Oral Maxillofac Implants 1990;5:31-8.
- Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-8. https://doi.org/10.1016/0022-3913(83)90361-X
- Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-5. https://doi.org/10.1016/0022-3913(89)90084-X
- Assif D, Marshak B, Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996;11:216-22.
- Carr AB. A Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-55.
- Barrett MG, de Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993;2:75-82. https://doi.org/10.1111/j.1532-849X.1993.tb00387.x
- Assif D, Fenton A, Zarb G. Comparative accuracy of implant impression procedures. Int J Periodontics & Restorative Dentistry 1992;12:112-121.
- HeeJe L, Joseph SS, Hochstedler JL. The accuracy of implant impressions: A systematic review. J Prosthet Dent 2008;100:285-91. https://doi.org/10.1016/S0022-3913(08)60208-5
- Burton JF, Hood JA, Plunkett DJ et al. The effects of disposable and custom-made impression trays on the accuracy of impressions. J Dent 1989;17:121-3. https://doi.org/10.1016/0300-5712(89)90104-8
- Bomberg TJ, Hatch RA, Hoffman W. Impression material thickness in stock and custom tray. J Prosthet Dent 1985;54:170-2. https://doi.org/10.1016/0022-3913(85)90278-1
- Burns J, Palmer R, Howe L et al. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 2003;89:250-5. https://doi.org/10.1067/mpr.2003.38
- Reisbick MH, Matyas J. The accuracy of highly filled elastomeric impression materials. J Prosthet Dent 1975;33:67-72. https://doi.org/10.1016/S0022-3913(75)80148-X
- Cho GC, Chee WW. Distortion of disposable plastic stock trays when used with putty vinyl polysiloxane impression materials. J Prosthet Dent 2004;92:354-8. https://doi.org/10.1016/j.prosdent.2004.07.020
- Brunski JB, Hipp JA. In vivo forces on endosteal implants: a measurement system and biomechanical considerations. J Prosthet Dent 1984;51:82-90. https://doi.org/10.1016/S0022-3913(84)80112-2
- Boggan RS, Strong JT, Misch CE et al. Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants. J Prosthet Dent 1999;82:436-40. https://doi.org/10.1016/S0022-3913(99)70030-2
- White GE. Osseointegrated dental technology. London: Quintessence, 1993:82-3.
- Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-60.
- Binon PP, McHugh MJ. The effect of eliminating implant/abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-9.
- Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-7. https://doi.org/10.1016/0022-3913(90)90235-5
- Branemark PI, Albrektsson T, Zarb GA. Tissueintegrated prostheses: Osseointegration in clinical dentistry. Chicago: Quintessence; 1985. p.253-7.
- Iturregui JA, Aquilino SA, Ryther JS. Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 1993;69:503-9. https://doi.org/10.1016/0022-3913(93)90160-P
- Vigolo P, Fonzi F, Majzoub Z et al. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 2004;92:470-6. https://doi.org/10.1016/j.prosdent.2004.08.015
- Naconecy MM, Teixeira ER, Shinkai RS et al. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 2004;19: 192-8.
- Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004;13:358-66. https://doi.org/10.1097/01.id.0000144509.58901.f7
- Cabral LM, Guedes CG. Comparative analysis of 4 impression techniques for implants. Implant Dent 2007;16:187-94. https://doi.org/10.1097/ID.0b013e3180587b3f
- Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000;83:323-31. https://doi.org/10.1016/S0022-3913(00)70136-3
- Liou AD, Nicholls JI, Yuodelils R et al. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. Int J Prosthodont 1993;6:377-83.
- Craig. RG. Restorative dental materials. St.Louis CV Mosby CO. 1989. p.293-346.
- Phillips RW. Skinner's Science of Dental Materials. 8th ed., WB Saunders Co., Philadelphia, 1982. p.137- 156.
- Eames WB, Sieweke JC, Wallace SW et al. Elastomeric impression materials : Effect of bulk on accuracy. J Prosthet Dent 1979;41:304-7. https://doi.org/10.1016/0022-3913(79)90013-1
- Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implant in the edentulous jaw: a study of treatment from the time of prostheses placement to the first annual check up. Int J Oral Maxillofac Implants 1991;6:270-6.
- Kan JY, Rungcharassaeng K, Bohsali K et al. Clinical methods for evaluation implant framework fit. J Prosthet Dent 1999;81:7-13. https://doi.org/10.1016/S0022-3913(99)70229-5
- Tan KB, Rubenstein JE, Nicholls JI et al. Threedimensional analysis of the casting accuracy of one piece, osseointegrated implant retained prostheses. Int J Prosthodont 1993;6:346-63.