References
- Tolman DE, Laney WR. Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 1992;7:477-84.
- Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs. Int J Prosthodont 1995;8: 162-78.
- Binon PP. Evaluation of three slip fit hexagonal implants. Implant Dent 1996;5:235-48. https://doi.org/10.1097/00008505-199600540-00002
- Morgan MJ, James DF, Pilliar RM. Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants 1993;8:409-14.
- Dellow AG, Driessen CH, Nel HJ. Scanning electron microscopy evaluation of the interfacial fit of interchanged components of four dental implant systems. Int J Prosthodont 1997;10:216-21.
- O'Mahony A, MacNeil SR, Cobb CM. Design features that may influence bacterial plaque retention: a retrospective analysis of failed implants. Quintessence Int 2000;31:249-56.
- Hermann JS, Schoolfield JD, Schenk RK et al. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. J Periodontol 2001;72:1372-83. https://doi.org/10.1902/jop.2001.72.10.1372
- Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant-abutment interface. Int J Oral Maxillofac Implants 1997;12:527-40.
- Gross M, Abramovich I, Weiss EI. Microleakage at the abutment-implant interface of osseointegrated implants: A comparative study. Int J Oral Maxillofac Implants 1999;14:94-100.
- Steinebrunner L, Wolfart S, Bossmann K et al. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. Int J Oral Maxillofac Implants 2005;20:875-81.
- Gould TR, Brunette DM, Westbury L. The attachment mechanism of epithelial cells to titanium in vitro. J Periodontal Res 1981;16:611-6. https://doi.org/10.1111/j.1600-0765.1981.tb00999.x
- Byrne D, Houston F, Cleary R, et al. The fit of cast and premachined implant abutments. J Prosthet Dent 1998;80:184-92. https://doi.org/10.1016/S0022-3913(98)70108-8
- Prestipino V, Ingber A. Esthetic high strength implant -abutments. Part I. J Esthet Dent 1993;5:29-36. https://doi.org/10.1111/j.1708-8240.1993.tb00741.x
- Yildirim M, Edelhoff D, Hanisch O et al. Ceramic abutments-a new era in achieving optimal esthetics in implant dentistry. Int J Perodontics Restor Dent 2000;20:81-91.
- Abrahamsson I, Berglundh T, Glantz PO et al. The mucosal attachment at different abutments. J Clin Periodontol 1998;25:721-7. https://doi.org/10.1111/j.1600-051X.1998.tb02513.x
- ISO/DIS 14801. Dental implants - Dynamic continuous fatigue test. International Organization for Standardization, 2001.
- Graf H. Bruxism. Dent Clin North Am 1969;13 (3):659-65.
- Brunski JB, Hipp JA. In vivo forces on endosteal implants: a measurement system and biomechanical considerations. J Prosthet Dent 1984;51:82-90. https://doi.org/10.1016/S0022-3913(84)80112-2
- Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-5. https://doi.org/10.1016/0022-3913(89)90084-X
- Boggan RS, Strong JT, Misch CE et al. Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants. J Prosthet Dent 1999;82:436-40. https://doi.org/10.1016/S0022-3913(99)70030-2
- Ko YS, Son SG, Chung CH. Finite element stress analysis of osseointegrated implant prosthesis according to fitness of superstructure. J Korean Academy Stomatognathic Function and Occlusion 1996;12:173-91.
- Jung SH, Ma JS, Chung CH. A Comparative study on the fit in prostheses using premade gold cylinder and plastic cylinder. JKorean Acad Prosthodont 1999;37: 825-34.
- Kohal RJ, Papavasiliou G, Kamposiora P et al. Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants. Int J Prosthodont 2002; 15:189-94.
- Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
- Yuzugullu B, Avci M. The implant-abutment interface of alumina and zirconia abutments. Clin Implant Dent Relat Res. 2008;10:113-21. https://doi.org/10.1111/j.1708-8208.2007.00071.x
- Carr AB, Larsen PE, Papazoglou E et al. Reverse torque failure of screw-shaped implants in baboons: baseline data for abutment torque application. Int J Oral Maxillofac Implants 1995;10:167-74.
- Carr AB, Brunski JB, Hurley E. Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional gold and plastic cylinders. Int J Oral Maxillofac Implants 1996;11:589-98.
- Hurson S. Laboratory techniques to prevent screw loosening on dental implants. J Dent Technol 1996;13:30-7.