References
- Meyler TS, Blumberg AL, Purser P: Total skin electron beam therapy in mycosis fungoides. Cancer 42:1171-1176 (1978) https://doi.org/10.1002/1097-0142(197809)42:3<1171::AID-CNCR2820420321>3.0.CO;2-8
- Micaily B, Vonderheid EC, Brady LW, Andrews C: Total skin electron beam and total nodal irradiation for treatment of patients with cutaneous T-cell lymphoma. Int J Radiat Oncol Biol Phys 11:1111-1115 (1985) https://doi.org/10.1016/0360-3016(85)90057-4
- Maingon P, TrucG, Dalac S, et al: Radiotherapy of advanced mycosis fungoides: Indications and results of total skin electron beam and photon beam irradiation. Radiot Oncol 54:73-78 (2000) https://doi.org/10.1016/S0167-8140(99)00162-0
- Chen Z, Agostinelli AG, Wilson LD, Nath R: Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy. Int J Radiation Oncology Biol Phys 59:872-885 (2004) https://doi.org/10.1016/j.ijrobp.2004.02.046
- Tetennes PJ, Goodwin PN: Comparative study of superficial whole-body radiotherapeutic techniques using a 4 MeV non angled electyron beam. Radiology 122:219-226 (1977)
- Welson LW, Jones GW, Kim D, et al: Experience with total skin electron beam therapy in combination with extracorporeal photopheresis in the management of patients with erythrodermic (T4) mycosis fungoides. J Am Acad Dermatol 43:54-60 (2000) https://doi.org/10.1067/mjd.2000.105510
- Karzmark CJ, Loevinger R, Steele RE, Weissbluth M: A technique for large field superficial electron therapy. Radiology 74:633-644 (1960)
- Page V, Gardener A, Karzmark CJ: Patient dosimetry in the electron treatment of large superficial lesions. Radiology 94:635-641 (1970)
- Piermattei A, Rossi G, Azario L, Fidanzio A, Balducci M, Valentini V: Electron beam dosimetry of total skin electron therapy. Radiol Med 108:549-559 (2004)
- Gamble LM, Farrell TJ, Jones GW, Hayward JE: Twodimensional mapping of underdosed areas using radiochromic film for patients undergoing total skin electron beam radiotherapy. Int J Radiation Oncology Biol Phys 62:920-924 (2005) https://doi.org/10.1016/j.ijrobp.2005.02.057
- Weaver RD, Gerbi BJ, Dusenbery KE: Evaluation of dose variation during total skin electron irradiation using thermoluminescent dosimeters. Int J Radiat Oncol Biol Phys 33:475-478 (1995) https://doi.org/10.1016/0360-3016(95)00161-Q
- Antolak JA, Cundiff JH, Ha CS: Utilization of thermoluminescent dosimetry in total skin electron beam radiotherapy of mycosis fungoides. Int J Radiat Oncol Biol Phys 40:101-108 (1998) https://doi.org/10.1016/S0360-3016(97)00585-3
- Fraass BA, Roberson PL, Glatstein E: Whole-skin electron treatment: patient skin dose distribution. Radiology 146:811-814 (1983)
- Bufacchi A, Carosi A, Adorante N, et al: In vivo EBT radiochromic film dosimetry of electron beam for total skin electron therapy (TSET). Physica Medica 23:67-72 (2007) https://doi.org/10.1016/j.ejmp.2007.03.003
- Reynard E, Evans M, Devic S, et al: Rotational total skin electron irradiation with a linear accelerator. J Appl Clin Med Phys 9:123-134 (2008)
- Jones GW, Kacinski M, Wilson LD, et al: Total skin electron radiation in the management of mycosis fungoides: Consensus of the European Organization for Research and Treatment of Cancer cutaneous lymphoma project group. J Am Acad Dermatol 47:364-370 (2002) https://doi.org/10.1067/mjd.2002.123482
- Trump JG, Wright KA, Evans WW, et al: High-energy electrons for the treatment of extensive superficial malignant lesions. Am J Ront Rad Ther Nuc Med 69:623-629 (1953)
- Johnston DO, Smedal MI, Wright KA, Trump JG: Electron beam therapy of widespread superficial malignant lesions. Surg Clin North Am 39:1-6 (1959)
- Wu JM, Leung SW, Wang CJ, Chui CS: Lying-on position of total skin electron therapy. Int J Radiation Oncology Biol Phys 39:521-528 (1997) https://doi.org/10.1016/S0360-3016(97)00141-7
- Cheung T, Butson MJ, Yu PKN: Energy dependence corrections to MOSFET dosimetric sensitivity. Australasian Physical&Engineering Science in Medicine 32:16-20 (2009) https://doi.org/10.1007/BF03178623
- Cho SK, Choi SH, Na SH, et al: Determination of dose correction factor for energy and directional dependence of the MOSFET dosimeter in an anthropomorphic phantom. J Korea Asso Radiat Prot 31:97-104 (2006)
- Fuss M, Sturtewagen E, De Wagter C, Georg D: Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance. Phys Med Biol 52:4211-4225 (2007) https://doi.org/10.1088/0031-9155/52/14/013
- Todorovic M, Fischer M, Cremers F, Thom E, Schmidt R: Evaluation of GafChromic EBT prototype B for external beam dose verification. Med Phys 33:1321-1328 (2006) https://doi.org/10.1118/1.2188077
- Cheung T, Butson MJ, Yu PK: Independence of calibration curves for EBT gafchromic films of the size of high-energy X-ray. Applied Radiation and Isotopes 64:1027-1030 (2006) https://doi.org/10.1016/j.apradiso.2006.04.006
- http://online1.ispsorp.com/_layouts/Gafchromic/content/products/ebt2/pdfs/GAFCHROMICEBT2TechnicalBrief-Rev1.pdf
- Su FC, Liu Y, Stathakis S, Shi C, Esquivel C, Papanikolaou N: Dosimetry characteristics of GAFCHROMIC EBT film responding to therapeutic electron beams. Appl Radiat Isot 65:1187-1192 (2007) https://doi.org/10.1016/j.apradiso.2007.05.005
- Butson MJ, Cheung T, Yu PK: Weak energy dependence of EBT gafchromic film dose response in the 50 kVp∼10 MVp X-ray range. Appl Radiat Isot 64:60-62 (2006) https://doi.org/10.1016/j.apradiso.2005.07.002
- Khan FM: The Physics of Radiation Therapy. 3rd ed. Williams & Wilkins, Philadelphia, PA (2003), pp. 301
- AAPM Report 23: Total Skin Electron Therapy: Technique and Dosimetry. New York, NY, Amerian Institue of Physics, Inc.,335 East 45 Street (1987)