Abstract
This study deals with the measurement of reflectivity as well as the distance accuracy with Terrestrial Laser Scanner(TLS) using time of flight methods and near infrared wave length, for a variety of user-made targets. Especially, point clouds' reflection to several targets was measured with Gretag Macbeth il spectrophotometer in the office. And the distance accuracy in comparison to reference distance for TLS performance evaluation, was tested after scanning the user-made targets and measuring the inter-pillars distances over the precise EDM calibration baseline. The results of test was shown that except white resin objects, with approx. 10m and 170m inter-pillar distances, other targets achieved the distance accuracy of several millimeters(mm) with respect to standard distances. Future work should be concentrate on a few parameters influencing on the distance accuracy such as atmospheric correction, instrument correction, the additive constant or zero/index correction, etc.
본 연구는 시간차방식(TOF: Time of flight)과 근적외선 파장대역(760-3000nm)을 사용하는 지상라이다를 이용해서 다양한 사용자 타깃에 대해 반사도와 거리정확도를 테스트하였다. 특별히 사용자 타깃에 대한 측점군의 반사도는 실내에서 독일 Gretag Macbeth사의 i1 분광광도계로 측정되었다. 그리고 지상라이다의 성능 평가를 위해 정밀 EDM 검기선장에서 지상라이다를 이용해서 타깃을 스캐닝 하여 기준표석간 이격거리를 측정하여 표준거리와 비교하였다. 테스트 결과로서, 약 10m 와 170m 기준표석간 이격거리에 설치된 흰색 수지 타깃을 제외하고, 실험에 이용된 다른 타깃들의 거리측정값은 기준거리와 수 mm 정확도 차이를 보였다. 향후 대기보정, 장비보정, 부가상수와 같이 거리정확도에 영향을 미치는 변수들에 대한 연구가 필요할 것으로 사료 된다.