References
- Soffietti R, Ruda R, Trevisan E. Brain metastases: current management and new developments. Curr Opin Oncol 2008; 20:676-684 https://doi.org/10.1097/CCO.0b013e32831186fe
- Patel S, Macdonald OK, Suntharalingam M. Evaluation of the use of prophylactic cranial irradiation in small cell lung cancer. Cancer 2009;115:842-850 https://doi.org/10.1002/cncr.24105
- Kim IH, Choi DH, Kim JH, Ha SW, Park CI, Ahn HS. Effect of prophylactic cranial irradiation in acute lymphoblastic leukemia in children. J Korean Soc Ther Radiol 1989;7:269-278
- Shinn KS, Kang KM, Kim HK, Choi IB, Kim IA. Prophylactic cranial irradiation for acute lymphoblastic leukemia in childhood. J Korean Soc Ther Radiol 1996;14:137-148
- Meert AP, Paesmans M, Berghmans T, et al. Prophylactic cranial irradiation in small cell lung cancer: a systematic review of the literature with meta-analysis. BMC Cancer 2001;1:5 https://doi.org/10.1186/1471-2407-1-5
- Kalapurakal JA, Sathiaseelan V, Bista T, Marymont MH. Adverse impact of multileaf collimator field shaping on lens dose in children with acute leukemia receiving cranial irradiation. Int J Radiat Oncol Biol Phys 2000;48:1227-1231 https://doi.org/10.1016/S0360-3016(00)00723-9
- Cheng CW, Das IJ, Steinberg T. Role of multileaf collimator in replacing shielding blocks in radiation therapy. Int J Cancer 2001;96:385-395 https://doi.org/10.1002/ijc.1038
- De Meerleer GO, Derie CM, Vakaet L, Fortan LG, Mersseman BK Jr, De Neve WJ. Execution of a singleisocenter three-field technique, using a multileaf collimator or tray-mounted cerrobend blocks: effect on treatment time. Int J Radiat Oncol Biol Phys 1997;39:255-259
- Dirican B, Beyzadeoglu M, Turgay HT, Pak Y. Comparison of multileaf collimation and shield alloy blocks on an irregular target volume. Radiat Med 1996;14:293-296
- LoSasso T, Kutcher GJ. Multileaf collimation versus alloy blocks: analysis of geometric accuracy. Int J Radiat Oncol Biol Phys 1995;32:499-506 https://doi.org/10.1016/0360-3016(94)00455-T
- Cheng CW, Wong JR, Ndlovu AM, Das IJ, Schiff P, Uematsu M. Dosimetric evaluation and clinical application of virtual mini-multileaf collimator. Am J Clin Oncol 2003;26:e37- 44
- Gillin MT, Kline RW, Kun LE. Cranial dose distribution. Int J Radiat Oncol Biol Phys 1979;5:1903-1906 https://doi.org/10.1016/0360-3016(79)90581-9
- Yu JB, Shiao SL, Knisely JP. A dosimetric evaluation of conventional helmet field irradiation versus two-field intensitymodulated radiotherapy technique. Int J Radiat Oncol Biol Phys 2007;68:621-631 https://doi.org/10.1016/j.ijrobp.2006.12.004
- Keall P, Arief I, Shamas S, Weiss E, Castle S. The development and investigation of a prototype three-dimensional compensator for whole brain radiation therapy. Phys Med Biol 2008;53:2267-2276 https://doi.org/10.1088/0031-9155/53/9/004
- Goyal S, Yue NJ, Millevoi R, Kagan E, Haffty B, Narra V. Improvement in dose homogeneity with electronic tissue compensation over IMRT and conventional RT in whole brain radiotherapy. Radiother Oncol 2008;88:196-201 https://doi.org/10.1016/j.radonc.2008.03.001
- DeAngelis LM, Delattre JY, Posner JB. Radiationinduced dementia in patients cured of brain metastases. Neurology 1989;39:789-796 https://doi.org/10.1212/WNL.39.6.789
- Schipper J, Tan KE, van Peperzeel HA. Treatment of retinoblastoma by precision megavoltage radiation therapy. Radiother Oncol 1985;3:117-132 https://doi.org/10.1016/S0167-8140(85)80016-5
- Merriam GR Jr, Focht EF. A clinical study of radiation cataracts and the relationship to dose. Am J Roentgenol Radium Ther Nucl Med 1957;77:759-785
- Woo SY, Donaldson SS, Heck RJ, Nielson KL, Shostak C. Minimizing and measuring lens dose when giving cranial irradiation. Radiother Oncol 1989;16:183-188 https://doi.org/10.1016/0167-8140(89)90018-2
- Christ G, Denninger D, Dohm OS, Weigel B, Hones A, Paulsen F. Craniospinal radiotherapy in an advanced technique. Strahlenther Onkol 2008;184:530-535 https://doi.org/10.1007/s00066-008-1843-1
- South M, Chiu JK, Teh BS, Bloch C, Schroeder TM, Paulino AC. Supine craniospinal irradiation using intrafractional junction shifts and field-in-field dose shaping: early experience at Methodist Hospital. Int J Radiat Oncol Biol Phys 2008;71: 477-483 https://doi.org/10.1016/j.ijrobp.2007.10.029
Cited by
- 전뇌조사의 체적변조회전치료 시 두피선량 감소에 관한 평가 vol.15, pp.10, 2014, https://doi.org/10.5762/kais.2014.15.10.6187
- Linac 기반 VMAT 정위적 수술 뇌 병변 연구와 기존의 정위적 방사선 수술 비교 vol.15, pp.2, 2010, https://doi.org/10.7742/jksr.2021.15.2.239