DOI QR코드

DOI QR Code

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal

모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향

  • Sung, Hye-Jin (Department of Conservative Dentistry, Kyungpook National University School of Dentistry) ;
  • Ha, Jung-Hong (Department of Conservative Dentistry, Kyungpook National University School of Dentistry) ;
  • Kim, Sung-Kyo (Department of Conservative Dentistry, Kyungpook National University School of Dentistry)
  • 성혜진 (경북대학교 치의학전문대학원 치과보존학교실) ;
  • 하정홍 (경북대학교 치의학전문대학원 치과보존학교실) ;
  • 김성교 (경북대학교 치의학전문대학원 치과보존학교실)
  • Received : 2010.09.04
  • Accepted : 2010.09.13
  • Published : 2010.09.30

Abstract

Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.

연구목적: 니켈-티타늄 금속을 근관치료기구에 도입함으로써 근관형성과정이 매우 단순화되었다. 그러나 이러한 새로운 기구는 단점도 함께 가지고 있는데 그 중 하나가 근관내로 기구가 빨려 들어가는 경향이다. 본 연구에서는 니켈-티타늄 전동파일의 경사도가 screw-in effect에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 총 20개의 S-자형 투명레진블록 (Dentsply-Maillefer) 근관에서 두 군으로 나누어 실험하였는데 Profile군에서는 0.02, 0.04 그리고 0.06 경사도의 Profile (Dentsply-Maillefer)과 0.08, 0.10 그리고 0.12의 경사도의 GT Rotary file (Dentsply-Maillefer)을 사용하였고 K3군에서는 같은 경사도의 K3 file SybronEndo)을 사용하였으며, 분당 300회전의 일정한 속도에서 단일 pecking 동작으로 기구조작을 하였다. 특수한 장치를 고안하였으며 장치내 dynamometer를 이용하여 screw-in effect를 측정하여 one-way ANOVA로 통계처리하고 Tuckey's multiple range test로 사후검정하였다. 결과: Profile 군에서는 큰 경사도의 기구가 더 큰 screw-in force를 나타내었고 (p < 0.05), K3군에서는 0.08, 0.10. 및 0.12 경사도의 기구가 0.04 경사도의 기구에 비해, 0.08 및 0.12 경사도의 기구가 0.06 경사도의 기구에 비해 더 큰 screw-in force를 나타내었다 (p < 0.05). 결론: 기구의 경사도가 클수록 screw-in force가 많이 발생하는 것으로 생각되며, 경사도가 큰 전동화일을 사용시에는 screw-in force를 억제하기 위해 더 많은 주의가 요구될 것으로 생각된다.

Keywords

References

  1. Peter OA, Schonenberger K, Laib A. Effects of four Ni-Ti preparation techniques on root canal geometry assessed by micro computed tomography. Int Endod J 2001;34:221-230. https://doi.org/10.1046/j.1365-2591.2001.00373.x
  2. Schilder H. Cleaning and shaping the root canal. Dent Clin Nor Am 1974;18:269-296.
  3. Short JA, Morgan LA, Baumgartner JC. A comparison of canal centering ability of four instrumentation techniques. J Endod 1997;23:503-507. https://doi.org/10.1016/S0099-2399(97)80310-X
  4. Huh YJ, Kim SK. Change in root canal configuration using different file types and techniques. J Kor Acad Cons Dent 1997;22:291-304.
  5. Sjogren U, Hagglund B, Sundqvist G, Wing K. Factors Affecting the Long-term Result of Endodontic Treatment. J Endod 1990;16:498-504. https://doi.org/10.1016/S0099-2399(07)80180-4
  6. Camps JJ, Peter WJ. Torsional and Stiffness properties of nick-titanium k-files. Int Endod J 1995;28:239-243. https://doi.org/10.1111/j.1365-2591.1995.tb00307.x
  7. Glosson CR, Hallor RH, Dove SB, del Rio CE. A comparison of root canal preparations using nickel-titanium hand, nickel-titanium engine-driven, and K-flex endodontic instruments. J Endod 1995;21:146-151. https://doi.org/10.1016/S0099-2399(06)80441-3
  8. Schafer E. Root canal instruments for manual use: a review. Endod Dent Traumatol 1997;12:51-64.
  9. Yun HH, Kim SK. A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;95:228-233. https://doi.org/10.1067/moe.2003.92
  10. Ha JH, Jin MU, Kim YK, Kim SK. Comparison of screw-in effect for several nickel-titanium rotary instruments in simulated resin root canal. J Kor Acad Cons Dent 2010;35:267-272. https://doi.org/10.5395/JKACD.2010.35.4.267
  11. Oh SH, Park JK, Hur B, Kim HC. Comparison of screw-in effect of three NiTi file systems used by undergraduates. J Kor Acad Cons Dent 2006;31:477-484. https://doi.org/10.5395/JKACD.2006.31.6.477
  12. David B, Swartz AE, Skidmore JA, Griffin Jr. Twenty years of endodontic success and failure. J Endod 1983; 9:198-202. https://doi.org/10.1016/S0099-2399(83)80092-2
  13. Friedman S, Lost C, Zarrabian M, Trope M. Evaluation of success and failure after endodontic therapy using a glass ionomer cement sealer. J Endod 1995;21:384-390. https://doi.org/10.1016/S0099-2399(06)80976-3
  14. Malueg LA, Wilcox LR, Johnson W. Examination of external apical root resorption with scanning electron microscopy. Oral Surg Oral. Med Oral Pathol 1996;82: 89-93. https://doi.org/10.1016/S1079-2104(96)80383-0
  15. Smith CS, Setchell DJ, Harty FJ. Factors influencing the success of conventional root canal therapy-a fiveyear retrospective study. Int Endod J 1993;26:321-333. https://doi.org/10.1111/j.1365-2591.1993.tb00765.x
  16. Diemer F, Calas P. Effect of Pitch Length on the Behavior of Rotary Triple Helix Root Canal Instruments. J Endod 2004;30:716-718. https://doi.org/10.1097/01.DON.0000125877.26495.69
  17. Schrader C, Peter OA. Analysis of torque and force with differently tapered rotary endodontic instruments in vitro. J Endod 2005;31:120-123. https://doi.org/10.1097/01.don.0000137634.20499.1d
  18. Sattapan B, Palamara JE, Messer HH. Torque During Canal Instrumentation Using Rotary Nickel-Titanium Files. J Endod 2000;26:156-160. https://doi.org/10.1097/00004770-200003000-00007
  19. Thompson SA, Dummer PM. Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals, part 1. Int Endod J 2000;33:248-254. https://doi.org/10.1046/j.1365-2591.2000.00287.x
  20. Peter OA, Peter CI: Cleaning and shaping of the root canal system. In (ed) Hargreaves KM, Cohen S: Pathways of the pulp. 9th ed. Mosby, St. Louis;2006. p.311.
  21. Turpin YL, Chagneau F, Vulcain JM. Impact of two theoretical cross-sections on torsional and bending stresses of nickel-titanium root canal instrument models. J Endod 2000;26:414-417. https://doi.org/10.1097/00004770-200007000-00009
  22. Gutierrez JH, Brizuela C, Villota E. Human teeth with periapical pathosis after overinstrumentation and overfilling of the root canals: a scanning electron microscopic study. Int Endod J 1999;32:40-48. https://doi.org/10.1046/j.1365-2591.1999.00185.x
  23. Seltzer S, Soltanoff W, Sinai I, Goldenberg A, Bender IB. Biologic aspects of endodontics. Part III. Periapical tissue reaction to root canal instrumentation. Oral Surg Oral Med Oral Pathol 1968;26:534-546. https://doi.org/10.1016/0030-4220(68)90334-4

Cited by

  1. Mechanical and geometric features of endodontic instruments and its clinical effect vol.36, pp.1, 2011, https://doi.org/10.5395/JKACD.2011.36.1.1
  2. Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals vol.37, pp.4, 2012, https://doi.org/10.5395/rde.2012.37.4.215
  3. Comparative analysis of mechanical properties of differently tapered nickeltitanium endodontic rotary instruments vol.37, pp.4, 2018, https://doi.org/10.4012/dmj.2017-312