• Title/Summary/Keyword: Taper

Search Result 657, Processing Time 0.03 seconds

Transmission characteristics of a Linear Double Rectangular Taper (구형도파관 이중선형테이터의 전송특성 해석)

  • 이상설;변찬성
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.71-75
    • /
    • 1985
  • Transmission characteristics of a linear double rectangular taper is analysed by the trans-mission matrix of the taper. The total transmission matrix of the taper is obtained by multiplication of transmission matrices of smrjll taper sections which is decided into uniform length along the taper axis. The VSWR calculated from the transmission matrix is compared with those of Johnson and Matsumaru.

  • PDF

Step by Step Analysis of Root Canal Instrumentation with ProTaper® (ProTaper를 이용한 근관 형성의 단계별 분석)

  • Kim, Mi-Hee;Huh, Bock;Kim, Hyeon-Cheol;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.50-57
    • /
    • 2006
  • The purpose of this study was to investigate influence of each file step of $ProTaper^{(R)}$ system on canal transportation. Twenty simulated canals were prepared with either engine-driven $ProTaper^{(R)}$ or manual $ProTaper^{(R)}$, Group R-resin blocks were instrumented with rotary $ProTaper^{(R)}$ and group M-resin blocks were instrumented with manual $ProTaper^{(R)}$. Pre-operative resin blocks and post-operative resin blocks after each file step preparation were scanned. Original canal image and the image after using each file step were superimposed for calculation of centering ratio The image after using each file step alld image after using previous file step were superimposed for calculation of the amount of deviation. Measurements were taken horizontally at five different levels (1 2, 3, 4 and 5 mm) from the level of apical foramen. In rotary $ProTaper^{(R)}$ instrumentation group, centering ratio and the amount of deviation of each step at all levels were not significantly different (p>0.05). In manual $ProTaper^{(R)}$ instrumentation group, centering ratio and the amount of deviation of each step at all levels except of 1 mm were not significantly different (p>0.05). At the level of 1 mn, F2 file step had significantly large centering ratio and the amount of deviation (p<0.05). Under the condition of this study, F2 file step of manual ProTaper tended to transport the apical part of the canals than that of rotary $ProTaper^{(R)}$.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Comparison of shaping ability between various hybrid instrumentation methods with ProTaper (ProTaper를 사용한 다양한 hybrid instrumentation methods의 근관성형 효율 비교)

  • Hong, Eun-Sook;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.11-19
    • /
    • 2006
  • The purpose of this study was to compare and evaluate the shaping abilities of various hybrid instrumentation method using constant tapered file systems with $ProTaper\^{(R)}$ S1 and the difference between experts and inexperienced clinicians in use of NiTi file. Three hybrid methods used in this study were composed of $ProTaper\^{(R)}\;S1\;and\;K-Flexofile\^{(R)}\;(group S),\;ProTaper\^{(R)}\;S1\;and\;HeroShaper\^{(R)}\;(group\;H),\;and\;ProTaper\^{(R)}\;S1\;and\;ProFile\^{(R)}\;(group\;P)$respectively. The $ProTaper\^{(R)}$-alone method (group C) was introduced as a control group. After canal preparation, the lapse of time was recorded. The images of pre- and post-operative canal were scanned and superimposed. Amounts of instrumented canal widths and centering ratio were measured at apical 1, 2 and 3 mm levels and statistical analysis was performed In this study. both of the group C and S took more time to prepare canals than other groups, Inexperienced operators required more time for the entire preparation with the groups C and H than the experienced (p<0.05). And the centering ratio of group P were preferable to $ProTaper\^{(R)}$-alone method or the hybrid technique using stainless steel files. As such, within experienced operators, group H also showed better results in addition to the group P. Under these condition, the hybrid methods of each the $ProFile^{(R)}$ system and $HeroShaper^{(R)}$ with ProTaper are recommendable comparative to $ProTaper\^{(R)}$-alone method. According to the results, the hybrid instrumentation method is a more appropriate method of canal preparation than single file system for narrow or curved canals.

A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS (레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구)

  • Yang, In-Seok;Kang, In-Chol;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.393-401
    • /
    • 2005
  • The purpose of this study was to compare the canal configuration after shaping by ProTaper rotary files and ProTaper hand files in resin simulated canals. Forty resin simulated canals with a curvature of J-shape and S-shape were divided into four groups by 10 blocks each Simulated root canals in resin block were prepared by ProTaper rotary files and ProTaper hand files using a crown-down pressureless technique All simulated canals were prepared up to size $\#25$ file at end-point of preparation. Pre- and post-instrumentation images were recorded with color scanner. Assessment of canal shape was completed with an image analysis program. Measurements were made at 0, 1, 2, 3, 4, 5, 6 and 7 mm from the apex. At each level, outer canal width, inner canal width, total canal width, and amount of transportation from original axis were recorded. Instrumentation time was recorded. The data were analyzed statistically using independent t-test. The result was that ProTaper hand files cause significantly less canal transportation from original axis of canal body and maintain original canal configuration better than ProTaper rotary files, however ProTaper hand files take more shaping time.

EFFECT OF CANAL TAPERING IN TEETH OF VARIOUS APICAL SIZE & CROSS-SECTIONAL CONFIGURATION ON MICROLEAKAGE (다양한 치근단공 크기와 근관단면의 형태를 가지는 치아에서 taper의 정도가 미세누출에 미치는 영향)

  • Kim, Jung-Hee;Lee, Kyung-Ha;Lee, Se-Joon;Yu, Mi-Kyung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.95-101
    • /
    • 2005
  • The aim of this study was to evaluate the microleakage of teeth according to root canal preparation with & without apical enlargement in various size of apical foramen. 60 extracted one canal roots were cross-cutted at 5 mm from root apex and divided into two groups according to their apical foramen size of large (L) and small (S). Each group was subdivided into two groups accordance with their cross-sectional configuration at 5 mm from apex, round (R) and ovoid (O); SR Group, SO Group LR Group, LO Group. Each group was shaped in .02 taper by Quantec series Nickel-Titanium (NiTi) rotary file, obturated by lateral condensation method. Leakage was measured using a fluid transport model under 40 $cmH_2O$ pressure. After the leakage test, blocks which had showed the leakage retreated with .04 taper and ,06 taper and evaluated the degree of fluid filtration in each group. The data was analysed statistically using chi-square test and fisher's exact test. The results obtained were as follows : 1. Significant difference in leakage was found in groups which had different apical foramen size in .02 taper instrumentation (p < 0.05), but not in .04 taper instrumentation (p > 0.05) 2. The difference in microleakage according to the shape of canal was not evident at 5 mm from apex (p > 0.05). 3. There was correlation between .02 taper instrumentation and .04 taper instrumentation in LR group, LO group (p < 0.05).

Performance Improvement of Cylindrical Turbine Guide Bearings with Pad Leading-Edge Tapers for Vertical Hydro-Power Application: Effects of Taper Angle and Length (패드 선단 테이퍼를 갖는 수력 수직 원통형 터빈 가이드 베어링의 성능향상 - 테이퍼 각도와 길이의 영향)

  • Lee, An Sung;Jang, Sun-Yong;Park, Soo Man
    • Tribology and Lubricants
    • /
    • v.34 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • Cylindrical turbine guide bearings (TGBs) with simple plain pads have conventionally been used in vertical hydro-power turbine-generator applications in order to provide turbine runner shafts with smooth rotation guides and supports. To overcome low-load/low-eccentricity performance drawbacks, such as very low film stiffness and lack of design credibility in the stiffness values themselves, of conventional cylindrical TGBs, the introduction of a rotational-directional leading-edge taper to each partitioned pad, simply pad leading-edge taper, has been found to be very effective in enhancing their design-application availability and usefulness. In this study, we investigate the effects of taper angle and length for given taper heights in detail in order to systematically establish the effectiveness of design on the performance improvement of vertical hydro-power application cylindrical TGBs with pad leading-edge tapers. The analysis results with $4-Pad{\times}1-Row$ cylindrical TGBs show that the lubrication performance of the cylindrical TGBs is optimized with an approximate taper angle ratio of 0.8 and taper length ratio of 0.9. We conclude that the introduction of pad leading-edge tapers along with the optimization of taper designs can be very effective in improving the overall operation reliability of cylindrical TGBs and the rotordynamic characteristics of vertical hydro-power turbine-generator rotor-bearing systems as well, to which the TGBs are applied.

Effect of Taper Tension Profiles on Radial Stress of a Wound Roll in Roll-to-roll Winding Process (롤투롤 와인딩 시스템에서 테이퍼 장력과 감김롤 응력분포에 관한 연구)

  • Lee, Changwoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.2
    • /
    • pp.125-131
    • /
    • 2014
  • Winding is an integral operation in almost every roll-to-roll continuous process and center-winding is suitable and general scheme in the winding system. However, the internal stresses within center-wound rolls can cause damage such as buckling, spoking, cinching, etc. It is therefore necessary to analyze the relationship between taper tension in winding section and internal stress distribution within center-wound roll to prevent the winding failure. In this study, an optimal taper tension control method with parabolic taper tension profile for producing high quality wound roll was developed. The new logic was designed from analyzing the winding mechanism by using the stress model in center-wound rolls. The performance of the proposed taper tension profile was verified experimentally.

A STUDY OF INSERTION DEPTH OF GUTTA PERCHA CONES AFTER SHAPING BY NI-TI ROTARY FILES IN SIMULATED CANALS (레진모형 근관에서 Ni-Ti 파일로 근관성형 후 거타퍼챠콘의 근관내 삽입깊이에 대한 연구)

  • Cho, Hyun-Gu;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.550-558
    • /
    • 2007
  • The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25(n=10), .06 taper #25(n=10), ProTaper F2(n=10), HEROShaper .04 taper #25(n=10) and .06 taper #25(n=10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted(p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted(p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.

Stem and Stand Taper Model Using Spline Function and Linear Equation (Spline 함수(函數)와 선형방정식(線型方程式)을 이용한 수간(樹幹) 및 임분간곡선(林分幹曲線)모델)

  • Lee, Woo Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.1
    • /
    • pp.63-74
    • /
    • 1994
  • One of the essential factors to estimate the stem and stand growth is to correctly portray a stem form (profile). It is also required to numerically approximate a stem form in order to dynamically grasp and represent a stand growth. A whole stem form seems to be a conical form but a stem outline at various positions tapers off differently. Accordingly it is difficult to model a whole stand form with single taper equation. A stem taper equation with different coefficients on each subinterval can be useful tools to accurately portray a stem form. This article presents the derivation method of individual stem taper curve using spline function. It is also in this paper aimed to study how a stand taper curve car, be derived from the population of single stem taper curve in a stand. These taper equations numerically formulated enable to dynamically represent and prognosticate the development process of a stand and prepare the foundation of variety on growth model study and rational forest planning model.

  • PDF