Abstract
Method of protruding steel bar embedded in PHC pile for connecting with foundation plate is an intermediate form of fixed and hinged connection and has often been used in architectural structures such as apartment complex. However, mechanical properties of this method have not been proved and its construction process is not simple. In this study, therefore, by analyzing previous research and by considering ratio of steel bar and concrete in PHC pile, which is minimum reinforcement of rebar, the newly optimized method of reinforcing joint of PHC pile and foundation plate is suggested with respect to PHC pile type (PHC 450, PHC 500, and PHC 600). To assess mechanical properties (ultimate tensile and shear strength) of joint of PHC pile and foundation plate, full scale experimental tests are performed. As a result, all cases are satisfied with required design criteria and can be practically applied. Our results indicate that reduction of rebar reinforcement compared to previous method would lead cost saving in PHC pile construction.
PHC 말뚝에서 강선을 노출시켜 건축물의 기초판과 연결시키는 기존 강선남김 방식은 강결합과 힌지결합의 중간형태로 공동주택(아파트)과 같은 건축구조물에 흔히 사용되는 방법이다. 그러나 이 방법은 역학적인 성능이 검증되지 않았으며 시공과정도 복잡하다. 이에 본 연구는 기존 관련 연구의 결과를 분석하고, PHC 말뚝의 콘크리트 단면적 대비 강선면적 비인 0.3%를 말뚝 접합부의 최소 철근보강량으로 선정하여 PHC 말뚝과 기초판과의 최적의 철근보강 방법을 말뚝 규격별(PHC 450, PHC 500, 및 PHC 600)로 제시하였다. PHC 말뚝과 기초판 접합부의 역학적 성능(인장강도와 전단강도)을 평가하기 위해 실물크기의 실험을 실시하였다. 그 결과, 모든 경우에 대해 요구강도를 만족하였으며 실제 적용되어도 문제가 없음을 확인하였다. 본 결과는 기존 연구에서 제시되었던 접합부의 철근 보강량보다 그 양이 대폭 감소하는 것으로 나타나 PHC 말뚝 시공 시 원가 절감에도 기여할 것으로 판단된다.