Historical buildings in seismically active regions are severely damaged by earthquakes, since they certainly were not designed by the original builders to withstand seismic effects. In particular the reports after major ground motions indicate that earthquake-induced pounding between buildings may lead to substantial damage or even collapse of colliding structures. The research on structural pounding during earthquakes has been recently much advanced, although most of the studies are conducted on simplified single degree of freedom systems. In this paper a detailed pounding-involved response analysis of three adjacent structures is performed, concerning the main bodies of the "Quinto Orazio Flacco" school. The construction includes a main masonry building, with an M-shaped plan, and a reinforced concrete building, separated from the masonry one and realized along its free perimeter. By the analysis of the capacity curves obtained by suitable pushover procedures performed separately for each building, it emerges that masonry and reinforced concrete buildings are vulnerable to earthquake-induced structural pounding in the longitudinal direction. In particular, due to the geometric configuration of the school, a special case of impact between the reinforced concrete structure and two parts of the masonry building occurs. In order to evaluate the pounding-involved response of three adjacent structures, in this paper a numerical procedure is proposed, programmed using MATLAB software. Both a non-linear viscoelastic model to simulate impact and an elastic-perfectly plastic approximation of the storey shear force-drift relation are assumed, differently from many commercial softwares which admit just one non-linearity.

키워드

참고문헌

  1. Anagnostopoulos, S.A. and Spiliopoulos, K.V. (1992), "An investigation of earthquake induced pounding between adjacent buildings", Earthq. Eng. Struct. Dyn., 21, 289-302. https://doi.org/10.1002/eqe.4290210402
  2. CEN (2001), "Eurocode 2. Design of concrete structures - Part 1: General rules and rules for buildings", EN 1992-1.
  3. CEN (2003), "Eurocode 8. Design of structures for earthquake resistance - Part 1: general rules, seismic actions and rules for buildings ", UNI EN 1998-1:2003.
  4. CEN (2005), "Eurocode 6. Design of masonry structures. Part 1-1: General rules for reinforced and unreinforced masonry structures", UNI EN 1996-1-1:2006.
  5. FEMA (2000), "FEMA 356. Prestandard and commentary for the seismic rehabilitation of buildings", Federal Emergency Management Agency, Washington, D.C., USA.
  6. Jankowski, R. (2005), "Non-linear viscoelastic modelling of earthquake induced structural pounding", Earthq. Eng. Struct. Dyn., 34(6), 595-611. https://doi.org/10.1002/eqe.434
  7. Jankowski, R. (2006), "Analytical expression between the impact damping ratio and the coefficient of restitution in the non-linear viscoelastic model of structural pounding", Earthq. Eng. Struct. Dyn., 35(4), 517-524. https://doi.org/10.1002/eqe.537
  8. Jankowski, R. (2008), "Earthquake-induced pounding between equal height buildings with substantially different dynamic properties", Eng. Struct., 30, 2818-2829. https://doi.org/10.1016/j.engstruct.2008.03.006
  9. Jankowski, R. (2009), "Non-linear FEM analysis of earthquake-induced pounding between the main building and the stairway tower of the Olive View Hospital", Eng. Struct., 31, 1851-1864. https://doi.org/10.1016/j.engstruct.2009.03.024
  10. M.I.T. (2008), D.M. 14/01/2008. Norme Tecniche per le Costruzioni, Ministero Infrastrutture e Trasporti, Rome, Italy.
  11. Magenes, G. and Calvi, M. (1997), "In-plane seismic response of brick masonry walls", Earthq. Eng. Struct. Dyn., 26, 1091-1112. https://doi.org/10.1002/(SICI)1096-9845(199711)26:11<1091::AID-EQE693>3.0.CO;2-6
  12. Mistler, M., Butenweg, C. and Meskouris, K. (2006), "Modelling methods of historic masonry buildings under seismic excitation", J. Seismol., 10: 497-510. https://doi.org/10.1007/s10950-006-9033-z
  13. Muthukumar, S. and DesRoches, R. (2006), "A Hertz contact model with non-linear damping for pounding simulation", Earthq. Eng. Struct. Dyn., 35: 811-828. https://doi.org/10.1002/eqe.557
  14. P.C.M. (2005), Norme tecniche per il progetto, la valutazione e l'adeguamento sismico degli edifici, Testo integrato dell'Allegato 2 - Edifici - all'Ordinanza 3274 come modificato dall'OPCM 3431 del 3/5/05, Italy.
  15. Salonikios, T., Karakostas, C., Lekidis, V. and Anthoine, A. (2003), "Comparative inelastic pushover analysis of masonry frames", Eng. Struct., 25, 1515-1523. https://doi.org/10.1016/S0141-0296(03)00118-4
  16. Tomazevi , M. (1999), Earthquake resistant design of masonry buildings, Imperial College Press, London.
  17. Ye, K. and Li, L. (2009), "Impact analytical models for earthquake-induced pounding simulation", Front. Archit. Civil Eng. China, 3(2), 142-147. https://doi.org/10.1007/s11709-009-0029-y
  18. Zhu, P., Abe, M. and Fujino, Y. (2002), "Modelling three-dimensional non-linear seismic performance of elevated bridges with emphasis on pounding of girders", Earthq. Eng. Struct. Dyn., 31 , 1891-1913. https://doi.org/10.1002/eqe.194
  19. Zou, X.K. and Chan, C.M. (2005), "Optimal seismic performance-based design of reinforced concrete buildings using nonlinear pushover analysis", Eng. Struct., 27 , 1289-1302. https://doi.org/10.1016/j.engstruct.2005.04.001

피인용 문헌

  1. The influence of masonry infill on the seismic behaviour of RC frame buildings vol.44, 2012, https://doi.org/10.1016/j.engstruct.2012.05.023
  2. Performance-cost optimization of tuned mass damper under low-moderate seismic actions vol.25, pp.18, 2016, https://doi.org/10.1002/tal.1300
  3. Non-Linear Finite Element Analysis of Masonry Towers by Adopting the Damage Plasticity Constitutive Model vol.16, pp.5, 2013, https://doi.org/10.1260/1369-4332.16.5.791
  4. Evolutionary Modeling to Evaluate the Shear Behavior of Circular Reinforced Concrete Columns vol.2014, 2014, https://doi.org/10.1155/2014/684256
  5. Structural pounding between adjacent buildings subjected to strong ground motions. Part II: The effect of multiple earthquakes vol.42, pp.10, 2013, https://doi.org/10.1002/eqe.2284
  6. Integration Algorithm for Covariance Nonstationary Dynamic Analysis of SDOF Systems Using Equivalent Stochastic Linearization vol.15, pp.02, 2015, https://doi.org/10.1142/S0219455414500448
  7. Earthquake-Induced Lateral-Torsional Pounding between Two Equal Height Multi-Storey Buildings under Multiple Bi-Directional Ground Motions vol.16, pp.5, 2013, https://doi.org/10.1260/1369-4332.16.5.845
  8. On the Fresh/Hardened Properties of Cement Composites Incorporating Rubber Particles from Recycled Tires vol.2014, 2014, https://doi.org/10.1155/2014/876158
  9. Seismic vulnerability assessment of historical centers at urban scale 2017, https://doi.org/10.1080/15583058.2017.1402969
  10. Influence of bi-directional seismic pounding on the inelastic demand distribution of three adjacent multi-storey R/C buildings vol.6, pp.1, 2014, https://doi.org/10.12989/eas.2014.6.1.071
  11. Optimum design of viscous dissipative links in wall-frame systems vol.25, pp.9, 2016, https://doi.org/10.1002/tal.1265
  12. On the prediction of shear brittle collapse mechanisms due to the infill-frame interaction in RC buildings under pushover analysis vol.121, 2016, https://doi.org/10.1016/j.engstruct.2016.04.044
  13. Parametric Identification of Nonlinear Devices for Seismic Protection Using Soft Computing Techniques vol.639-640, pp.1662-8985, 2013, https://doi.org/10.4028/www.scientific.net/AMR.639-640.118
  14. Proposal of a Incremental Modal Pushover Analysis (IMPA) vol.13, pp.6, 2010, https://doi.org/10.12989/eas.2017.13.6.539