A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights

여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구

  • Published : 2010.01.10

Abstract

In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

Keywords

References

  1. Chang, H. J., 2008, Fundamental studies on indoor thermal environment in an apartment house utilizing wind driven ventilation in summer, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, Vol. 2, No. 1, pp. 22-27.
  2. Tanaka, J, 2008, Architectural Environmental Engineering, Inoueshoin, Tokyo, pp. 172-173.
  3. ISO 7730, 1984, Moderate Thermal Environments-Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort, ISO.