DOI QR코드

DOI QR Code

Rapid Spectrophotometric Determination of Trace Amounts of Cyanide and Hydrogen Cyanide Using p-Aminoacetanilide in Various Samples

여러 가지 시료 중에 p-Aminoacetanilide를 사용하여 Cyanide와 Hydrogen Cyanide 흔적량의 신속한 분광광도법 측정

  • Parmar, Prachi (Department of Chemistry, Govt. V.Y.T. Autonomous College Durg) ;
  • Pillai, Ajai Kumar (Department of Chemistry, Govt. V.Y.T. Autonomous College Durg) ;
  • Gupta, Vinay Kumar (School of studies in Chemistry, Pt. Ravishankar Shukla University)
  • Published : 2010.02.20

Abstract

Keywords

INTRODUCTION

A highly toxic substance, cyanide is widely used for the extraction of metals in electroplating industry, for surface treatments and in the production of various resin monomers. Major sources of cyanide in addition to those from the above mentioned industries include, exhaust from vehicle emissions and cigarette smoke.1 Typical signs of acute cyanide poisoning include tachypnoea, headache, vertigo, lack of motor coordination, weak pulse, cardiac arrhythmias, vomiting, stupor, convulsions, eye irritation coma and death.2

Hydrogen cyanide is reported to be present in cigarette smoke, the concentration of which varies according to the variety of the cigarette. A cigarette without filter is reported to liberate 500 μg of hydrogen cyanide while filtered cigarettes liberate only 100 μg.3-4 Cyanide is well absorbed via gastrointestinal tract or skin and rapidly absorbed via respiratory tract. Once absorbed, cyanide is rapidly and ubiquitously distributed throughout the body, although the highest level is typically found in liver, lungs, blood and brain.5 The lethal dose for human beings normally varies between 0.5 to 3.5 mg/kg of body weight.6

Due to its highly toxic nature, a method for its determination has been an area of interest for analytical chemists. Several methods have been developed for the determination of cyanide, which include HPLC,7 GC-MS,8 capillary electrophoresis,9 photometry,10 electrochemical sensor,11 ion chromatography,12 chromatography,13 indirect determination by atomic absorption spectrometry,14 electrochemical method,15 spectrofluorimetry,16 and spectrophotometry.17-21

In this communication, a spectrophotometric method has been proposed which is based on the earlier reported method of conversion of cyanide to cyanogen chloride by chloramine-T.22 Cyanogen chloride thus produced is reacted with pyridine to form an additional product which subsequently condenses with p-aminoacetanilide to form a coloured product measurable at 485 nm. Although a number of spectrophotometric methods have been reported for the determination of cyanide, the most of them use bromine water which is toxic in nature, few of the reported method use benzidine and other amino like p-phenylene diamine, compounds for coupling which are carcinogenic (Table 4). Both these drawbacks are removed by using chloramine-T and p-aminoacetanilide.

 

EXPERIMENTAL

Apparatus and reagents

A Toshniwal model TVSP 25 spectrophotometer was used for spectral measurements. pH measurements were made with systronics pH meter model 331. Fritted midget impingers (diameter~10 mm) of 35 mL capacity were used for air sampling. Flow rate adjustable calibrated rotameters were used for measuring the air flow. All chemicals used in this work were of analytical grade, double distilled water was used throughout.

Cyanide stock (Merck) -1 mg mL-1 stock solution of cyanide was prepared by dissolving 250 mg of potassium cyanide in 100 mL-1 water. Working standards were prepared from this stock by appropriate dilution. Pyridine reagent ‒3 mL of concentrated hydrochloric acid was mixed with 18 mL of pyridine (Merck) and 12 mL of water followed by addition of 30 mL of 0.5% aqueous solution of p-aminoacetanilide (Merck). Chloramine-T (Merck) ‒0.03% (w/v) chloramine-T solution was prepared by dissolving 0.03 g chloramine-T in distilled water and diluting it to the mark in a 100 mL volumetric flask. Stock Solution of fenvalerate Pesticide (Northern Mineral Limited, India) 1 mg mL-1 was prepared in ethanol. Working standards were prepared by appropriate dilution of the stock. Sodium hydroxide solution (Loba chemie, Mumbai) 2 M aqueous solution was prepared.

Procedure

Preparation of calibration curve: To an aliquot of an aqueous solution containing 0.4 ~ 5.0 μg of cyanide was taken in a 25 mL graduated test tube series. To it 1 mL of pyridine-p-aminoacetanilide reagent was added followed by addition of 1 mL of chloramine-T and reaction condition thermostated at 30 ℃. The solution was diluted with double distilled water and allowed to stand for 2 ~ 3 min for complete colour development. The absorption of the standard solution of the cyanide with different concentrations was recorded at 485 nm against reagent blank.

Determination

Determination of hydrogen cyanide in air samples: Contaminated air of nearby location of steel plant was drawn into two midget impingers, each containing 10 mL of 0.1 M NaOH solution connected to a source of suction in the environment at a flow rate of 0.25 L min-1 for 15 min. After sampling, aliquots of the absorbing solution were analyzed as described above and the results confirmed by a reported method20 (Table 3).

Determination of cyanide in pesticide: Stock solution of fenvalerate pesticide (Northern mineral limited, India) 1 mg mL-1 was prepared in ethanol. Working standards were prepared by appropriate dilution of the stock. To known amount of pesticide taken separately in a series of 25 mL graduate test tube, 1.0 mL of 2 M sodium hydroxide solution was added and allowed to stand for complete hydrolysis. After 5 min, 1 mL of 2 M hydrochloric acid, 1 mL of pyridine-p-aminoacetanilide reagent and 1 mL of chloramine-T were added in sequence. The solution was kept for 5 min for complete colour development. The resulting orange red dye was made up to the mark and measured at 485 nm against a reagent blank that gave negligible absorbance at this wavelength (Table 3).

Coke oven effluents: In coke oven effluent, 1 mL of pyridinep-aminoacetanilide reagent and 1 mL of chloramine-T were added. The solution stand for 5 min, resulting orange red dye was made up to the mark and measured at 485 nm against a reagent blank that gave negligible absorbance at this wavelength (Table 3).

 

RESULT AND DISCUSSION

Absorption spectra

Final colored product is stable for 30 min and shows maximum absorbance at 485 nm (Fig. 1) where as the reagent blank has negligible absorbance at this wave length. Linear range is obeyed over the concentration range of 0.016 to 0.2 μg mL-1 of cyanide. The molar absorptivity and Sandell’s sensitivity are 9.63 × 104 L mol-1 cm-1 and 0.0003 μg cm-2 respectively. The slope, intercept, and the correlation coefficient evaluated by least squares regression analysis are also included (Table 1).

Table 1.(Y = bx + a), x is the concentration in μg mL-1, **n = 6.

Fig. 1.Absorption spectra of the dye.

Effect of reagent concentration

Effects of reagent concentration on the absorbance value were evaluated. It was found that 1 mL of chloramines-T (0.03%) and 1 mL of pyridine-p-aminoacetanilide reagent was required for complete colour development.

Effect of temperature, time and pH

Optimum results were obtained when the pH of the final solution was between 5.0 ~ 5.5. Above this pH range decrease in the absorbance was observed and dye too became unstable. It was found that temperature range of 10 ~ 30 ℃ had no adverse effect on the colour development. The colour development was completed within 5 min after addition of the reagent and the colour remained stable for 30 min.

Reproducibility

Reproducibility of the method was checked by 6 replicate analysis of the cyanide solution containing 0.3 μg of cyanide in 25 mL final solution. The standard deviation and relative standard deviation were found to be ±0.0015 and 0.26% respectively.

Effect of foreign species

The possibilities of interference from ions, which generally co-exist with cyanide, were studied by adding known amounts of different organic pollutants and inorganic ions to the test solution containing a total amount of 4 μg of cyanide per 25 mL of final volume. Interference from NO2‒ and NO3‒ was removed up to 100 μg mL-1 by addition of 0.2% sulfamic acid. Interference from various organic pollutants and metal ions was not found. Masking of ions with EDTA solution increases the tolerance limit to a considerable extent. Thiocyanite shows positive interference since it also forms cyanogens chloride when treated with chloramines-T. The tolerance limit of various interferents is shown in Table 2.

Table 2.aThe amount causing an error of ±2% in absorbance value.

Table 3.aMean of three replicate analysis. bResult of analysis of Plant Air. cResults of analysis of pesticide. dResult of analysis of coke oven effluents.

Table 4.Comparison with other spectrophotometric method

Application. Previously, sample of industrial air, pesticides and coke oven effluent were analyzed by the recommended assay. The results of the determinations were in good agreement with those made with a well known spectrophotometric method.20

References

  1. Tina Petrova Simeonova, Lawrence Fishbein, Fairfax, Virginia, USA, World Health Organization, Geneva, 2004.
  2. Pritchard, J. D.; CHAPD HQ, HPA 2007, Version 2.
  3. Health Canada 2002 Where there’s smoke there’s hydrogen cyanide. Ottawa, Ontario, Health Canada, Healthy Environments and Consumer Safety Branch. Available http://www.hc-sc.gc.ca/hesesc/tobacco/legislation/warnings/e_o.html#3.
  4. Drochiou, G.; Mangalagiu, I.; Tararu, V. Analyst 2000, 125, 939. https://doi.org/10.1039/b001244k
  5. Lam, K. K.; Lau, F. L. An Incident of Hydrogen Cyanide Poisoning Am J. Emerg. Med. 2000, 18, 172-5.
  6. Yenneshland, B.; Conn, E. Cyanide in Biology, Wiley Interscience, New-York, 1991, p.11.
  7. Akiyama, H.; Toida, T.; Sakai, S.; Amakura, Y.; Kondo, K.; konishi, Y. S. J. Health Sci. 2006, 52, 73-77. https://doi.org/10.1248/jhs.52.73
  8. Nishikawa, M. M.; Tsuchihashi, H. Journal of Health Science 2000, 46, 81-88. https://doi.org/10.1248/jhs.46.81
  9. Katerina, P.; Glatz, Z Journal of Chromatography A 2006, 1120, 268-272. https://doi.org/10.1016/j.chroma.2006.03.030
  10. Yongsheng, Y.; R. Brownell, C.; Sadrieh, N.; May, C.; Alfred, V. D. G.; Lyon, R. C.; Faustino, P. J. J. of Pharma and biomedical Anal. 2007, 43, 1358-1368. https://doi.org/10.1016/j.jpba.2006.11.010
  11. Lindsay, A. E.; Danny, O. H. Analytical Chimica Acta 2006, 558, 158-163. https://doi.org/10.1016/j.aca.2005.11.036
  12. Christison, T. T.; Rohrer, J. S. J. Chromatography A. 2007, 1155(1), 31-39. https://doi.org/10.1016/j.chroma.2007.02.083
  13. Logue, B. A.; Kirschten, N. P.; Petrikovics, I.; Moser, M. A.; Rock Wood, G. A.; Baskin, S. I. J. Chromatogr. B. 2005, 819, 237. https://doi.org/10.1016/j.jchromb.2005.01.045
  14. Noroozifar, M.; Motlagh, M. K. Anal. Chim. Acta 2005, 528, 269. https://doi.org/10.1016/j.aca.2004.10.056
  15. Abbspour, A.; Asadi, M.; Ghaffarinejad, A.; Safaei, E. Talanta 2005, 66, 931. https://doi.org/10.1016/j.talanta.2004.12.062
  16. Ruiz, D. L. E.; Garcia, E. A.; Garcia, M. E. D. Analyst 2000, 125, 2100. https://doi.org/10.1039/b004765l
  17. Nagaraja, P.; Hemantha, M. S; Yathirajan, H. S.; Prakash, J. S. Anal. Sci. 2002, 19, 1027.
  18. Agrawal, O.; Sunitha, G.; Gupta, V. K. J. Chin. Chem. Soc. 2005, 52, 51.
  19. Deep, B.; Balasubramanian, N.; Nagaraja, K. S. Anal. Lett 2003, 36, 2865. https://doi.org/10.1081/AL-120025261
  20. Verma, A.;.Gupta, V. K. Asian Journal of Chemistry 1996, 8, 4.
  21. Drochioiu, G.; Mangalagiu, I.; Avram, E.; Popa, K.; Dirtu, A. C.; Analytical Science 2004, 20, 1443. https://doi.org/10.2116/analsci.20.1443
  22. Afkhami, A.; Sarlak, N.; Zarei, A. R. Talanta 2007, 71, 93-899.
  23. Katki, K. S. Analyst 1957, 82, 24. https://doi.org/10.1039/an9578200024
  24. Sunita, S.; Gupta, V. K. J. Indian Chem. Society 1987, LXIV, 431-433.
  25. Upadhyay, S.; Gupta, V. K. Analyst 1984, 109, 1619 https://doi.org/10.1039/an9840901619
  26. Archer, E. E. Analyst 1988, 69, 370. https://doi.org/10.1039/an9446900370
  27. Padmarajaiah, N.; Mattighatta, S.; Kumar, H.; Hemmige, S.; Jainara, V.; Prakash, S. Analytical Science 2002, 18, 1027. https://doi.org/10.2116/analsci.18.1027
  28. Amlathe, S.; Gupta, V. K. Bull. Soc. Chim. Belg 1988, 97(5), 395.
  29. Saad, S. M. H.; Mohamed, S. A. H.; Ali, E. K. Talanta 2007, 71, 1088. https://doi.org/10.1016/j.talanta.2006.06.010
  30. Bark, L. S.; Higson, H. G. Talanta 1964, 11, 621. https://doi.org/10.1016/0039-9140(64)80073-4

Cited by

  1. A review of rapid and field-portable analytical techniques for the diagnosis of cyanide exposure vol.960, 2017, https://doi.org/10.1016/j.aca.2016.12.039