외피 열성능에 따른 건물에너지효율등급 분석 연구

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope

  • 김치훈 (경북대학교 대학원 건축공학과) ;
  • 안병립 (경북대학교 대학원 건축공학과) ;
  • 김지연 (인하대학교 대학원 건축공학과) ;
  • 장철용 (한국에너지기술연구원)
  • 발행 : 2009.10.30

초록

According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

키워드

참고문헌

  1. 박효순 외, '공동주택 발코니개조가 건물에너지효율등급에 미치는 영향에 관한 연구', 대한건축학회 논문집, 제22권, 제3호, pp. 295-302, 2006
  2. 김지연 외, '공동주택의 발코니 확장에 따른 열환경 성능 평가 및 개선방법에 관한 연구, 한국태양에너지학회 춘계학술발표대회 논문집, pp. 67-72, 2006