DOI QR코드

DOI QR Code

Static and dynamic analytical and experimental analysis of 3D reinforced concrete panels

  • Numayr, K. (Civil Engineering Department, Jordan University of Science and Technology) ;
  • Haddad, R. (Civil Engineering Department, Jordan University of Science and Technology)
  • 투고 : 2008.06.16
  • 심사 : 2009.03.17
  • 발행 : 2009.06.20

초록

A three-dimensional panel system, which was offered as a new method for construction in Jordan using relatively high strength modular panels for walls and ceilings, is investigated in this paper. The panel consists of two steel meshes on both sides of an expanded polystyrene core and connected together with a truss wire to provide a 3D system. The top face of the ceiling panel was pored with regular concrete mix, while the bottom face and both faces of the wall panels were cast by shotcreting (dry process). To investigate the structural performance of this system, an extensive experimental testing program for ceiling and wall panels subjected to static and dynamic loadings was conducted. The load-deflection curves were obtained for beam and shear wall elements and wall elements under transverse and axial loads, respectively. Static and dynamic analyses were conducted, and the performance of the proposed structural system was evaluated and compared with a typical three dimensional reinforced concrete frame system for buildings of the same floor areas and number of floors. Compressive strength capacity of a ceiling panel is determined for gravity loads, while flexural capacity is determined under the effect of wind and seismic loading. It was found that, the strength and serviceability requirements could be easily satisfied for buildings constructed using the three-dimensional panel system. The 3D panel system is superior to that of conventional frame system in its dynamic performance, due to its high stiffness to mass ratio.

키워드

참고문헌

  1. ACI Committee 318 (2005), Building Code Requirements for Structural Concrete (ACI 318M-05), American Concrete Institute, Farmington Hills, Mich., USA
  2. ASTM Book of Standards (2005), Construction: Concrete and Aggregates (V. 04-05), American Society for Testing Materials, Ann Arbor, MI, USA
  3. Benayoune, A., Samad, A.A., Trikha, D.N., Abang, A.A. and Ashrabov, A.A. (2006), 'Structural behaviour of eccentrically loaded precast panels', Constr. Build. Mater., 20(9), 713-724 https://doi.org/10.1016/j.conbuildmat.2005.02.002
  4. Benayoune, A., Samad, A.A., Abang, A.A. and Trikha, D.N. (2007), 'Response of pre-cast reinforced composite sanwich panels to axial loading', Constr. Build. Mater., 21(3), 677-685 https://doi.org/10.1016/j.conbuildmat.2005.12.011
  5. Lan, S., Lok, T.-S. and Heng, L. (2005), 'Composite structural panels subjected to explosive loading', Constr. Buil. Mater., 19(7), 387-395
  6. Mo, Y.L. and Chan, J. (1996), 'Behaviour of reinforced-concrete-framed shear walls', Nuclear Eng. D., 55(1), 55-68
  7. Nilson, A.H. (1987), Design of Prestressed Concrete, 2nd edition, John Wiley & Sons Inc., Canada
  8. Nilson, A.H. (1997), Design of Concrete Structures, 12th edition, McGraw-Hill, Singapore
  9. Paulay, T. and Priesley, M.J. (1992), Seismic Design of Reinforced Concrete and Masonry Buildings, Wiley, New York