Abstract
PEB system is more economical when compared with structures commonly used Hot rolled and welded light H-beam was introduced in the Standard Livestock Housing. This study suggested more economical technology for structural design by the reduction of live load, relief of deflection limit and reduction of importance factor. And, when applying wind Load as a result of examination with Low Rise Building Systems Manual considering open model, we can know that when the wind load is big, enclosed model is more stable than open model. In short, Suggesting more economical model and providing the method to reduce natural disaster, by the application of PEB system and the development of technology for structural design, are considered to strengthen the competitive power of farmhouse.