DOI QR코드

DOI QR Code

Ray Tracing of a Plastic Aspheric Lens by Considering Index Distribution Induced from Injection Molding

사출성형시 굴절율 변화를 고려하기 위한 플라스틱 비구면 렌즈의 광선추적기법

  • 엄혜주 (서울산업대학교 에너지환경대학원 Nano-IT 공학과) ;
  • 박근 (서울산업대학교 기계설계 자동화공학부)
  • Published : 2009.04.01

Abstract

The present study covers an integrated simulation method to evaluate optical performance of an aspheric plastic lens by connecting an injection molding analysis with a ray tracing simulation. Traditional ray tracing methods have based on the assumption that the optical properties of a lens are homogeneous throughout the entire volume. This assumption is to a certain extent unrealistic for injection-molded plastic lenses because material properties vary at every point due to the injection molding effects. To take into account the effects of the inhomogeneous optical properties of the molded lens, a numerical scheme is developed to calculate the distribution of refractive index induced from the injection molding process. This index distribution is then reflected onto CODE $V^{(R)}$ simulation and used to calculate ray paths in inhomogeneous media. The proposed tracing scheme is implemented on the tracing of an aspheric lens for a mobile phone camera module.

Keywords

References

  1. W. J. Smith, 1990, Modern Optical Engineering, McGraw-Hill
  2. A. W. McFarland, J. S. Colton, 2004, Production and analysis of injection molded micro-optic components, Polym. Eng. Sci., Vol. 44, pp. 4-579 https://doi.org/10.1002/pen.20051
  3. K. Park, S. K. Lee, K. S. Jeon, P. S. Mo, 2005, A new ray tracing method of a plastic lens connected with finite-element analysis, J. Kor. Soc. Prec. Engng., Vol. 22, pp. 100-107
  4. K. Park, H. J. Eom, J. P. Kim, W. J. Joo, 2007, Evaluation of optical performance for an aspheric lens connecting with FE analysis of injection molding, Trans. Mater. Proc., Vol. 16, pp. 25-30 https://doi.org/10.5228/KSPP.2007.16.1.025
  5. Optical Research Associates, 2007, CODE V 9.8 User's manual
  6. A. Sharma, D. V. Kumar, A. K. Ghatak, 1982, Tracing rays through graded-index media: a new method, Appl. Opt., Vol. 21, p. 984 https://doi.org/10.1364/AO.21.000984
  7. K. Park, W. Joo, 2008, Numerical evaluation of a plastic lens by coupling injection molding analysis with optical simulation, Jap. J. Appl. Phys., Vol. 47, pp. 8402-8407 https://doi.org/10.1143/JJAP.47.8402