In this paper, variable characteristic ratio algorithm based on oscillometric method is proposed to enhance the accuracy of blood pressure measurement. We combined the slope-based approach and fuzzy inference technique to change the characteristic ratios of height-based method. The proposed algorithm was assessed on 255 measurements from 85 subjects and compared with the conventional height-based algorithm. The testing results showed that the developed algorithm achieved an overall grade A for both systolic and diastolic blood pressures according to the BHS protocol. And, mean standard deviation between the observers and the developed algorithm were 5.71mmHg and 6.29mmHg for systolic and diastolic pressures respectively, which also fulfilled the AAMI criteria. In conclusion, this algorithm was successfully developed and recommended for further clinical trials with the wider adult population.

키워드

참고문헌

  1. J.M. Shim, J.K. Kim, M.I. Kwon, D.S. Kim, "Comparison of Arterial Blood Pressure Measured with an Aid of Non-invasive and Invasive Methods", J. Korean Soc. Anesthesiologists, Vol.25, No.1, pp.46-52, 1992 https://doi.org/10.4097/kjae.1992.25.1.46
  2. W.G. Kim, K.Y. Shin, J.H. Mun, "The Development of a Cuff for the Accuracy Enhancement of Sphygmomanometer", J. KSPE, Vol.22, No.5, pp.181-188, 2005
  3. D.K. Roh, Y.S. Lee, J.H. Jie, S.B. Park, K.H. Lee, H.K. Kim, "Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method", J. Biomed. Eng. Res., Vol.24, No.4, pp281-286, 2003
  4. C.C. Tyan, S.H. Liu, J.Y. Chen, J.J. Chen, W.M. Liang, "A Novel Noninvasive Measurement Technique for Analyzing the Pressure Pulse Waveform of the Radial Artery", IEEE Trans. Biomed. Eng., Vol.55, No.1, pp.299-297, 2008
  5. L.A. Geddes, M. Vaelr, C. Combs, D. Rcincr, C.F. Babs, "Characterization of the Oscillometric Method for Measuring Indirect Blood Pressure", Ann. Biomed. Eng., vol.10, pp.271-280, 1982 https://doi.org/10.1007/BF02367308
  6. G. Drzewiecki, R. Hood, H. Apple, "Theory of the Oscillometric Maximum and the Systolic and Diastolic Detection Ratios," Ann. Biomed. Eng., vol. 22, pp.88-96, 1994 https://doi.org/10.1007/BF02368225
  7. JCTB Moraes, M. Cerulli, PS. Ng, "Development of a New Oscillometric Blood Pressure Measurement System", IEEE Computers in Cardiology, Vol.26, pp.467-470, 1999
  8. S. Colak, C. Isik, "Systolic Blood Pressure Classification", Proc. Int. Joint Conf. Neural Networks, Vol.1, pp.627-630, 2003
  9. M.O. Al-Jaafreh, A.A. Al-Jumaily, "Type-2 Fuzzy System Based Blood Pressure Parameters Estimation", 2nd Asia Int. Conf. Modelling & Simulation, pp.953-958, 2008
  10. C. Huo, J. Wang, J. Zhang. S. Liu, "Blood Pressure Measurement Based on Wavelet Analysis and Fuzzy Inference Method", Proc. 6th World Cong. Intelligent Control and Automation, pp.4382-4386, 2006
  11. C.T. Lin, S.H. Liu, J.J. Wang, Z.C. Wen, "Reduction of Interference in Oscillometric Arterial Blood Pressure Measurement Using Fuzzy Logic,", IEEE Trans. Biomed. Eng., Vol 50, No.4, pp.432-441, 2003 https://doi.org/10.1109/TBME.2003.809502
  12. JCTB Moraes, M. Cerulli, PS. Ng, "A Strategy for Determination of Systolic, Mean and Diastolic Blood Pressures from Oscillometric Pulse Profiles", IEEE Computers in Cardiology, Vol.27, pp.211-214, 2000
  13. M. Ursino, C. Cristalli, "A Mathematical Study of Some Biomechanical Factors Affecting the Oscillometric Blood Pressure Measurement", IEEE Trans. Biomed. Eng., Vol. 43, No.8, pp.761-778, 1996 https://doi.org/10.1109/10.508540
  14. S. Colak, C. Isik, "Fuzzy Oscillometric Blood Pressure Classification", 22nd Int. Conf. North Am. Fuzzy Information Processing Society, pp.208-213, 2003
  15. C.T. Lin, C.S.G. Lee, Neural Fuzzy Systems: A Neural-Fuzzy Synergism to Intelligent Systems, Englewood Cliffs, Prentice-Hall, 1996