Response of Bridge Piers Retrofitted by Stainless Steel Wire under Simulated Seismic Loading

내진 모사하중에 의한 스테인레스강 와이어 보강 교각의 응답

  • 최준혁 (대한컨설탄트 철도부) ;
  • 김성훈 (서울산업대학교 토목공학과) ;
  • 이도형 (배재대학교 건설환경철도공학과)
  • Received : 2009.06.12
  • Accepted : 2009.07.17
  • Published : 2009.08.27

Abstract

In the present study, a new seismic retrofitting method that employs both a stainless steel wire mesh and a permeable polymer concrete mortar was proposed for reinforced concrete bridge piers with nonseismic design details. For this purpose, a total of six nonseismically designed bridge piers were tested under lateral load reversals. The test results reveal that nonseismically designed piers with lap splices need to be retrofitted to resist earthquake induced forces. In addition, it was proven that the proposed retrofitting method can be useful in improving the strength, stiffness, and energy dissipation capacities of bridge piers designed nonseismically. It is thus expected that the proposed method may provide an improved ductility capacity without sudden softening of strength for bridge piers excursing inelastic displacement range.

본 연구에서는, 비내진 설계된 철근콘크리트 교각에 대해 스테인레스강 와이어 메쉬와 고강도 침투성 폴리머 몰탈을 사용한 내진보강 기법을 제안하였다. 본 연구의 목적을 위해, 총 6본의 비내진 설계된 교각 실험체에 대해 반복 가력 실험을 수행하였다. 실험결과, 주철근 겹이음을 갖는 비내진 설계된 교각 실험체에 대한 내진보강이 필요하다는 것을 알 수 있었고, 본 연구에서 제안된 보강 기법은, 비내진 설계된 교각의 강도, 강성 및 에너지 소산능력에 증진 효과가 있음을 알 수 있었다. 또한, 제안된 보강 기법은 비탄성 변위 영역을 경험하는 교각의 강도 저감 완화와 함께 연성도 증진에도 효과가 있을 것으로 기대된다.

Keywords

References

  1. 서울산업대학교 (2005) 격자망 와이어 메쉬와 고강도 침투성 폴리머 몰탈로 보강된 콘크리트 구조물(기둥)의 내진성능평가, 서울산업대학교 건설기술연구소
  2. 염광수, 최상현, 이영호, 이학은 (2005) 강판피복과 CFRP를 이용한 손상된 교각의 내진보수, 한국지진공학회논문집, 한국지진공학회, 제9권 제3호, pp.69-75 https://doi.org/10.5000/EESK.2005.9.3.069
  3. 이대형, 정영수, 이재형, 송호진 (2002) 주철근 겹침이음된 형상비 4.0의 원형 철근콘크리트 교각의 내진성능평가, 대한토목학회논문집, 대한토목학회, 제22권 제 5A호, pp.1193-11202
  4. 이재훈, 손혁수, 고성현 (2004) 축방향철근 연결상세에 따른 철근콘크리트 원형교각의 내진성능, 콘크리트학회논문집, 한국콘크리트학회, 제16권 제2호, pp.249-260 https://doi.org/10.4334/JKCI.2004.16.2.249
  5. 정영수, 박종협, 박희상, 조창백 (2002) 섬유보강 원형 철근콘크리트 교각의 내진성능 향상에 관한 유사동적 실험, 콘크리트학회논문집, 한국콘크리트학회, 제14권 제2호, pp.180-189 https://doi.org/10.4334/JKCI.2002.14.2.180
  6. 정영수, 이대형, 고성현, 이재훈 (2004) 주철근 겹이음된 실물비내진 원형교각의 내진성능 평가, 콘크리트학회 논문집,한국콘크리트학회, 제 16권 제 5호, pp.697-708
  7. Chai, Y.H., Priestley, M.J.N., Seible, F. (1991) Seismic retrofit of circular bridge columns for enhanced flexural performance, ACI Structural Journal, Vol. 88, No. 5, pp.572-584
  8. Priestley, M.J.N., Seible, F., Xiao, Y., Verma, R. (1994a) Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength-Part 1: theoretical considerations and test design, ACI Structural Journal, Vol. 94, No. 4, pp.394-405
  9. Priestley, M.J.N., Seible, F., Xiao, Y., Verma, R. (1994b) Steel jacket retrofitting of reinforced concrete bridge columns for enhanced shear strength-Part 2: test results and comparison with theory, ACI Structural Journal, Vol. 94, No. 4, pp.537-551
  10. Sheikh, S.A. (2002) Performance of concrete structures retrofitted with fibre reinforced polymers, Engineering Structures, Vol. 24, pp.869-879 https://doi.org/10.1016/S0141-0296(02)00025-1
  11. Xiao, Y., Wu, H. (2003) Retrofit of reinforced concrete columns using partially stiffened steel jackets, Joournal of Structural Engineering, ASCE, Vol. 129, No. 6, pp.725-732 https://doi.org/10.1061/(ASCE)0733-9445(2003)129:6(725)