Abstract
In order to develop a new rockfall protection fence using high carbon steel wire rod (HSWR) material instead of the conventional wire rope material, the author has conducted the laboratory strength tests of both materials and their connections, and carried out evaluation of absorbing rockfall energy through the vertical field rockfall tests. The vertical filed rockfall tests showed that the new rockfall protection fence with 12 rows of the HSWR could absorb more rockfall energy than 50 kJ which stands for the typical design criteria. In addition, when the quantity of HSWR was increased up to the 16 rows, the capacity of absorbing energy was greatly improved. The new rockfall protection fence was successfully applied to the highway rock-cut slope. As a result of the filed application, its constructability was similar to the conventional fence, but its total image was improved as simple and clean. The total construction cost was saved up to 20% in comparison with the conventional one.
본 연구는 기존의 낙석방지울타리에 적용되는 와이어로프를 경강선으로 대체하고 소재 및 체결부에 대한 실내성능실험과 더불어 현장에서의 수직낙하시험을 통해 전체적인 에너지 흡수능력을 평가하여 새로운 낙석방지울타리를 개발하는데 있다. 12단 경강선 적용 낙석방지울타리의 수직낙하시험 결과, 국내 낙석방지울타리에 기준으로 적용되는 흡수에너지인 50kJ 이상의 에너지를 흡수하는 것으로 나타났다. 또한 경강선 단수가 12단에서 16단으로 증가함에 따라 에너지 흡수능력도 향상되었다. 이러한 새로운 낙석방지울타리를 도로공사 절취사면 현장에 성공적으로 적용하였다. 그 결과, 시공성은 기존에 비해 별차이가 없는 것으로 나타났으나 미관상 전체적으로 심플하고 깨끗한 이미지를 연출할 수 있었다. 경제성 분석결과에 있어서는 전체 건설비용에 있어 기존 대비 약 20% 정도 절감되는 것으로 나타났다.