DOI QR코드

DOI QR Code

Electrical Lifetime Estimation of a Relay by Accelerated Life Test

가속수명시험을 이용한 릴레이의 전기적 수명예측

  • 김재중 (한양대학교 신뢰성분석연구센터) ;
  • 장석원 (한양대학교 신뢰성분석연구센터) ;
  • 손영갑 (안동대학교 기계공학부)
  • Published : 2008.05.01

Abstract

This paper proposes a way to predict electrical lifetime of a relay using Accelerated Life Testings (ALTs). The relay of interest mounting on printed circuit boards is usually under an inrush current stress. The inrush current is generated and accelerated through controlling a lamp switching device in the ALT. We find that the dominant failure mechanism under high levels of inrush current would be contact welding in the contact surface of the relay and the contact welding process is accelerated according to increase in inrush current. The electrical lifetime model based on Inverse Power Law in term of inrush current is proposed, and parameters characterizing relay's lifetime distribution are statistically estimated using ALTA 6 PRO software.

Keywords

References

  1. Kwon, Y. I. and Han, I. S., 2005, “Mechanical Life Prediction of a Relay By Accelerated Life Tests," Journal of Industrial science researches, Vol. 22, No. 1, pp. 75-78
  2. Lee, J. K., Kim, J. W., Shin, J. C. and Kim, M. S., 2004, "An Accelerated Life Test for Burnout of Tungsten Filament of Incandescent Lamp," The Korean Reliability Society, pp. 129, 134-137
  3. Laurent, M., Nouredine, B. J. and Didier, J., 2000, "Make Arc Erosion and Welding in the Automotive Area," IEEE Trans. on Components and Packaging Technologies, Vol. 23, No. 1, pp. 240-246 https://doi.org/10.1109/6144.846760
  4. Schoepf, Thomas. J. and Franz, H., 2005, "Effects of Different Loads on the Surface of Silver Metal Oxide Contacts for General-purpose Relays," IEEE Trans. on Components and Packaging Technologies, Vol. 28, No. 4, pp. 728-732 https://doi.org/10.1109/TCAPT.2005.859755
  5. Cha, H. Y., Park, Y. S., Kim, J. J., Son, Y. G., Chang, S. W. and Kwack, K. D., 2007, “Mechanical Lifetime Estimation of A Relay using Accelerated Life Testing,” Fall Annual Proceedings of the KSME, pp. 27-34
  6. Leung, C. H. and Anthony, L., 1991, "Contact Erosion in Automotive DC Relays," IEEE Trans. on Components, Hybrids, and Manufacturing Technology, Vol. 28, No. 4, pp. 101-106
  7. ReliaSoft Corporation-Tucson, 2002, "Modeling and Analysis of Time-Dependent Stress Accelerated Life Data," Proceedings Annual Reliability and Maintainability Symposium, pp. 343-348
  8. Nelson, W., 1990, "Accelerated Testing - Statistical Models, Test Plans, and Data Analyses," Wiley, New York
  9. Korea Reliability Technology Service, Inc.

Cited by

  1. S-N Curve Deduction of a KTX High-Speed Train Structure for an Accelerated Life Testing vol.33, pp.4, 2009, https://doi.org/10.3795/KSME-A.2009.33.4.388
  2. Acids generated and influence on electrical lifetime of natural ester impregnated paper insulation vol.25, pp.5, 2018, https://doi.org/10.1109/TDEI.2018.007270