DOI QR코드

DOI QR Code

CSTC of High Strength Steel for ROT Process in Hot Strip Mills

열간압연 ROT에서 고강도강의 CSTC 개발


Abstract

This paper proposes a cooling stop temperature control(CSTC) concept which aims at obtaining the uniform temperature and quality of the material along the longitudinal and lateral direction of the strip. The CSTC is designed using the experimental CCT(Continuous Cooling Transformation), TTT(Time Temperature Transformation) curves and the temperature control model by the heat transfer governing equation, and the temperature control simulator. The cooling pattern and the rolling speed can be solved by the CSTC. It is shown through the field test of the hot strip mill of POSCO that the phase transformation ratio of the high carbon steel is considerably improved by the proposed temperature control.

Keywords

References

  1. M. Phaniraj, S. Shamasundar, and A. K. Lahiri, 'Relevance of ROT control for hot rolled low carbon steels,' Steel Res., vol. 72, no. 5, pp. 221-224, 2001 https://doi.org/10.1002/srin.200100109
  2. W. Timm, K. Weinzierl, A. Leipertz, H. Zieger, and G. Zouhar, 'Modelling of heat transfer in hot strip mill runout table cooling,' Steel Res., vol. 73, no. 3, pp. 97-104, 2002 https://doi.org/10.1002/srin.200200180
  3. M. Suehiro, T. Oda, T. Senuma, and S. Konishi, 'Development of mathematical model for predicting transformation of highcarbon steel during cooling on runout table and its application to on-line temperature control of hot strip mill,' Nippon Steel Technical Report, no. 67, pp.49-56, 1995
  4. T. Oda, Y. Kondo, S. Konishi, H. Murakami, M. Suehiro, and T. Yabuta, 'Development of accurate control in hot strip mill,' The Iron and Steel Institute of Japan, vol. 81, no. 3, pp. 35-40, 1995
  5. N. S. Samaras, 'Novel control structure for runout table coiling temperature control,' AISE Steel Tech., 2001
  6. A. G. Groch, R. Gubernat, and E. R. Birstein, 'Automatic control of laminar flow cooling in continuous and reversing hot strip mills,' Iron and Steel Engineer, vol. 67, no. 9, pp. 16-20, 1990
  7. R. W. Moffat, M. C. Moore, M. J. Robinson, and J. D. Ashton, 'Computer control of hot strip cooling temperature with variable flow laminar sprays,' Iron and Steel Eng., vol. 62, no. 11, pp. 21- 28, 1985
  8. G. V. Ditzhuijzen, 'The controlled cooling of hot rolled strip: a combination of physical modeling, control problems and practical adaptation,' IEEE Trans. on Automatic Control, vol. 38, no. 7, pp. 1060-1065, 1993 https://doi.org/10.1109/9.231460
  9. M. D. Leltholf and J. R. Dahm, 'Model reference control of runout table cooling at LTV,' Iron and Steel Engineer, vol. 66, no. 8, pp. 31-35, 1989
  10. N. S. Samaras and M. A. Simaan, 'Water-cooled end-point boundary temperature control of hot strip via dynamic programming,' IEEE Transactions on Industry Applications, vol. 34, no. 6, pp. 1335-1341, 1998 https://doi.org/10.1109/28.739019
  11. N. S. Samaras and M. A. Simaan, 'Optimized trajectory tracking control of multistage dynamic metal-cooling processes,' IEEE Transactions on Industry Applications, vol. 37, no. 3, pp. 920-927, 2001 https://doi.org/10.1109/28.924776
  12. S. K. Biswas, S. Chen, and A. Satyanarayana, 'Optimal temperature tracking for accelerated cooling processes in hot rolling of steel,' Dynamics and Control, vol. 7, pp. 327-340, 1997 https://doi.org/10.1023/A:1008268310234
  13. T. Harakawa and T. Kawaguchi, 'Digital control in iron and steel making processes,' Automatica, vol. 20, no. 5, pp. 1185-1202, 1993
  14. R. K. Kumar, S. K. Sinha, and A. K. Lahiri, 'An on-line parallel controller for the runout table of hot strip mills,' IEEE Transactions on Control Systems Technology, vol. 9, no. 6, pp. 821-830, 2001 https://doi.org/10.1109/87.960345
  15. S. Guan, H. X. Li, and S. K. Tso, 'Multivariable fuzzy supervisory control for the laminar cooling process of hot rolled slab,' IEEE Transactions on Control Systems Technology, vol. 9, no. 2, pp. 348-356, 2001 https://doi.org/10.1109/87.911386
  16. F. E. James et al., 'Numerical modeling of hot strip mill runout table cooling,' Iron Steel Eng., pp. 50-55, 1993
  17. N. Hatta and H. Osakabe, 'Numerical modeling for cooling process of a moving hot plate by a laminar water curtain,' The Iron and Steel Institute of Japan, vol. 29, no. 11, pp. 919-925, 1989 https://doi.org/10.2355/isijinternational.29.919
  18. D. Auzinger, F. Parzer, 'Process optimization for laminar cooling,' MPT International, vol. 5, pp. 68-75, 1996
  19. E. N. Hinrichsen and G. P. Petrus, 'Hot strip mill runout table cooling - a system view of control, operation and equipment,' Iron and Steel Eng., vol. 53, no. 10, pp. 29-34, 1976
  20. K. Yanagi, 'Prediction of strip temperature for hot strip mills,' The Iron and Steel Institute of Japan, vol. 16, no. 1, pp. 11-19, 1976
  21. V. S. Arpaci, Conduction Heat Transfer, Lexington, MA, 1991
  22. V. Ginzburg, Steel Rolling Technology, New York, Marcel Dekker, 1988
  23. H. Yoshida, A. Yorifuji, S. Koseki, and M. Saeki, 'An integrated mathematical simulation of temperatures, rolling loads and metallurgical properties in hot strip mills,' The Iron and Steel Institute of Japan, vol. 31, no. 6, pp. 571-576, 1991 https://doi.org/10.2355/isijinternational.31.571

Cited by

  1. Independent Cooling Controller for Temperature Control of High Strength and Atmosphere Corrosion Resisting Steel in Hot Strip Mills vol.39, pp.3, 2015, https://doi.org/10.3795/KSME-A.2015.39.3.327