DOI QR코드

DOI QR Code

Event Transmission of Respiratory rate and Heart rate Measured on Wheelchair

휠체어에서 호흡수와 심박수 측정 및 이벤트 전송

  • Han, Dong-Kyoon (Dept. of Biomedical Engineering, School of Medicine, Chungbuk National University) ;
  • Kim, Jong-Myoung (Dept. of Biomedical Engineering, School of Medicine, Chungbuk National University) ;
  • Hong, Joo-Hyun (Dept. of Biomedical Engineering, School of Medicine, Chungbuk National University) ;
  • Cha, Eun-Jong (Dept. of Biomedical Engineering, School of Medicine, Chungbuk National University) ;
  • Lee, Tae-Soo (Dept. of Biomedical Engineering, School of Medicine, Chungbuk National University)
  • 한동균 (충북대학교 의과대학 의공학교실) ;
  • 김종명 (충북대학교 의과대학 의공학교실) ;
  • 홍주현 (충북대학교 의과대학 의공학교실) ;
  • 차은종 (충북대학교 의과대학 의공학교실) ;
  • 이태수 (충북대학교 의과대학 의공학교실)
  • Published : 2008.12.31

Abstract

The purpose of this study is to measure both ECG and BCG(Ballistocariograph) signal of a subject on moving or resting wheelchair and detect the heart rate and respiratory rate and transmit an event message to remote server on emergent situation. To acquire ECG and BCG data, amplifier circuits were composed to be suitable for their characteristics. The output signals were converted to digital data and stored in bio-signal archiving media(SD card). CDMA module was used to transmit the event data on ECG electrode detachment and the received data was monitored by the developed C# application program. 5 volunteers participated in the experiment to evaluate the validity of the developed device. When the event occurs in each subject, 48 Kbyte data, stored for 32 seconds from that point, was transmitted to remote server through CDMA cellular phone network correctly. The received data of ECG, BCG, and 3-axial acceleration could be archived in server and the heart rate and respiratory rate could be measured and analyzed. The developed device in this study could acquire the ECG and BCG data of subjects on wheelchair simultaneously and measure their heart rate and respiratory rate. In addition, event data was verified to be transmitted to remote server without any errors.

Keywords

References

  1. Fensli R, Gunnarson E, Hejlesen O. "A wireless ECG system for continuous event recording and communication to a clinical alarm station" Proceedings of the 26th Annual International Conference of the IEEE EMBS 2004, pp.2208-11
  2. Hernandez AI, Mora F, Villegas G, Passariello G, Carrault G. "Real-time ECG transmission via internet for nonclinical applications". IEEE Transactions on Biomedical Engineering, vol. 5 no. 3, pp.253-7, 2001 https://doi.org/10.1109/4233.945297
  3. Jovanov E, Lords AO, Raskovic D, Cox PG, Adhami R, Andrasik F. "Stress monitoring using a distributed wireless intelligent sensor system". IEEE Engineering in medicine and biology magazine, vol. 22, no. 3, pp.49-55, 2003
  4. Hong JH, Kim NJ, Cha EJ, Lee TS. "Zigbee based photoplethysmography". Journal of Korea Intellectual Patent Society, vol. 8, no. 3, pp.31-5, 2006
  5. Lee JS, No MH, Yong JH, Kim DH, Kim JH. Human physiology. JungDam Publishers, 2002. pp.295-7
  6. Hong JH. "Wireless 3 channel ECG monitoring system for ubiquitous healthcare" [dissertation]. Chungbuk. Chungbuk National University. 2008
  7. Starr I. "Further clinical studies with the ballistocardiograph on abnormal form, on digitalis action, in thyroid disease, and in coronary heart disease". Transaction of the Association of American Physicians, vol. 59, pp.180-9, 1946
  8. Yu X, Dent D. "Neural networks in ballistocardiography(BCG) using FPGAs". in IEE Colloquium on Software Support and CAD Techniques for FPGAs. 1994, pp.7/1-5
  9. Baker BM, Scarborough WR, Mason RE, et al. "Coronary artery disease studied by ballistocardiography:a comparison of abnormal ballistocardiograms and electrocardiograms". Transactions of the American Clinical and Climatological Association, vol. 62, pp.191,1950
  10. Kim JM, Hong JH, Kim NJ, Cha EJ, Lee TS. "Two algorithms for detecting respiratory rate from ECG signal". in Proc. of World Congress on Medical Physics and Biomedical Engineering, 2006, pp.54
  11. Jung DK, Kim KN, Yeon KS, Choi BC, Suh DJ. "Detection of radial pulse wave by photoplethysmogram" Korean Journal of Life Science, vol. 13, no. 1, pp.42-6, 2003 https://doi.org/10.5352/JLS.2003.13.1.042
  12. Murthy R. Pavlidis I. "Non-contact monitoring of breathing function using infrared imaging". Technical Report UH-CS-05 -09, Computer Science Department. University of Houston 2005, April 9
  13. Lee IK, Choi SS, Kim SS, Kim KA, Lee TS, Cha EJ. "Tidal volume estimation by wireless respiration monitor with belt-type transducer in patient's pants". in Proc. of The Korea Society of Medical &Biological Engineering Conference 2007, pp.14-7
  14. Caggiano D, Reisman S. "Respiration derived from electrocardiogram: a quantitative comparison of three different methods". Proc. of the IEEE twenty-second annual international conference, 1996, pp.103- 4