Leaching of copper from waste PCBs with electro-generated chlorine -Analysis of experimental factors on the leaching by the factorial design-

전해생성염소(電解生成鹽素)에 의한 폐인쇄회로기판(廢印刷回路基板)으로부터 구리 침출(浸出) -실험계획법(實驗計劃法) 적용(適用)에 의한 침출(浸出) 영향인자(影響因子)의 분석(分析)-

  • Kim, Eun-Young (Resources Recycling, University of Science & Technology) ;
  • Lee, Jae-Chun (Metal recovery group, Korea Institute of Geoscience & Mineral Resources) ;
  • Kim, Min-Seuk (Metal recovery group, Korea Institute of Geoscience & Mineral Resources) ;
  • Jung, Jin-Ki (Metal recovery group, Korea Institute of Geoscience & Mineral Resources) ;
  • Yoo, Kyoung-Keun (Metal recovery group, Korea Institute of Geoscience & Mineral Resources)
  • 김은영 (과학기술연합대학원대학교 자원순환공학) ;
  • 이재천 (한국지질자원연구원 금속회수연구실) ;
  • 김민석 (한국지질자원연구원 금속회수연구실) ;
  • 정진기 (한국지질자원연구원 금속회수연구실) ;
  • 유경근 (한국지질자원연구원 금속회수연구실)
  • Published : 2008.12.27

Abstract

The leaching of Cu from waste PCBs was investigated with electro-generated chlorine as an oxidant. The leaching experiments were carried out according to the design of experiments to analyze quantitatively the effect of parameters on copper leaching. From the analysis of variance (ANOVA) it was suggested that the effective parameters were current density, temperature, concentration of HCl, and the interaction between the concentration of HCl and temperature. Especially, the effect of current density was analyzed to contribute to the interpretation of result for copper leaching up to 95.7%. A multiple regression model obtained from the analysis of effective parameters explained 99% of leaching results. From the model equation, it was found that the effect of HCl concentration on copper leaching increased with temperature.

전해생성염소를 산화제로 사용하여 폐인쇄회로기판으로부터 구리의 침출에 대한 연구를 수행하였다. 구리침출반응과 관련된 실험인자들의 영향을 정량적으로 파악하기 위하여 실험계획법을 적용하였다. 실험결과의 분산분석으로부터 전류밀도, 침출온도, 염산농도 그리고 침출온도와 염산농도의 교호작용 등이 구리침출에 유효한 인자로 나타났다. 이들 중 구리침출에 가장 큰 영향을 미치는 인자는 침출실험 결과해석의 95.7%출 차지하는 전류밀도로 분석되었다. 실험결과의 중회귀분석을 이용하여 침출실험 결과의 99%를 설명할 수 있는 침출 모델식을 얻었다. 또한 모델식을 통한 구리 등침출선의 예측으로부터 침출온도가 높아질수록 구리침출량의 증가에 대한 염산농도의 영향이 커지는 것을 알 수 있었다.

Keywords

References

  1. Schlummer, M. et al., 2007 : Characterisation of polymer fractions from waste electrical and electronic equipment (WEEE) and implicatios for waste management, Chemosphere, 67, pp. 1866-1876 https://doi.org/10.1016/j.chemosphere.2006.05.077
  2. Cui, J. and Forssberg, E., 2003 : Mechanical recycling of waste electric and electronic equipment: a review, Journal of Hazardous Materials, B29, pp. 243-263
  3. 엄형순 외, 2006 : 부품 재사용여부에 따른 폐컴퓨터에 대한 전과정 평가(LCA), 대한환경공학회지, 28(5), pp. 494-500
  4. 장용철 외, 2008 : 폐휴대폰 발생량 산정, 수거 및 유통체계, 한국폐기물학회지, 25, pp. 82-89
  5. Chris Y. Y. et al, 2007 : Experimental studies on cryogenic recycling of printed circuit board, Int J. Adv. Manuf. Technol., 34, pp.657-666 https://doi.org/10.1007/s00170-006-0634-z
  6. Cui, J. and Zhang, L., 2008 : Metallurgical recovery of metals from electronic waste: A review, Journal of Hazardous Materials, in press
  7. Mecucci, A., and Scott, K., 2002 : Leaching and electrochemical recovery of copper, lead and tin from scrap printed circuit boards, J.Chem.Technol.Biotechnol., 77, pp.449-457 https://doi.org/10.1002/jctb.575
  8. Pilone, D. and Kelsall, G. H., 2006 : Prediction and measurement of multi-metal electrodepostion rates and efficiencies in aqueous acidic chloride media, Electrochim. Acta, 51, pp.3802-3808 https://doi.org/10.1016/j.electacta.2005.10.045
  9. Veit, H. M. et al., 2006 : Recovery of copper from printed circuit boards scraps by mechanical processing and electrometallurgy, Journal of Hazardous Materials, B137, pp. 1704-1709
  10. 김은영 외, 2006 : 전해생성된 염소에 의한 구리의 침출거동, 자원리싸이클링학회지, 15(6), pp. 33-40
  11. Kim, E.-Y. et al., 2008 : Effect of cuprous ions on Cu leaching in the recycling of waste PCBs, using electrogenerated chlorine in hydrochloric acid solution, Mineral Engineering, 21, pp. 121-128 https://doi.org/10.1016/j.mineng.2007.10.008
  12. Moore, J. J. et al., 1981 : "Chemical metallurgy", pp. 115-123, Butterworths, London, UK
  13. Herreros, O. et al., 1999 : Dissolution kinetics of copper, white metal and natural chalcocite in Cl2/Cl- media, Hydrometallurgy, 51, pp. 345-357 https://doi.org/10.1016/S0304-386X(98)00085-1
  14. Herreros, O. et al., 2005 : Dissolution kinetics of metallic copper with $CuSO_4-NaCl-HCl$, Hydrometallurgy, 77, pp. 183-190 https://doi.org/10.1016/j.hydromet.2004.11.010
  15. 박성현, 1998 : "현대실험계획법", pp. 12, 247-304, 민영사, 서울, 한국
  16. 김민석 외, 2004 : 實驗計劃法을 적용한 ZnO의 $NH_4Cl$ 浸出 硏究, 한국지구시스템공학학회지, 41(5), pp. 354-363
  17. Kolthoff, I. M. et al., 1971 : "Quantitative chemical analysis", pp. 842-860, The Macmilan company, New York, USA
  18. Russell, L., 1989 : Quick and easy analysis of unreplicated factorials, Technometrics, 11, pp. 469
  19. Vinals, J., Oliveras, J., and Nunez, C., 1986 : Leaching kinetics of natural cobalt triasenide in chlorine soutions, Metallurgical Transactions B, 17B, pp. 629-637
  20. Fritz, J. J., 1982 : Solubility of cuprous chloride in various soluble aqueous chlorides, Journal of chemical and engineering data, 27(2), pp. 188-193 https://doi.org/10.1021/je00028a027