DOI QR코드

DOI QR Code

Determination of Trace Elements of Ge and P in a Gold Bonding Wire by Inductively Coupled Plasma Atomic Emission Spectrometry

  • Choi, Sung-Min (Department of Chemistry, Chungnam National University) ;
  • Lee, Gae-Ho (Department of Chemistry, Chungnam National University) ;
  • Han, Jae-Kil (Department of Surface & Nano Technology)
  • Published : 2008.02.20

Abstract

Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used to determine the presence of germanium and phosphorus in a pure gold bonding wire. The samples were dissolved with hydrobromic acid and nitric acid at room temperature. The quantitation limits were 0.012 mg L-1 at 265.118 nm for Ge and 0.009 mg L-1 at 177.495 nm for P. Using the mixed acid digestion formula of DIW+HBr+HNO3, the recoveries were in the range of 98-100% and the relative standard deviation was within 1.1-2.3%. On the other hand, the amount of Ge decreased by about 16.2% using DIW+HCl+HNO3, due to the formation of a volatile compound. The Ge contents determined using the external method and the standard addition method were 9.45 mg kg-1 and 9.24 mg kg-1, respectively, and the P contents, using the same methods, were 22.49 mg kg-1 and 23.09 mg kg-1, respectively. Both methods were successfully used to determine the trace amounts of P and Ge in the pure gold bonding wire samples.

Keywords

References

  1. Saiki, H.; Marumo, Y.; Nishitake, H.; Uemura, T.; Yotsumoto, T. J. Mater. Process Tech. 2006, 177, 709 https://doi.org/10.1016/j.jmatprotec.2006.04.024
  2. Chew, Y. H.; Wong, C. C.; Breach, C. D.; Wulff, F.; Mhaisalkar, S. J. Alloy Compd. 2006, 415, 193 https://doi.org/10.1016/j.jallcom.2005.08.020
  3. Kim, K. S.; Song, J. Y.; Chung, E. K.; Park, J. K.; Hong, S. H. Mech. Mater. 2006, 38, 119 https://doi.org/10.1016/j.mechmat.2005.05.015
  4. Chew, Y. H.; Wong, C. C.; Breach, C. D.; Wulff, F.; Mhaisalkar, S. G.; Pang, C. I.; Saraswati. Thin Solid Films 2004, 462-463, 346 https://doi.org/10.1016/j.tsf.2004.05.079
  5. Saraswati, T. S.; Sritharan, T.; Pang, C. I.; Chew, Y. H.; Breach, C. D.; Wulff, F.; Mhaisalkar, S. G.; Wong, C. C. Thin Solid Films 2004, 462-463, 351 https://doi.org/10.1016/j.tsf.2004.05.032
  6. Berlicki, T. M.; Murawski, E.; Muszynski, M.; Osadnik, S. J.; Prociow, E. L. Sensor Actuat. A 1995, 50, 183 https://doi.org/10.1016/0924-4247(96)80106-3
  7. Graham, S. M.; Robert, R. V. D. Talanta 1994, 41, 1369 https://doi.org/10.1016/0039-9140(94)E0027-O
  8. Profrock, D.; Leonhard, P.; Wilbur, S.; Prange, A. J. Anal. At. Spectrom. 2004, 19, 623 https://doi.org/10.1039/b310530j
  9. Karadjova, I.; Arpadjan, S.; Jordanova, L. Fresen. J. Anal. Chem. 2000, 367, 146 https://doi.org/10.1007/s002160051615
  10. Hinds, M. W.; Kogan, V. V. J. Anal. At. Spectrom. 1994, 9, 451 https://doi.org/10.1039/ja9940900451
  11. Becotte-Haigh, P.; Tyson, J. F.; Denoyer, E.; Hinds, M. W. Spectrochim Acta B 1996, 51, 1823 https://doi.org/10.1016/S0584-8547(96)01535-2
  12. Meeravali, N. N.; Reddy, M. A.; Kumar, S. J. Spectrochim Acta B 2007, 62, 504 https://doi.org/10.1016/j.sab.2007.04.017
  13. Daskalova, N.; Velichkov, S.; Slavova, P.; Ivanova, E.; Aleksieva, L. Spectrochim Acta B 1997, 52, 257 https://doi.org/10.1016/S0584-8547(96)01591-1
  14. Walters, F. H.; Jr, L. P. Sequential Simplex Optimization; CRC press LLC: Florida, 1991
  15. Ebdon, L.; Evans, E. H.; Barnett, N. W. J. Anal. At. Spectrom. 1989, 4, 505 https://doi.org/10.1039/ja9890400505
  16. Ellison, S. L. R.; Rosslein, M.; Williams, A. EURACHEM/CITAC Guide Quantifying Uncertainty in Analytical Measurement, 2nd ed; EURACHEM: England (UK), 2000

Cited by

  1. Determination of Ge in Au alloys using sodium hypophosphite and potassium iodate potentiometric titration method pp.1867-7185, 2014, https://doi.org/10.1007/s12598-014-0375-3
  2. Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials vol.24, pp.12, 2009, https://doi.org/10.1039/b920784h
  3. Determination of trace elements in high purity gold by high resolution inductively coupled plasma mass spectrometry vol.24, pp.4, 2009, https://doi.org/10.1007/s11595-009-4608-5