References
- Lausmaa J. Surface spectroscopic characterization of titanium implant materials. Journal of Electron Spectroscopy and Related Phenomena 1996;81:343-361 https://doi.org/10.1016/0368-2048(95)02530-8
- Eisenbarth E, Velten D, Schenk-Meuser K et al. Interactions between cells and titanium surfaces. Biomolecular Engineering 2002;19:243-249 https://doi.org/10.1016/S1389-0344(02)00032-1
- Sul YT. The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant. Biomaterials 2003;24:3893-3907 https://doi.org/10.1016/S0142-9612(03)00261-8
- Aubin JE, Liu F, Malaval L, Gupta AK. Osteoblast and chondroblast differentiation. Bone 17 (Suppl.) 1995;77-83 https://doi.org/10.1016/8756-3282(95)00183-E
- Albreksson T, Brӓnemark PI, Hansson HA and Lindstom J. Osseointegrated titanium implants. Acta Orthop Scand 1981;52:155-170 https://doi.org/10.3109/17453678108991776
- Jaffin RA and Berman CL. The excessive loss of figure fixtures in type IV bone : a 5-year analysis. J Periodontol 1991;62:2-4 https://doi.org/10.1902/jop.1991.62.1.2
- Jemt T. Implant treatment in resorbed edentulous upper jaw. A three-year follow-up study in 70 patients. Clin Oral Impl Res 1993;4:187-194 https://doi.org/10.1034/j.1600-0501.1993.040404.x
- Jemt T, Chai J, Harnett J et al. A 5-year prospective multi-center follow-up report on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants 1996;11:291-298
- Wennerberg A. The importance of surface roughness for implant incorporation. International Journal of Machine Tools and Manufacturing 1998;38:657-662 https://doi.org/10.1016/S0890-6955(97)00114-4
- Testori T, Wiseman L, Woolfe S, Porter SS. A prospective multicenter clinical study of the osseotite implant: four-year interim report. Int J Oral Maxillofac Implants 2001;16: 193-200
- Bowers KT, Keller JC, Randolph BA, Wick DG, Michaels CM. Optimization of surface micromorphology for enhanced osteoblast response in vitro. Int J Oral Maxillofac Implants 1992;7(3):302-310
- Lohmann CH, Sagun R Jr, Sylvia VL et al. Surface roughness modulates the response of MG63 osteoblast-like cells to 1,25-(OH)2D3 through regulation of phospholipase A2 activity and activation of protein kinase A. J Biomed Mater Res 1999;47:139-151 https://doi.org/10.1002/(SICI)1097-4636(199911)47:2<139::AID-JBM4>3.0.CO;2-2
- Ericsson I, Johansson CB, Bystedt H, Norton MR. A histomorphometric evaluation of bone-to-implant contact on machine prepared and roughened titanium dental implants. A pilot study in the dog. Clin Oral Implants Res 1994;5: 202-206 https://doi.org/10.1034/j.1600-0501.1994.050402.x
- Larsson C, Thomsen P, Lausmaa J et al. Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morpholohy. Biomaterials 1994;15:1062-1074 https://doi.org/10.1016/0142-9612(94)90092-2
- Schneider G, Burridge K. Formation of focal adhesions by osteoblasts adhering to different substrata. Experimental Cell Research 1994;214:264-269 https://doi.org/10.1006/excr.1994.1257
- Stanford CM, Keller JC, Solursh M. Bone cell expression on titanium surfaces is altered by sterilization treatments. Journal of Dental Research 1994;73:1061-1071 https://doi.org/10.1177/00220345940730050801
- Stanford CM, Brand RA. Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling. Journal of Prosthetic Dentistry 1999;81:553-561 https://doi.org/10.1016/S0022-3913(99)70209-X
- Branemark PI, Zarb GA, Albreksson T. Tissue integrated prosthesis. Osseointegration in clinical dentistry. Chicago: Quintessence Publishing Co. Inc. 1985
- Gottlander M, Albrektsson T. Histomorphometric studies of hydroxyapatite coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants 1991;6: 399-404
- Gottlander M, Albrektsson T. A Histomorphometric study of unthreaded hydroxyapatite coated and titanium coated implants in rabbit bone. Int J Oral Maxillofac Implants 1992;7:485-490
- Denissen HW, Kalk W, Nieuport HM, Maltha JC, Hoofe A. Mandibular bone response to plama-sprayed coatings of hydroxyapatite. Int J Prosthodont 1990;3:53-58
- Oonishi H, Yamamoto M, Ishimura H et al. The Effect of Hydroxyapatite coating on Bone Growth into porous titanium alloy implants. J Bone Joint Surg 1989;71:213-216
- Hulshoff JEG, Hayakawa T, van Dijk K et al. Mechanical and histological evaluation of Ca-P plasma-spray and magnetron sputter-coated implants in trabecular bone of the goats. J Biomed Meter Res 1997;36:75-83 https://doi.org/10.1002/(SICI)1097-4636(199707)36:1<75::AID-JBM9>3.0.CO;2-I
- Cheng Yang, Wuhan. The effect of calcium phosphate implant coating on osteoconduction. Oral Sug Oral Med Oral Pathol Oral Radiol Endod 2001;92:606-609 https://doi.org/10.1067/moe.2001.118477
- Schroeder A, Pohler O, Sutter F. Gewebereaktion auf ein Titan-Hohlzylin-derim-platat mit Titan-Spritzschichtoberflache. Schweiz Monatsschr Zahnheilkd 1976;86:713-727
- Babbush CA, Kent JN, Misiek DJ. Titanium plasma-sprayed(TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg 1986;44: 274-282 https://doi.org/10.1016/0278-2391(86)90078-9
- Chang YL, Lew D, Park JB, Keller JC. Biomechanical and morphometric analysis of hydroxyapatite-coated implants with varying crystallinity. J Oral Maxillofac Surgery 1999;57:1096-1108 https://doi.org/10.1016/S0278-2391(99)90333-6
- Vercaigne S, Wolke JGC, Naert I, Jansen JA. A histological evaluation of TiO2 grit blasted and Ca-P magnetron sputtered coated implants placed in the trabecular bone of the goat: part 2. Clinical Oral Implants Research 2000;11: 314-324 https://doi.org/10.1034/j.1600-0501.2000.011004314.x
- Jones FH. Teeth and bones: applications of surface science to dental materials and related biomaterials. Surface Science Reports 2001;42:75-205 https://doi.org/10.1016/S0167-5729(00)00011-X
- Sul YT, Johansson CB, Jeong Y, Albrektsson T. The electrochemical oxide growth behavior on titanium in acid and alkaline electrolytes. Medical Engineering and Physics 2001;23:329-346 https://doi.org/10.1016/S1350-4533(01)00050-9