Abstract
National Geographic Information Institute has installed the first permanent Global Positioning System (GPS) station SUWN in 1995 and, as of today, the number of sites is 14. In this study, we visited all the 14 stations and determined if the site mount and antenna configuration conforms to the international site guidelines published by International GNSS Service and National Geodetic Survey. The environment around each station was also checked for the possibility of causing positioning errors. In addition, the GPS data quality was evaluated using the quality-checking program called TEQC. As a result of site visits, we found that low stations (TABK, CHJU, KWNJ, and WNJU) have unfavorable environment and TEQC results validated it. TEQC results also showed that the GPS receiver change during years 2005-2006 reduced the multipath errors and the number of cycle slips at every station.
국토지리정보원은 1995년 수원 관측소 설치를 시작으로 현재 14개소의 GPS 상시관측소를 운영하고 있다. 이 연구에서는 14개 관측소를 모두 방문하고 IGS와 NGS의 사이트 가이드라인에 적합한 안테나와 지지대를 유지하고 있는지, 그리고 관측소 주변 환경으로 인해 측위오차가 발생할 가능성이 있는지를 조사하였다. 또한 현장조사 결과를 TEQC 프로그램을 이용한 GPS 데이터 품질평가 결과와 비교하였다. 현장조사 결과 태백, 제주, 광주, 그리고 원주 관측소의 관측환경은 충분한 시야각이 확보되지 않고 다중경로 오차 유발 요인이 다수 존재하는 등의 문제점이 있음을 파악하였고, 이는 TEQC 품질평가를 통해서도 입증되었다. 그리고 2005-2006년 사이에 진행된 GPS 수신기 교체에 의해 국토지리정보원 GPS 상시관측소의 다중경로 오차와 사이클슬립 개수가 감소되었음을 발견하였다.